2014-08-19 10:35:08****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS,
 SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING
 CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR
 BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING
 CANNOT BE REDUCED BY MORE THAN 5%.
  
 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 50 5/8" IN
 HEIGHT:
  
 REVISE PLAN TO STATE WHAT TYPE OF WINDOW IS THERE NOW
 IN THE BEDROOMS - AWNING, CASEMENT, SINGLE HUNG?
  
 REVISE PLAN TO STATE WHAT THE EXISTING CLEAR OPENING
 DIMENSIONS ARE. CLEAR OPENING IS THE OPENING WHICH
 EXISTS WHEN THE WINDOW IS FULLY OPEN.
  
 REVISE PLAN TO STATE WHAT THE PROPOSED CLEAR OPENING
 DIMENSIONS ARE. THIS CAN BE OBTAINED FROM THE
 MANUFACTURER
  
 3. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB, FBC
 109.
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2014-08-07 Cont ID  
Sent By fmittner Date 2014-08-07 Time 14:05 Rev Time 0.00
Received By fmittner Date 2014-08-07 Time 13:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-08-19 Cont ID  
Sent By shill Date 2014-08-19 Time 10:35 Rev Time 0.00
Received By shill Date 2014-08-07 Time 14:49 Sent To  
Notes
2014-08-07 14:49:55SENT TO MISC # 1. JW