| Plan Review Stops For Permit 14080234 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-12-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-12-16 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-12-16 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2014-12-16 09:50:16 | CONTRIBUTING STRUCTURE - EXEMPT FROM FBC 2010 ENERGY | | | CONSERVATION , SEE SECTION 101.4.2 | | | LETTER FROM F.MITTNER PUT IN FILE | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-09-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-13 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-09-12 |
Time |
07:26 |
Sent To |
Z |
|
| Notes |
| 2014-09-13 10:54:39 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. OUR RECORDS DO NOT SHOW A PERMIT FOR THE FIRST FLOOR | | | APARTMENT, REAR STRUCTURE. | | | | | | PLANS ARE NOT CLEAR AS TO SCOPE AND DO NOT MAKE | | | REFERENCE TO A CHANGE OF OCCUPANCY. AS THE TUB WAS | | | SHOWN AS "EXISTING", MY INITIAL REVIEW WAS DONE ON | | | WINDOWS ONLY. PLANS DO NOT SHOW THAT THE ENTIRE FIRST | | | FLOOR IS A GARAGE TO BE CONVERTED TO AN APARTMENT. | | | | | | ANYTHING WHICH WAS BUILT WITHOUT A PERMIT IS NOT | | | "EXISTING." THE ISSUE OF THE REAR BUILDING HAS ALREADY | | | BEEN BROUGHT UP IN THE PAST BY ANOTHER PLANS EXAMINER | | | ON ANOTHER PERMIT. | | | | | | PROVIDE AN "EXISTING" PLAN FOR BOTH FLOORS. "EXISTING" | | | IS TO SHOW CONDITIONS WHICH WERE LEGALLY PERMITTED. | | | | | | PROVIDE A "PROPOSED" PLAN WHICH SHOWS ALL PROPOSED | | | CONSTRUCTION, INCLUDING ITEMS WHICH MAY BE ALREADY | | | INSTALLED BUT WERE CONSTRUCTED WITHOUT A PERMIT. UNLESS | | | PERMITTED, IT IS NOT "GRANDFATHERED" REGARDLESS OF WHEN | | | THE CONSTRUCTION WAS DONE. | | | | | | PLANS ARE TO INCLUDE METHOD OF COMPLIANCE SELECTED, SEE | | | FBC 2010 EXISTING BUILDING 101.5. THIS APPEARS TO BE | | | BOTH AN ALTERATION AS WELL AS A CHANGE OF OCCUPANCY. | | | PLANS SHOULD INCLUDE THIS INFORMATION FOR AN ACCURATE | | | PLAN REVIEW. | | | | | | IT APPEARS THAT THERE IS ONE EXISTING UNIT (2ND FLOOR), | | | AND A NEW APARTMENT IS PROPOSED, BUT NO TENANT | | | SEPARATION WAS SHOWN. ENERGY CALCS WERE NOT PROVIDED. | | | INSULATION, WALL DETAILS, ETC. WERE NOT PROVIDED. | | | | | | A COMPLETE CHECKLIST CANNOT BE PROVIDED AT THIS TIME | | | DUE TO THE AMBIGUITY OF THE PLAN PROVIDED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-08-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-08-22 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-08-22 |
Time |
18:16 |
Sent To |
E |
|
| Notes |
| 2014-08-22 18:17:43 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. REVISE FLOOR PLAN TO PROVIDE THE FOLLOWING | | | INFORMATION FOR THE 38" HIGH BEDROOM WINDOWS; FBC R310, | | | FBC EB 604.1. THE CLEAR OPENING CANNOT BE REDUCED BY | | | MORE THAN 5%: | | | | | | REVISE PLAN TO STATE WHAT TYPE OF WINDOW IS THERE NOW | | | IN THE BEDROOMS - AWNING, CASEMENT, SINGLE HUNG? | | | | | | REVISE PLAN TO STATE WHAT THE EXISTING CLEAR OPENING | | | DIMENSIONS ARE. CLEAR OPENING IS THE OPENING WHICH | | | EXISTS WHEN THE WINDOW IS FULLY OPEN. | | | | | | REVISE PLAN TO STATE WHAT THE PROPOSED CLEAR OPENING | | | DIMENSIONS ARE. THIS CAN BE OBTAINED FROM THE | | | MANUFACTURER | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2015-01-14 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-14 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-14 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2015-01-14 11:23:45 | DATE: 01/14/2015 | | | PROJECT: 36TH ST REAR BLDG | | | PERMIT#: 14080234 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC, WPB AMENDMENTS TO THE FBC, | | | CHAPTER 1, ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 4TH ELECTRICAL PLAN REVIEW | | | ACTION: APPROVED WITH EXCEPTION | | | | | | PROVIDE AN AS BUILT FOR ELECTRICAL INSPECTOR ON SITE | | | PER EXISTING CONDITIONS. | | | | | | 1) FBC-WPB AMENDMENTS 107.3.5 | | | INDICATE THE TRUE SCOPE AND EXTENT OF ELECTRICAL | | | IMPROVEMENTS. THE APPLICATION STATES "INTERIOR | | | IMPROVEMENTS AND WINDOW REPLACEMENT" THE PLAN PROVIDES | | | ELECTRICAL DETAILS AND NOTES. CLARIFICATION IS | | | REQUIRED. INDICATE WHAT IS EXISTING TO REMAIN. WHAT IS | | | REMOVED AND OR RELOCATED AND WHAT IS COMPLETELY NEW OR | | | SIMPLY REPLACED. | | | | | | 2) PROVIDE A RISER DIAGRAM, LOAD CALCULATION AND A | | | PANEL SCHEDULE. NEC 215.5, 220, 408.4 | | | | | | 3) IDENTIFY THE LOCATION AND SIZE OF THE ELECTRICAL | | | SERVICE, MAIN DISCONNECT, PANEL, CONDUITS AND FEEDER | | | CONDUCTORS. | | | | | | 4) IDENTIFY THE CIRCUITRY FOR THE OUTLETS AND LIGHTS | | | THROUGHOUT TO COINCIDE WITH THE PANEL CIRCUIT | | | DIRECTORY. FBC, WPB AMENDMENTS 107.3.2 | | | | | | 5) VERIFY RECEPTACLES SHALL BE INSTALLED SUCH THAT NO | | | POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY | | | WALL SPACE IS MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE | | | OUTLET OR 24" FOR KITCHEN COUNTERTOPS. 210.52(A)(1), | | | 210.52(C)(1), | | | | | | 6) ALL HABITABLE LIVING AREA REQUIRES A SWITCHED LIGHT | | | OR SWITCH CONTROLLED OUTLET. NEC 210.70. THE LIVING | | | ROOM HAS NO SWITCH CONTROLLED LIGHT OUTLET. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2014-12-16 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-16 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-16 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2014-12-16 10:58:36 | 12/16/2014 | | | PROJECT: 438 36TH ST, REAR | | | PERMIT#: 14080234 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 3RD ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE A RISER DIAGRAM, AND A PANEL SCHEDULE. EVERY | | | CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY | | | IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC | | | PURPOSE OR USE. NEC 408.4, NEC 215.5, FBC-WPB | | | AMENDMENTS 107.3.5 | | | | | | 2) IDENTIFY THE LOCATIONS OF THE ELECTRICAL SERVICE AND | | | IDENTIFY THE CIRCUITRY OF THE OUTLETS AND LIGHTS | | | THROUGHOUT TO COINCIDE WITH THE PANEL CIRCUIT | | | DIRECTORY. | | | | | | 3) REVISE LOAD CALCULATION IN COMPLIANCE WITH THE NEC. | | | ALL SQUARE FOOTAGE HAS NOT BEEN ACCOUNTED FOR IN THE | | | CALCULATION PROVIDED. LOADS FOR NEW CIRCUITS OR | | | EXTENDED CIRCUITS IN PREVIOUSLY WIRED DWELLING UNITS | | | SHALL BE CALCULATED IN ACCORDANCE WITH EITHER 220.12 OR | | | 220.14, AS APPLICABLE. NEC 220.16(2) | | | | | | 4) VERIFY RECEPTACLES SHALL BE INSTALLED SUCH THAT NO | | | POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY | | | WALL SPACE IS MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE | | | OUTLET OR 24" FOR KTCHEN COUNTERTOPS. 210.52 (A)(1), | | | 210.52(C)(1), | | | | | | 5) ALL HABITABLE LIVING AREA REQUIRES A SWITCHED LIGHT | | | OR SWITCH CONTROLLED OUTLET. NEC 210.70 | | | | | | 6) OCCUPIABLE BALCONIES AND PORCHES OVER 20 SQ FT MUST | | | HAVE A GFI RECEPTACLE OUTLET. NEC 210.52(E)(3) | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | | | 2014-10-31 16:07:58 | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-22 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-22 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2014-09-22 14:42:25 | DATE: 9/22/2014 | | | PROJECT: 36TH ST REAR BLDG | | | PERMIT#: 14080234 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL | | | 314 AND 315. | | | | | | 2) PROVIDE A RISER DIAGRAM, AND A PANEL SCHEDULE. | | | | | | 3) IDENTIFY THE LOCATIONS OF THE ELECTRICAL SERVICE AND | | | THE ELECTRICAL PANEL. IDENTIFY THE CIRCUITRY OF THE | | | OUTLETS AND LIGHTS THROUGHOUT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-09-02 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-02 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-02 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2014-09-02 12:19:21 | DATE: 9/2/2014 | | | PROJECT: INTERIOR IMPROVEMENTS | | | PERMIT#: 14080234 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL | | | 314.3 AND 314.3.1 INDICATE ALL LOCATIONS AND TYPES OF | | | SMOKE/CO DETECTORS REQUIRED BY THE FBC 314 & 315. | | | | | | 2) INDICATE THE TRUE SCOPE AND EXTENT OF ELECTRICAL | | | IMPROVEMENTS. THE APPLICATION STATES "INTERIOR | | | IMPROVEMENTS AND WINDOW REPLACEMENT" THE PLAN PROVIDES | | | AN ELECTRICAL LOAD CALCULATION AND ELECTRICAL NOTES | | | "RECEPTACLE SHALL BE TAMPER RESISTANT", AND "ALL SMOKE | | | DETECTORS SHALL BE INTERCONNECTED" HOWEVER THE LOCATION | | | AND TYPES OF SMOKE/CO DETECTORS IS NOT INDICATED ON THE | | | PLANS. CLARIFICATION ID REQUIRED. INDICATE WHAT IS | | | EXISTING TO REMAIN. WHAT ID REMOVED AND OR RELOCATED | | | AND WHAT IS COMPLETELY NEW OR SIMPLY REPLACED OLD WITH | | | NEW. | | | | | | 2) INDIICATE THE LOCATION OF THE ELECTRICAL PANEL. | | | | | | 3) AN ELECTRICAL PERMIT REQUIRED. | | | | | | 4) | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT | | | /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM | | | ITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | | | 2014-08-06 18:32:21 | SENT TO ZONING |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-10-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-10-30 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-10-30 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-09-16 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-09-16 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-09-16 |
Time |
16:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-08-19 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-08-19 |
Time |
15:57 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-01-14 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-14 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-02 |
Time |
15:34 |
Sent To |
P |
|
| Notes |
| 2015-01-03 15:36:39 | TO TKL DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-12-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-27 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-10-27 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2014-10-28 11:10:34 | SENT TO R-02. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-22 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-22 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-04 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2014-09-13 10:55:27 | 9/13 TO ZONING | | | | | 2014-09-04 17:52:48 | SENT TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-02 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-02 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-22 |
Time |
18:18 |
Sent To |
|
|
| Notes |
| 2014-08-22 18:18:16 | 8/22 TO ELEC BOX | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2015-09-03 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-03 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-03 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2015-01-03 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-01-03 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-01-03 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2015-01-03 15:35:32 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED. | | | CONTACT 561-233-5025 FOR MORE INFORMATION. THIS MAY BE | | | DONE AFTER ALL PLAN REVIEWS ARE PASSED BUT BEFORE | | | PERMIT IS ISSUED. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2014-12-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-12-16 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-12-16 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2014-12-16 09:02:36 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED. | | | CONTACT 561-233-5025 FOR MORE INFORMATION. THIS MAY BE | | | DONE AFTER ALL PLAN REVIEWS ARE PASSED BUT BEFORE | | | PERMIT IS ISSUED. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-09-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-13 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-09-13 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2014-09-13 11:05:30 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PLANS ARE TO CLEARLY DEPICT PROPOSED WORK. | | | | | | IF THE WORK INCLUDES CONVERSION OF | | | UNIHABITABLE/STORAGE/GARAGE SPACE TO LIVING SPACE, | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | | | | | IF THE WORK INCLUDES CONVERSION INTO AN ADDITIONAL | | | APARTMENT/DWELLING UNIT, IMPACT FEE ASSESSMENT BY PALM | | | BEACH COUNTY IS REQUIRED. | | | | | | PLANS SHOULD INCLUDE ALL INFORMATION THE PALM BEACH | | | COUNTY WOULD REQUIRE FOR A CORRECT IMPACT FEE | | | ASSESSMENT. CONTACT 561-233-5025 FOR MORE INFORMATION. | | | THIS MAY BE DONE AFTER ALL PLAN REVIEWS ARE PASSED BUT | | | BEFORE PERMIT IS ISSUED. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2014-12-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-27 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-12-27 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2014-12-27 12:18:00 | NO MECHANICAL IS SHOWN. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-01-13 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-14 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-13 |
Time |
05:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-12-18 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-12-18 |
Time |
05:05 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-12-18 |
Time |
04:52 |
Sent To |
|
|
| Notes |
| 2014-12-18 05:03:33 | 1) SUBMIT A SANITARY AND WATER RISER FOR THE PLUMBING | | | WORK TO BE DONE.WPB AMEND.TO 2010 FBC SEC.107.3.5.3. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2014-10-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-10-30 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-10-30 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2014-10-30 13:44:31 | ONLY ONE UNIT IN BACK STRUCTURE PER GREEN CARD. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-09-16 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-09-16 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-09-16 |
Time |
16:56 |
Sent To |
E |
|
| Notes |
| 2014-09-16 17:01:50 | NEED DOCUMENTATION THAT TWO UNITS EXIST IN DETACHED | | | STRUCTURE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-08-19 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-08-19 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2014-08-07 09:32:25 | 8/7/14 ZONING SENT TO FM. SG |
|
|