2014-09-10 10:32:29PLAN REVIEW COMMENTS
  
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 BUILDING
  
 1) FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. SUBMIT PRODUCT APPROVALS FOR THE SINGLE HUNG
 WINDOWS AND HAVE THE DESIGNER REVIEW AND APPROVE ALL OF
 THEM IN WRITING.
  
 2) THE WIND-LOAD PRESSURES FOR THE WINDOWS AND EXTERIOR
 DOORS ARE A LITTLE LOW. THE PRESSURES FOR A 10 SQFT
 OPENING IN 170MPH VULT, 132 VASD EXPOSURE C WITH A 15'
 MEAN ROOF HEIGHT IS +37.9 PSF, -41.1 PSF IN WALL ZONE 4
 AND +37.9 PSF, -50.7 PSF IN WALL ZONE 5. PLEASE REVIEW
 AND ADJUST.
  
 3) FBC - R 301.2.1.2 SUBMIT TWO COPIES OF AN
 INSTALLATION SCHEDULE AND KEY PLAN FOR THE STORM
 PANELS. SPECIFY THE TYPE OF ANCHOR, ANCHOR SPACING,
 EDGE DISTANCE, PANEL LENGTH, SEPARATION DISTANCE FROM
 PANEL TO GLASS AND THE APPLICABLE SECTION NUMBER FROM
 THE INSTALLATION DRAWINGS.
  
 4) THE VALUATION STATED ON THE APPLICATION OF
 $60,000.00 IS LOW AND HAS BEEN ADJUSTED TO $199,602.00
 BASED ON THE LATEST ICC VALUATION DATA.
  
 IN ORDER TO REDUCE PLAN REVIEW TIMES, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-09-10 Cont ID  
Sent By rmcdouga Date 2014-09-10 Time 08:58 Rev Time 0.00
Received By rmcdouga Date 2014-09-10 Time 07:16 Sent To  
Notes
2014-09-10 08:59:33PLANS HAVE BEEN RED-LINED WITH REQUIREMENTS.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-10-09 Cont ID  
Sent By rmcdouga Date 2014-10-09 Time 08:52 Rev Time 0.00
Received By rmcdouga Date 2014-10-08 Time 17:02 Sent To  
Notes
2014-10-08 17:03:53TO RM DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-10-06 Cont ID  
Sent By rmcdouga Date 2014-10-06 Time 16:48 Rev Time 0.00
Received By rmcdouga Date 2014-09-24 Time 17:53 Sent To  
Notes
2014-09-24 17:53:24TO RM DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-09-10 Cont ID  
Sent By rmcdouga Date 2014-09-10 Time 13:53 Rev Time 0.00
Received By rmcdouga Date 2014-08-07 Time 14:47 Sent To  
Notes
2014-08-07 14:47:53SENT TO R13

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2014-10-09 Cont ID  
Sent By rmcdouga Date 2014-10-09 Time 08:50 Rev Time 0.00
Received By rmcdouga Date 2014-10-09 Time 08:38 Sent To  
Notes
2014-10-09 08:52:15MU-2014-20547, PAID $180.65

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2014-10-06 Cont ID  
Sent By rmcdouga Date 2014-10-06 Time 15:30 Rev Time 0.00
Received By rmcdouga Date 2014-10-06 Time 14:17 Sent To  
Notes
2014-10-06 15:30:11SUBMIT A COPY OF THE PAID RECEIPT FOR THE IMPACT FEES.
 ( MU 2014 - 20547 )

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-09-10 Cont ID  
Sent By rmcdouga Date 2014-09-10 Time 06:52 Rev Time 0.00
Received By rmcdouga Date 2014-09-10 Time 06:51 Sent To  
Notes
2014-09-10 06:52:56IMPACT FEES
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND
 TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED
 WITH A COPY OF RECEIPT AS APPLICABLE.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2014-08-26 Time   Rev Time 0.50
Received By   Date   Time   Sent To  
Notes
2014-08-26 13:35:57AS NOTED !

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-09-10 Cont ID  
Sent By rmcdouga Date 2014-09-10 Time 07:20 Rev Time 0.00
Received By rmcdouga Date 2014-09-10 Time 07:16 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2014-08-07 Cont ID  
Sent By sgraham Date 2014-08-07 Time 15:17 Rev Time 0.00
Received By sgraham Date 2014-08-07 Time 15:17 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved