Plan Review Details - Permit 14080406
Plan Review Stops For Permit 14080406
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2015-01-22 Cont ID  
Sent By shill Date 2015-01-22 Time 16:07 Rev Time 0.00
Received By shill Date 2015-01-22 Time 16:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-01-09 Cont ID  
Sent By shill Date 2015-01-09 Time 18:01 Rev Time  
Received By shill Date 2015-01-09 Time 15:13 Sent To  
Notes
2015-01-09 16:50:46****CORRECTIONS****
 PLAN REVIEW IN PROGRESS
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FROM PREVIOUS (2ND REVIEW) LIST:
  
 1. THE PRODUCT APPROVAL SUBMITTED (FL 7621-R2) HAS NO
 EVIDENCE OF REVIEW BY TIMOTHYJ. MESSLER, PE, ENGINEER
 OF RECORD.
  
 3RD REVIEW, PLEASE PROVIDE A SHOP DRAWING REVIEW STAMP
 OR INCORPORATE INTO THE DRAWING. THE RESPONSE LETTER IS
 NOT TYPICALLY RETAINED AS A PART OF THE PERMIT
 DOCUMENTS.
  
 2. GENERAL NOTES COVER SHEET INDICATES A DESIGN
 PRESSURE OF -67 PSF WHICH EXCEEDS ANY MAXIMUM ALLOWABLE
 PRESSURE OF THE ROOFING PANEL. ADDITIONALLY, EXPOSURE B
 IS CLAIMED BUT THE EXISTANCE OF A BASEBALL PARK TO THE
 EAST OF THE PROPERTY RESULTS IN AN EXPOSURE C. SEE THE
 ROOFING PANEL INSTRUCTIONS FOR SITE SPECIFIC REQUIRED
 DESIGN WIND PRESSURES.
  
 ENGINEER'S RESPONSE REGARDING WIND DIRECTION IS
 ACKNOWLEDGED. ASCE7-10 DOES NOT ALLOW DESIGNING FOR THE
 UPWIND DIRECTION FOR COMPONENTS AND CLADDING, ONLY FOR
 MWFRS. I RESPECTFULLY REQUEST THAT THE ENGINEER
 RECONSIDERS THE EXPOSURE CLASSIFICATION AFTER REVIEWING
 ASCE7-10 SECTIONS ****. IF ENGINEER DISAGREES AFTER
 REVIEWING THESE SECTIONS, HE WILL BE REFERRED TO THE
 BUILDING OFFICIAL TO DISCUSS.
  
 3. EXISTING BUILDING DATA ON SHEET 3 INDICATES THE TYPE
 OF CONSTRUCTION AS IIB AND THAT THE PROPOSED
 IMPROVEMENT IS ALSO TYPE IIB. THE ROOF PANELS ARE NOT
 OF NON COMBUSTIBLE CONSTRUCTION AS REQUIRED FOR IIB.
 CONSIDER RECLASSIFYING THE STRUCTURE PER TABLE 503
 RESPONSE LETTER STATES THAT THIS HAS BEEN REVISED, BUT
 PLANS STILL DECLARE BUILDING AS IIB. PLEASE ADDRESS.
 NEW COMMENTS:
  
 4. ROOF PANEL INSTALLATION INSTRUCTIONS FROM THE
 MANUFACTURER, PROVIDED BY THE ENGINEER APPEARS TO
 RECOMMEND A SLOPE OF 1/2" PER FOOT (IT IS VERY
 DIFFICULT TO READ), BUT PLANS SHOW A 2" SLOPE FOR
 9'10". PLEASE ADDRESS.
  
 5. FASTENING INFORMATION FOR THE ROOF PANELS WAS
 PROVIDED WITH A COPY OF A DOCUMENT PREPARED BY
 ENGINEERING EXPRESS. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED,
 SEALED, DATED ORIGINALS. DELEGATED ENGINEERING IS TO BE
 REVIEWED BY ENGINEER OF RECORD, FAC61G15-23.
 ALTERNATIVELY, ENGINEER OF RECORD CAN SPECIFY
 FASTENING.
  
 6. IT IS NOT CLEAR HOW THE ROOF PRESSURE WAS
 DETERMINED. WHAT SQUARE FOOT AREA WAS USED FOR THE AREA
 TRIBUTARY TO A FASTENER? ROOF PRESSURE FOR A FLAT ROOF
 APPEAR LOW, EVEN FOR EXPOSURE B.
  
 IT IS SUGGESTED THAT THE REVISING THE WIND DESIGN
 CRITERIA TO RISK CATEGORY 1, 150MPH, EXPOSURE C WOULD
 RESULT IN DESIGN PRESSURE OF ZONE 3 FOR THE ROOF, 10 SQ
 FEET OF -61.32 PER TABLE **** ASCE7-10.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-11-26 Cont ID  
Sent By skennedy Date 2014-11-26 Time 15:23 Rev Time 0.00
Received By skennedy Date 2014-11-26 Time 15:23 Sent To  
Notes
2014-11-26 15:25:112ND REVIEW: FBC 2010
  
 THERE IS A SIMILAR EXISTING ALUMINUM STRUCTURE ATTACHED
 TO A BUILDING ON THIS PROPERTY TO THE N OF THE PROPOSED
 IMPROVEMENT. THERE DOES NOT APPEAR TO BE A PERMIT
 RECORD FOR THIS STRUCTURE. PLEASE PROVIDE EVIDENCE OF
 THIS PERMIT.
  
 THE PRODUCT APPROVAL SUBMITTED (FL 7621-R2) HAS NO
 EVIDENCE OF REVIEW BY TIMOTHYJ. MESSLER, PE, ENGINEER
 OF RECORD. ADDITIONALLY, THIS PRODUCT IS FOR PANELS OF
 4" OR 6" THICKNESS. THE MESSLER DRAWING SPECIFYS PANELS
 OF 3" THICKNESS. PLEASE CLARIFY.
  
 THE ROOF PANEL SPAN IS SHOWN AS 9'10" ON SHEET 2 AND
 12'0" ON SHEET 3. PLEASE CLARIFY.
  
 DETAIL A, SHEET 3 SHOWS AN ALUMINUM I BEAM AS EXISTING.
 THIS DOES NOT APPEAR TO BE ACCURATE. PLEASE VERIFY.
  
 GENERAL NOTES COVER SHEET INDICATES A DESIGN PRESSURE
 OF -67 PSF WHICH EXCEEDS ANY MAXIMUM ALLOWABLE PRESSURE
 OF THE ROOFING PANEL. ADDITIONALLY, EXPOSURE B IS
 CLAIMED BUT THE EXISTANCE OF A BASEBALL PARK TO THE
 EAST OF THE PROPERTY RESULTS IN AN EXPOSURE C. SEE THE
 ROOFING PANEL INSTRUCTIONS FOR SITE SPECIFIC REQUIRED
 DESIGN WIND PRESSURES.
  
 EXISTING BUILDING DATA ON SHEET 3 INDICATES THE TYPE OF
 CONSTRUCTION AS IIB AND THAT THE PROPOSED IMPROVEMENT
 IS ALSO TYPE IIB. THE ROOF PANELS ARE NOT OF NON
 COMBUSTIBLE CONSTRUCTION AS REQUIRED FOR IIB. CONSIDER
 RECLASSIFYING THE STRUCTURE PER TABLE 503
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-09-02 Cont ID  
Sent By shill Date 2014-09-02 Time 17:29 Rev Time 0.00
Received By shill Date 2014-09-02 Time 17:29 Sent To  
Notes
2014-09-02 17:43:58****CORRECTIONS****
 **SPOKE WITH CONTRACTOR, APPLICATION HAS INCORRECT
 ADDRESS. NEED NEW APPLICATION AND $100 CHANGE OF
 ADDRESS FEE**
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE ADDRESS FOR THE PERMIT APPLICATION IS NOT
 CONSISTENT WITH THE SURVEY. THIS PARCEL IS NORTH OF
 FRANCIS ST, PROPOSED IMPROVEMENT IS SHOWN AS SOUTH OF
 FRANCIS. IT APPEARS THAT THE AERIAL SHOWS AN AREA SHOWN
 ON THE SURVEY AS "COVERED CONCRETE" AS ATTACHED TO A
 BUILDING ON ANOTHER PARCEL. PLEASE ADDRESS.
  
 2. PROVIDE INFORMATION REGARDING THE EXISTING BUILDING
 (BUILDING SUMMARY): BUILDING TYPE FBC CHAPTER 6, HEIGHT
 AND AREA FBC CHAPTER 5, SPRINKLERED OR NOT SPRINKLERED,
 OCCUPANCY CLASSIFICATION FBC CHAPTER 3, SQUARE FOOT
 AREA OF EXISTING, SQUARE FOOT AREA OF PROPOSED
 ADDITION.
  
 3. PROVIDE THE FLORIDA STATE PRODUCT APPROVAL FOR THE
 ROOF PANELS, FAC9N-3, FBC 1609.
  
 NOT ENOUGH INFORMATION PROVIDED TO DETERMINE CODE
 COMPLIANCE.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2014-12-19 Cont ID  
Sent By pleduc Date 2014-12-19 Time   Rev Time 0.00
Received By pleduc Date 2014-12-19 Time 12:05 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-11-25 Cont ID  
Sent By pleduc Date 2014-11-25 Time   Rev Time 0.00
Received By pleduc Date 2014-11-25 Time 12:31 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2014-09-04 Cont ID  
Sent By pleduc Date 2014-09-04 Time   Rev Time 0.00
Received By pleduc Date 2014-09-04 Time 14:38 Sent To PC
Notes
2014-09-04 15:23:26THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE REFER TO BUILDING COMMENTS AS THEY MIRROR FIRE
 PREVENTION.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-01-22 Cont ID  
Sent By shill Date 2015-01-22 Time 16:07 Rev Time 0.00
Received By shill Date 2015-01-16 Time 17:48 Sent To  
Notes
2015-01-16 17:49:21RE-SUBMITTAL SENT TO SAMANTHA HILL FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-01-09 Cont ID  
Sent By shill Date 2015-01-09 Time 18:01 Rev Time 0.00
Received By shill Date 2014-12-17 Time 10:29 Sent To  
Notes
2014-12-18 10:45:41B12

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-11-26 Cont ID  
Sent By skennedy Date 2014-11-26 Time 16:29 Rev Time 0.00
Received By skennedy Date 2014-11-04 Time 10:39 Sent To  
Notes
2014-11-05 10:39:52TO ZONING
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-09-04 Cont ID  
Sent By pleduc Date 2014-09-04 Time   Rev Time 0.00
Received By pleduc Date 2014-08-11 Time 15:52 Sent To PC
Notes
2014-09-02 17:44:229/2 TO FIRE
  
2014-08-11 15:52:13ROUTED TO ZONING
  

Review Stop Z ZONING
Rev No 2 Status P Date 2014-12-29 Cont ID  
Sent By sgraham Date 2014-12-29 Time 16:09 Rev Time 0.00
Received By sgraham Date 2014-12-29 Time 16:09 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2014-08-12 Cont ID  
Sent By sgraham Date 2014-08-12 Time 11:47 Rev Time 0.00
Received By sgraham Date 2014-08-12 Time 11:47 Sent To B
Notes
2014-11-24 17:06:21SG REVIEWED AGAIN ON 11/5/14 PER INITIALS ON RE-SUB
 SHEET.