| Plan Review Stops For Permit 14080586 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-11-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-11-05 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-11-05 |
Time |
18:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-10-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-10-24 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-10-24 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2014-10-24 16:54:01 | RESIDENTIAL (R3) ADDITION/ALTERATION, SECOND BUILDING | | | REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- NEED TO PROVIDE TWO COMPLETE SET OF DRAWINGS. ONE | | | SET OF DRAWINGS SUBMITTED IS MISSING THE STRUCTURAL | | | DRAWINGS S1 THRU S4. SEC. 107.1 CITY AMENDMENTS TO FBC. | | | | | | 2- PROVIDE 2 COPIES OF THE ESR 1826 ICYNENE EVALUATION | | | REPORT TO VERIFY COMPLIANCE WITH SEC. R316. | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR ALL SIMPSON STRUCTURAL CONNECTORS | | | SPECIFIED ON PLANS AND DETAILS. PROVIDE ONLY THE | | | PRODUCT APPROVAL COVER PAGE AND PAGE SHOWING THE | | | SPECIFIED CONNECTOR OR WRITE DOWN THE PRODUCT APPROVAL | | | NUMBER NEXT TO EACH SPECIFIED CONNECTOR. (REPEAT | | | COMMENT). | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-09-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-09-11 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-09-11 |
Time |
18:35 |
Sent To |
|
|
| Notes |
| 2014-09-11 19:00:07 | RESIDENTIAL (R3) ADDITION/ALTERATION, BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- BOTH SET OF PLANS SUBMITTED NEED TO BE SIGNED AND | | | SEALED BY THE ARCHITECT OF RECORD AS REQUIRED BY | | | CHAPTER 481 FLORIDA STATUTES. | | | ***NOTE: MAKE SURE BOTH SETS ARE THE SAME. ONE SET | | | SUBMITTED WAS DATED 05/15/2014 AND THE OTHER ONE WAS | | | DATED 07/01/2014. COORDINATE THE DRAWINGS BEFORE | | | RE-SUBMITTAL TO AVOID CONFLICTS AND DELAYS. | | | | | | 2- BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT | | | FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY | | | OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY | | | IMPACT FEE ORDINANCE OF THE LAND DEVELOPMENT CODE. | | | | | | 3- SHEET SP-1: | | | A) NOTE REGARDING THE EXISTING BUILDING ALTERATION | | | LEVEL IS INCOMPLETE. COMPLETE THE ALTERATION LEVEL | | | INFORMATION AND ALSO KEEP IN MIND THAT THIS IS AN | | | ADDITION ALSO. SEC. 401.4 OF 2010 FBC-EXISTING BUILDING | | | | | | B) FIRE DEPARTMENT NOTES AND REFERENCED CODE SECTIONS | | | DON'T APPLY TO SINGLE FAMILY RESIDENCES. THESE NOTES | | | ARE NOT NEED IT. REVISE AS REQUIRED. SEC. 107.2.1 CITY | | | AMENDMENTS TO FBC. | | | | | | 4- NEW MASTER BEDROOM EGRESS WINDOWS: PROVIDE | | | MANUFACTURERS CUT SHEETS SHOWING SIZES SPECIFIED IN | | | PLANS TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS | | | OF SEC. R310 OF 2010 FBC-RESIDENTIAL. | | | | | | 5- PROVIDE ICYNENE EVALUATION REPORT TO SHOW COMPLIANCE | | | WITH SEC. R316. | | | | | | 6- SHEET S4: | | | A) PROVIDE COMPLETE SPECIFICATIONS FOR THE TYPE OF | | | SECOND FLOOR SHEATHING AND ROOF SHEATHING. THERE IS NO | | | INFORMATION ON PLANS. SEC. R301 OF 2010 | | | FBC-RESIDENTIAL. | | | | | | B) ROOF SHEATHING NAILS NEED TO BE RING SHANK NAILS AS | | | REQUIRED BY SEC. R803.2.3.1 OF 2010 FBC-RESIDENTIAL. | | | CLEARLY INDICATE THAT NAILS NEED TO BE RING SHANK | | | NAILS. | | | | | | 7- A) DESIGN PROFESSIONAL TO CLEARLY SPECIFY ON PLANS | | | TYPE OF ROOFING SYSTEM, MATERIALS AND FASTENING AS | | | REQUIRED BY SEC. 107.2.1.2 OF CITY AMENDMENTS TO FBC. | | | (NOTE: IF USING FOAM ADHESIVE FOR TILE INSTALLATION, | | | THEN, CLEARLY IDENTIFY ON TABLE 3A-2 OF FLORIDA PRODUCT | | | APPROVAL FL7804-R7 SUBMITTED WHICH ADHESIVE IS GOING TO | | | BE USED TO VERIFY COMPLIANCE WITH THE ATTACHMENT | | | RESISTANCE). | | | | | | B) PRODUCT APPROVAL FL14317-R5 ROOFING UNDERLAYMENT | | | SUBMITTED MAY NOT BE USED. DESIGN PRESSURES SHOWN ON | | | LIMITATION 5.5.2 THRU 5.5.2.3 DON'T MEET THE REQUIRED | | | DESIGN PRESSURES OF SEC. R301. NEED TO USE ANOTHER | | | PRODUCT. AND, COORDINATE WITH ITEMS #6(C) AND #7(A) | | | ABOVE. | | | | | | C) PRODUCT APPROVAL FL11915-R3 SUBMITTED. CLEARLY | | | SPECIFY WHICH SPECIFIC UNDERLAYMENT IS GOING TO BE | | | USED. COORDINATE WITH DESIGN PROFESSIONAL | | | SPECIFICATIONS REQUIRED BY ITEM # 7(A) ABOVE. | | | | | | 8- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS | | | FOR THE INSTALLATION OF THE ROUND WINDOW AS SPECIFIED | | | ON PLANS. SEC. R612.10.2 OF 2010 FBC-RESIDENTIAL. | | | | | | 9- PROVIDE PROVIDE PRODUCT APPROVAL (2 COPIES) AS | | | REQUIRED BY DCA RULE 9N-3 FOR: | | | A) ROOF TILE UNDERLAYMENT IF USING SELF ADHERING | | | UNDERLAYMENT. FLORIDA PRODUCT APPROVAL FL14317-R5 | | | SUBMITTED CAN'T BE USED. SEE ITEM #7(B) ABOVE. | | | | | | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON ALL | | | DETAILS/ SECTIONS AND SPECIFICATIONS. (NOTE: PROVIDE | | | ONLY THE PRODUCT APPROVAL COVER PAGE AND PAGE SHOWING | | | THE CONNECTOR OR WRITE DOWN THE PRODUCT APPROVAL NUMBER | | | NEXT TO THE SPECIFIED STRUCTURAL CONNECTORS IN ALL | | | DETAILS). | | | | | | 10- DESIGN PROFESSIONAL OF RECORD TO REVIEW AND APPROVE | | | IN WRITING (NOT SIGNING AND SEALING) ALL PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | TO FBC. | | | | | | ***NOTES: | | | *** PROVIDE RESPONSE LETTER ADDRESSING EACH COMMENT TO | | | EXPEDITE THE REVIEW PROCESS. | | | *** PLEASE REMOVE AND REPLACE ANY REVISED SHEET WHEN | | | RE-SUBMITTING TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-11-03 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-03 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-03 |
Time |
08:47 |
Sent To |
B |
|
| Notes |
| 2014-11-03 12:55:22 | TO JG'S DESK. | | | | | | | | 2014-11-03 12:14:23 | DATE: 11/3/2014 | | | PROJECT: BARCELONA RD RENNOVATION | | | PERMIT#: 14080856 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 3RD ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) INDICATE THE LOCATION FOR THE ELECTRICAL PANELS. | | | 2010 WPB AMENDMENTS TO THE FBC107.3.5 | | | | | | 2) REVISE PANEL SCHEDULE "A" TO CORRECT PROBABLE TYPO | | | FOR "KITCHEN" CIRCUIT #23 INDICATING A SINGLE POLE | | | 60AMP OCPD WITH #6 WIRE. | | | WHICH 110V 1POLE CIRCUIT IS IDENTIFIED AS "KITCHEN"? | | | PLEASE CLARIFY BY INDICATING CIRCUIT NUMBERS ON THE | | | FLOOR PLAN TO CORRESPOND TO CIRCUIT NUMBERS ON THE | | | PANEL SCHEDULES. | | | | | | 3) REVISE THE RISER DIAGRAM AN VERIFY THE METAL NATURAL | | | GAS PIPING BE BONDED IN ACCORDANCE WITH THE NEC | | | 250.104(B) | | | | | | 4) VERIFY THE ELECTRICAL SERVICE DISCONNECTING MEANS | | | HAS A FAULT CURRENT RATING THAT IS SUFFICIENT AT | | | NOMINAL CIRCUIT VOLTAGE FOR THE CURRENT THAT MUST BE | | | INTERRUPTED. NEC 110.9 | | | | | | 5) VERIFY LUMINAIRES AND EXHAUST FANS LOCATED IN THE | | | BATHROOMS OVER BATHTUB OR SHOWER SHALL BE IN ACCORDANCE | | | WITH THE NEC 410.10(D) BATHTUB AND SHOWER, AND | | | NEC110.3(B) LISTING AND LABELING | | | | | | 6) VERIFY ALL RECEPTACLE OUTLETS INSTALLED THROUGHOUT | | | THE HOUSE SHALL BE INSTALLED IN COMPLIANCE WITH NEC | | | 210.52(A)(1) SHALL BE INSTALLED SUCH THAT NO POINT | | | MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY WALL | | | SPACE IS MORE THAN (6 FT) FROM A RECEPTACLE OUTLET. | | | | | | 7) A GFI OUTLET SHALL BE INSTALLED AT EACH COUNTERTOP | | | SPACE THAT IS 12" OR WIDER. GFI OUTLETS SHALL BE | | | INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE | | | THAN 24" HORIZONTALLY FROM AN OUTLET IN THAT SPACE. NEC | | | 210.52(C)(1). THERE APPEAR TO BE ADDITIONAL OUTLETS | | | REQUIRED AT COUNTERTOP WALL SPACE AREAS IN THE KITCHEN. | | | | | | 8) ALL 125V SINGLE PHASE, 15 AND 20AMP RECEPTACLES | | | INSTALLED IN THE LOCATIONS SPECIFIED IN (1) THROUGH (8) | | | SHALL HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION | | | FOR PERSONNEL. ALL OUTLETS IN THE KITCHEN, BATHROOM, | | | OUTDOORS, LAUNDRY, UTILITY, AND WET BAR SINKS SHALL BE | | | GFCI PROTECTED. NEC 210.8. | | | | | | 9) METAL FRAMING MEMBERS SHALL BE BONDED TO THE | | | EQUIPMENT GROUNDING CONDUCTOR FOR THE CIRCUIT THAT MAY | | | ENERGIZE THE FRAMING AND BE SIZED IN ACCORDANCE WITH | | | THE NEC TABLE 250.122. FOR THE PURPOSE OF THIS SECTION, | | | A GROUNDED METAL OUTLET BOX ATTACHED TO THE FRAMING | | | SHALL BE PERMITTED. FBC 2704 | | | | | | SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | | ARE REQUIRED FOR SECURITY, CCTV, STUCTURED CABLING, | | | NETWORK, AUDIO/VIDEO, GENERATOR, SWIMMING POOL, | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-10-21 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-10-21 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-10-21 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2014-10-09 10:21:39 | DATE: 10/21/2014 | | | PROJECT: BARCELONA RD RENNOVATION | | | PERMIT#: 14080856 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) REVISE THE RISER DIAGRAM TO INDICATE A LOGICAL | | | DESIGN UTILIZING FULL SIZE SERVICE ENTRANCE CONDUCTORS | | | FEEDING PANELS "A" AND "B" NEC 310.15.(B)(6) . | | | | | | 2) REVISE THE RISER DIAGRAM TO INCLUDE AN EQUIPMENT | | | GROUNDING CONDUCTOR IN THE FEEDER TO THE GARAGE PANEL. | | | NEC 250.122 | | | | | | 3) REVISE THE PANEL "A" SCHEDULE TO TO CORRECT PROBABLE | | | TYPO FOR KITCHEN CIRCUIT #23 INDICATING A 60AMP OCPD | | | WITH #12 WIRE. | | | | | | 4) CLARIFY THE TYPE, RATING, SIZE AND USE FOR THE | | | GUTTER INDICATED ABOVE PANELS "A" AND "B" ON THE RISER | | | DIAGRAM. WPB AMENDMENTS TO THE FBC 107.3.2 | | | | | | 5) VERIFY LUMINAIRES IN CLOTHES CLOSETS SHALL BE | | | INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THE NEC | | | 410.16(A) AND (B). | | | | | | 6) VERIFY ALL RECEPACLE OUTLETS INSTALLED THROUGHOUT | | | SHALL BE IN COMPLIANCE WITH NEC 210.52(A)(1) SHALL BE | | | INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY | | | ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 1.8 | | | M (6 FT) FROM A RECEPTACLE OUTLET. | | | | | | 7) INDICATE THE REQUIRED WORKING CLEARANCES FOR THE A/C | | | DISCONNECTS. SEE NEC 110.26 | | | SUFFICIENT ACCESS AND WORKING SPACE SHALL BE PROVIDED | | | AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT | | | READY AND SAFE OPERATION AND MAINTENANCE OF SUCH | | | EQUIPMENT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-09-17 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-17 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-17 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2014-09-17 17:04:07 | DATE: 9/17/2014 | | | PROJECT: BARCELONA RD RENNOVATION | | | PERMIT#: 14080856 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) ADDITIONAL RECEPTACLES ARE REQUIRED. ADD RECEPTACLES | | | SO THAT NO WALL SPACE IS MORE THAN 6 FEET FROM A | | | RECEPTACLE AND ALL WALL SPACES MORE THAN 2 FEET IN | | | WIDTH HAVE A RECEPTACLE. NEC 210.52(A)(1) | | | | | | 2) AT LEAST ONE RECEPTACLE SHALL BE INSTALLED AT EACH | | | ISLAND COUNTERTOP SPACE WITH ALONG DIMENSION OF 600 MM | | | (24 IN.) OR GREATER AND A SHORT DIMENSION OF 300 MM (12 | | | IN.) OR GREATER.NEC 210.52(C)(2) | | | | | | 3) KITCHEN COUNTER TOP RECEPTACLES SHALL BE SUPPLIED BY | | | NO FEWER THAN TWO SMALL APPLIANCE BRANCH CIRCUITS. NEC | | | 210.52 (B)(3) | | | | | | 4) ALL NEW GENERAL PURPOSE OUTLETS MUST BE AFCI | | | PROTECTED. NEC 210.12 NEW RECEPTACLES MUST BE TAMPER | | | RESISTANT. NEC 406.11 | | | | | | 5) FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET ACCESSIBLE WHILE STANDING AT | | | GRADE LEVEL AND LOCATED NOT MORE THAN 2.0 M (61.2 FT) | | | ABOVE GRADE SHALL BE INSTALLED AT THE FRONT AND BACK OF | | | THE DWELLING. NEC 210.52(E)(3) | | | | | | 6) PROVIDE A LIGHTING OUTLET AND SWITCH FOR ATTIC | | | ACCESS. 210.70(A)(3) | | | | | | 7) INDICATE THE LOCATION FOR THE ELECTRICAL PANELS. | | | | | | 8) INDICATE LOCATION OF A/C CONDENSING UNITS AND THE | | | ELECTRICAL CIRCUITS AND REQUIRED DISCONNECTS. | | | | | | 9) ONE 125VOLT, SINGLE-PHASE, 15 OR 20AMP GFI | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE | | | LOCATION FOR THE SERVICING OF HEATING, | | | AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT. THE | | | RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND | | | WITHIN 25FT OF THE HEATING, AIR-CONDITIONING, AND | | | REFRIGERATION EQUIPMENT. THE RECEPTACLE OUTLET SHALL | | | NOT BE CONNECTED TO THE LOAD SIDE OF THE EQUIPMENT | | | DISCONNECTING MEANS. NEC 210.63 SEE 210.8(A)(3), | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
N |
Date |
2014-10-27 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-10-27 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-10-27 11:46:47 | ALREADY APPROVED 8/13/14. JG. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-08-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-08-13 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-08-13 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2014-08-13 09:28:19 | PASSED BASED ON PREVIOUS APPROVAL. SPOKE TO OWNER WHO | | | INTENDS TO SUBMIT FOR A NEW/DIFFERENT WINDOW PRODUCT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-11-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-11-05 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-10-31 |
Time |
06:48 |
Sent To |
|
|
| Notes |
| 2014-11-01 06:44:35 | GAVE TO DHAYES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-10-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-10-27 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-10-07 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-17 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-17 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-13 |
Time |
18:29 |
Sent To |
|
|
| Notes |
| 2014-08-14 18:56:18 | 8/14 EXPEDITED REQUEST SUBMITTED | | | | | 2014-08-14 18:35:45 | R10 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2014-10-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-10-24 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-10-24 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2014-10-24 17:28:54 | NO FEES DUE. MU-14-021078. JG. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-09-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-09-12 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-09-12 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2014-09-12 14:04:20 | 1- BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT | | | FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY | | | OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY | | | IMPACT FEE ORDINANCE OF THE LAND DEVELOPMENT CODE. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-10-27 |
|
|
Cont ID |
|
| Sent By |
HMOSER |
Date |
2014-10-27 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-10-27 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2014-08-20 |
Time |
|
Rev Time |
0.25 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-08-20 15:37:36 | PLEASE PROVIDE ENERGY SHEETS FOR ALL NEW SPACES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-10-18 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-18 |
Time |
05:37 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-18 |
Time |
05:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-09-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-01 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-01 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2014-09-01 09:00:50 | 1) SUBMIT SANITARY & WATER RISER DIAGRAMS FOR ALL NEW | | | WORK TO BE DONE. WPB ADMIN. AMEND. TO 2010 FBC | | | SEC.107.2.1. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2014-09-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-09-12 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-09-12 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2014-09-12 14:05:51 | 1- ROOFING TILE FL7804-R7. | | | 2- ROOFING TILE ADHESIVE FL6332-R4. | | | 3- ROOFING UNDERLAYMENT FL11915-R3. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2014-10-27 |
|
|
Cont ID |
|
| Sent By |
fmitner |
Date |
2014-10-27 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-10-27 11:46:01 | ALREADY APPROVED 8/13/14. JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-08-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-08-13 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-08-13 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|