| 2014-08-07 12:06:10 | BUILDING PLAN REVIEW |
| | PERMIT: 14080263/ RE-ISSUE 03020253 |
| | ADD: 1686 39TH ST |
| | CONT: T. H. MOTTLEY |
| | TEL: (561)502-1986 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURSDAY AUGUST 07/2014 |
| | ACTION: DENIED |
| | |
| | 1A) IDENTIFY THE SLOPE OF THE ROOF &, THE MEAN ROOF |
| | HEIGHT, THE ROOFING PRODUCT APPROVAL SUBMITTED |
| | 02-1205.05 DOES NOT PROVIDE THE TYPE OF FASTENERS IF |
| | SCREWS OR RING SHANK NAILS INDENTFY, PAGE 4 OR PAGE 5 |
| | IF A ADHESIVE SYSTEM OR MORTAR IDENTIFY SYSTEM AND |
| | MINIMUM RESISTANCE REQUIED. |
| | |
| | 1B) IF THE ROOF TILE IS USING A ADHESIVE OR MORTAR SET |
| | SYSTEM THE TYPE OF UNDERLAYMENT WILL NEED TO BE KNOWN |
| | IF IT IS A PEEL AND STICK SYSTEM. |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 107.2.1.2 FOR ROOF |
| | ASSEMBLIES REQUIRED BY THE CODE, THE CONSTRUCTION |
| | DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND DELINEATE THE |
| | TYPE OF ROOFING SYSTEM, MATERIALS, FASTENING |
| | REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE |
| | RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT |
| | EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE |
| | WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |