Plan Review Details - Permit 14080234
Plan Review Stops For Permit 14080234
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-12-18 Cont ID  
Sent By shill Date 2014-12-16 Time 09:49 Rev Time 0.00
Received By shill Date 2014-12-16 Time 09:03 Sent To  
Notes
2014-12-16 09:50:16CONTRIBUTING STRUCTURE - EXEMPT FROM FBC 2010 ENERGY
 CONSERVATION , SEE SECTION 101.4.2
 LETTER FROM F.MITTNER PUT IN FILE
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-09-13 Cont ID  
Sent By shill Date 2014-09-13 Time 10:37 Rev Time 0.00
Received By shill Date 2014-09-12 Time 07:26 Sent To Z
Notes
2014-09-13 10:54:39****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. OUR RECORDS DO NOT SHOW A PERMIT FOR THE FIRST FLOOR
 APARTMENT, REAR STRUCTURE.
  
 PLANS ARE NOT CLEAR AS TO SCOPE AND DO NOT MAKE
 REFERENCE TO A CHANGE OF OCCUPANCY. AS THE TUB WAS
 SHOWN AS "EXISTING", MY INITIAL REVIEW WAS DONE ON
 WINDOWS ONLY. PLANS DO NOT SHOW THAT THE ENTIRE FIRST
 FLOOR IS A GARAGE TO BE CONVERTED TO AN APARTMENT.
  
 ANYTHING WHICH WAS BUILT WITHOUT A PERMIT IS NOT
 "EXISTING." THE ISSUE OF THE REAR BUILDING HAS ALREADY
 BEEN BROUGHT UP IN THE PAST BY ANOTHER PLANS EXAMINER
 ON ANOTHER PERMIT.
  
 PROVIDE AN "EXISTING" PLAN FOR BOTH FLOORS. "EXISTING"
 IS TO SHOW CONDITIONS WHICH WERE LEGALLY PERMITTED.
  
 PROVIDE A "PROPOSED" PLAN WHICH SHOWS ALL PROPOSED
 CONSTRUCTION, INCLUDING ITEMS WHICH MAY BE ALREADY
 INSTALLED BUT WERE CONSTRUCTED WITHOUT A PERMIT. UNLESS
 PERMITTED, IT IS NOT "GRANDFATHERED" REGARDLESS OF WHEN
 THE CONSTRUCTION WAS DONE.
  
 PLANS ARE TO INCLUDE METHOD OF COMPLIANCE SELECTED, SEE
 FBC 2010 EXISTING BUILDING 101.5. THIS APPEARS TO BE
 BOTH AN ALTERATION AS WELL AS A CHANGE OF OCCUPANCY.
 PLANS SHOULD INCLUDE THIS INFORMATION FOR AN ACCURATE
 PLAN REVIEW.
  
 IT APPEARS THAT THERE IS ONE EXISTING UNIT (2ND FLOOR),
 AND A NEW APARTMENT IS PROPOSED, BUT NO TENANT
 SEPARATION WAS SHOWN. ENERGY CALCS WERE NOT PROVIDED.
 INSULATION, WALL DETAILS, ETC. WERE NOT PROVIDED.
  
 A COMPLETE CHECKLIST CANNOT BE PROVIDED AT THIS TIME
 DUE TO THE AMBIGUITY OF THE PLAN PROVIDED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-08-22 Cont ID  
Sent By shill Date 2014-08-22 Time 18:16 Rev Time 0.00
Received By shill Date 2014-08-22 Time 18:16 Sent To E
Notes
2014-08-22 18:17:43****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. REVISE FLOOR PLAN TO PROVIDE THE FOLLOWING
 INFORMATION FOR THE 38" HIGH BEDROOM WINDOWS; FBC R310,
 FBC EB 604.1. THE CLEAR OPENING CANNOT BE REDUCED BY
 MORE THAN 5%:
  
 REVISE PLAN TO STATE WHAT TYPE OF WINDOW IS THERE NOW
 IN THE BEDROOMS - AWNING, CASEMENT, SINGLE HUNG?
  
 REVISE PLAN TO STATE WHAT THE EXISTING CLEAR OPENING
 DIMENSIONS ARE. CLEAR OPENING IS THE OPENING WHICH
 EXISTS WHEN THE WINDOW IS FULLY OPEN.
  
 REVISE PLAN TO STATE WHAT THE PROPOSED CLEAR OPENING
 DIMENSIONS ARE. THIS CAN BE OBTAINED FROM THE
 MANUFACTURER
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2015-01-14 Cont ID  
Sent By dhayes Date 2015-01-14 Time 11:23 Rev Time 0.00
Received By dhayes Date 2015-01-14 Time 11:22 Sent To  
Notes
2015-01-14 11:23:45DATE: 01/14/2015
 PROJECT: 36TH ST REAR BLDG
 PERMIT#: 14080234
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC, WPB AMENDMENTS TO THE FBC,
 CHAPTER 1, ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 4TH ELECTRICAL PLAN REVIEW
 ACTION: APPROVED WITH EXCEPTION
  
 PROVIDE AN AS BUILT FOR ELECTRICAL INSPECTOR ON SITE
 PER EXISTING CONDITIONS.
  
 1) FBC-WPB AMENDMENTS 107.3.5
 INDICATE THE TRUE SCOPE AND EXTENT OF ELECTRICAL
 IMPROVEMENTS. THE APPLICATION STATES "INTERIOR
 IMPROVEMENTS AND WINDOW REPLACEMENT" THE PLAN PROVIDES
 ELECTRICAL DETAILS AND NOTES. CLARIFICATION IS
 REQUIRED. INDICATE WHAT IS EXISTING TO REMAIN. WHAT IS
 REMOVED AND OR RELOCATED AND WHAT IS COMPLETELY NEW OR
 SIMPLY REPLACED.
  
 2) PROVIDE A RISER DIAGRAM, LOAD CALCULATION AND A
 PANEL SCHEDULE. NEC 215.5, 220, 408.4
  
 3) IDENTIFY THE LOCATION AND SIZE OF THE ELECTRICAL
 SERVICE, MAIN DISCONNECT, PANEL, CONDUITS AND FEEDER
 CONDUCTORS.
  
 4) IDENTIFY THE CIRCUITRY FOR THE OUTLETS AND LIGHTS
 THROUGHOUT TO COINCIDE WITH THE PANEL CIRCUIT
 DIRECTORY. FBC, WPB AMENDMENTS 107.3.2
  
 5) VERIFY RECEPTACLES SHALL BE INSTALLED SUCH THAT NO
 POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY
 WALL SPACE IS MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE
 OUTLET OR 24" FOR KITCHEN COUNTERTOPS. 210.52(A)(1),
 210.52(C)(1),
  
 6) ALL HABITABLE LIVING AREA REQUIRES A SWITCHED LIGHT
 OR SWITCH CONTROLLED OUTLET. NEC 210.70. THE LIVING
 ROOM HAS NO SWITCH CONTROLLED LIGHT OUTLET.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2014-12-16 Cont ID  
Sent By dhayes Date 2014-12-16 Time 10:56 Rev Time 0.00
Received By dhayes Date 2014-12-16 Time 10:56 Sent To  
Notes
2014-12-16 10:58:3612/16/2014
 PROJECT: 438 36TH ST, REAR
 PERMIT#: 14080234
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 3RD ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) PROVIDE A RISER DIAGRAM, AND A PANEL SCHEDULE. EVERY
 CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY
 IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC
 PURPOSE OR USE. NEC 408.4, NEC 215.5, FBC-WPB
 AMENDMENTS 107.3.5
  
 2) IDENTIFY THE LOCATIONS OF THE ELECTRICAL SERVICE AND
 IDENTIFY THE CIRCUITRY OF THE OUTLETS AND LIGHTS
 THROUGHOUT TO COINCIDE WITH THE PANEL CIRCUIT
 DIRECTORY.
  
 3) REVISE LOAD CALCULATION IN COMPLIANCE WITH THE NEC.
 ALL SQUARE FOOTAGE HAS NOT BEEN ACCOUNTED FOR IN THE
 CALCULATION PROVIDED. LOADS FOR NEW CIRCUITS OR
 EXTENDED CIRCUITS IN PREVIOUSLY WIRED DWELLING UNITS
 SHALL BE CALCULATED IN ACCORDANCE WITH EITHER 220.12 OR
 220.14, AS APPLICABLE. NEC 220.16(2)
  
 4) VERIFY RECEPTACLES SHALL BE INSTALLED SUCH THAT NO
 POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY
 WALL SPACE IS MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE
 OUTLET OR 24" FOR KTCHEN COUNTERTOPS. 210.52 (A)(1),
 210.52(C)(1),
  
 5) ALL HABITABLE LIVING AREA REQUIRES A SWITCHED LIGHT
 OR SWITCH CONTROLLED OUTLET. NEC 210.70
  
 6) OCCUPIABLE BALCONIES AND PORCHES OVER 20 SQ FT MUST
 HAVE A GFI RECEPTACLE OUTLET. NEC 210.52(E)(3)
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  
2014-10-31 16:07:58 
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2014-09-22 Cont ID  
Sent By shill Date 2014-09-22 Time 07:31 Rev Time 0.00
Received By dhayes Date 2014-09-22 Time 14:40 Sent To  
Notes
2014-09-22 14:42:25DATE: 9/22/2014
 PROJECT: 36TH ST REAR BLDG
 PERMIT#: 14080234
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC
 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
  
 2ND ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL
 314 AND 315.
  
 2) PROVIDE A RISER DIAGRAM, AND A PANEL SCHEDULE.
  
 3) IDENTIFY THE LOCATIONS OF THE ELECTRICAL SERVICE AND
 THE ELECTRICAL PANEL. IDENTIFY THE CIRCUITRY OF THE
 OUTLETS AND LIGHTS THROUGHOUT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO
 SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED
 SHEETS FOR COMPARATIVE REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-09-02 Cont ID  
Sent By dhayes Date 2014-09-02 Time 11:40 Rev Time 0.00
Received By dhayes Date 2014-09-02 Time 11:40 Sent To  
Notes
2014-09-02 12:19:21DATE: 9/2/2014
 PROJECT: INTERIOR IMPROVEMENTS
 PERMIT#: 14080234
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC
 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
  
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL
 314.3 AND 314.3.1 INDICATE ALL LOCATIONS AND TYPES OF
 SMOKE/CO DETECTORS REQUIRED BY THE FBC 314 & 315.
  
 2) INDICATE THE TRUE SCOPE AND EXTENT OF ELECTRICAL
 IMPROVEMENTS. THE APPLICATION STATES "INTERIOR
 IMPROVEMENTS AND WINDOW REPLACEMENT" THE PLAN PROVIDES
 AN ELECTRICAL LOAD CALCULATION AND ELECTRICAL NOTES
 "RECEPTACLE SHALL BE TAMPER RESISTANT", AND "ALL SMOKE
 DETECTORS SHALL BE INTERCONNECTED" HOWEVER THE LOCATION
 AND TYPES OF SMOKE/CO DETECTORS IS NOT INDICATED ON THE
 PLANS. CLARIFICATION ID REQUIRED. INDICATE WHAT IS
 EXISTING TO REMAIN. WHAT ID REMOVED AND OR RELOCATED
 AND WHAT IS COMPLETELY NEW OR SIMPLY REPLACED OLD WITH
 NEW.
  
 2) INDIICATE THE LOCATION OF THE ELECTRICAL PANEL.
  
 3) AN ELECTRICAL PERMIT REQUIRED.
  
 4)
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT
 /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM
 ITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO
 SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED
 SHEETS FOR COMPARATIVE REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  
2014-08-06 18:32:21SENT TO ZONING

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2014-10-30 Cont ID  
Sent By fmittner Date 2014-10-30 Time 13:44 Rev Time 0.00
Received By fmittner Date 2014-10-30 Time 13:44 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2014-09-16 Cont ID  
Sent By fmittner Date 2014-09-16 Time 16:56 Rev Time 0.00
Received By fmittner Date 2014-09-16 Time 16:55 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2014-08-19 Cont ID  
Sent By fmittner Date 2014-08-19 Time 15:57 Rev Time 0.00
Received By fmittner Date 2014-08-19 Time 15:57 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-01-14 Cont ID  
Sent By dhayes Date 2015-01-14 Time 11:24 Rev Time 0.00
Received By dhayes Date 2015-01-02 Time 15:34 Sent To P
Notes
2015-01-03 15:36:39TO TKL DESK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-12-27 Cont ID  
Sent By skennedy Date 2014-12-27 Time 12:18 Rev Time 0.00
Received By skennedy Date 2014-10-27 Time 11:09 Sent To  
Notes
2014-10-28 11:10:34SENT TO R-02. JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-09-22 Cont ID  
Sent By dhayes Date 2014-09-22 Time 14:49 Rev Time 0.00
Received By dhayes Date 2014-09-04 Time 17:52 Sent To  
Notes
2014-09-13 10:55:279/13 TO ZONING
  
2014-09-04 17:52:48SENT TO S HILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-09-02 Cont ID  
Sent By dhayes Date 2014-09-02 Time 12:19 Rev Time 0.00
Received By dhayes Date 2014-08-22 Time 18:18 Sent To  
Notes
2014-08-22 18:18:168/22 TO ELEC BOX
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2015-09-03 Cont ID  
Sent By skennedy Date 2015-09-03 Time 14:32 Rev Time 0.00
Received By skennedy Date 2015-09-03 Time 10:39 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2015-01-03 Cont ID  
Sent By skennedy Date 2015-01-03 Time 15:34 Rev Time 0.00
Received By skennedy Date 2015-01-03 Time 15:34 Sent To  
Notes
2015-01-03 15:35:32****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED.
 CONTACT 561-233-5025 FOR MORE INFORMATION. THIS MAY BE
 DONE AFTER ALL PLAN REVIEWS ARE PASSED BUT BEFORE
 PERMIT IS ISSUED.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2014-12-16 Cont ID  
Sent By shill Date 2014-12-16 Time 09:01 Rev Time 0.00
Received By shill Date 2014-12-16 Time 09:01 Sent To  
Notes
2014-12-16 09:02:36****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED.
 CONTACT 561-233-5025 FOR MORE INFORMATION. THIS MAY BE
 DONE AFTER ALL PLAN REVIEWS ARE PASSED BUT BEFORE
 PERMIT IS ISSUED.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-09-13 Cont ID  
Sent By shill Date 2014-09-13 Time 11:02 Rev Time 0.00
Received By shill Date 2014-09-13 Time 11:02 Sent To  
Notes
2014-09-13 11:05:30****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. PLANS ARE TO CLEARLY DEPICT PROPOSED WORK.
  
 IF THE WORK INCLUDES CONVERSION OF
 UNIHABITABLE/STORAGE/GARAGE SPACE TO LIVING SPACE,
 IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED.
  
 IF THE WORK INCLUDES CONVERSION INTO AN ADDITIONAL
 APARTMENT/DWELLING UNIT, IMPACT FEE ASSESSMENT BY PALM
 BEACH COUNTY IS REQUIRED.
  
 PLANS SHOULD INCLUDE ALL INFORMATION THE PALM BEACH
 COUNTY WOULD REQUIRE FOR A CORRECT IMPACT FEE
 ASSESSMENT. CONTACT 561-233-5025 FOR MORE INFORMATION.
 THIS MAY BE DONE AFTER ALL PLAN REVIEWS ARE PASSED BUT
 BEFORE PERMIT IS ISSUED.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2014-12-27 Cont ID  
Sent By skennedy Date 2014-12-27 Time 12:17 Rev Time 0.00
Received By skennedy Date 2014-12-27 Time 12:17 Sent To  
Notes
2014-12-27 12:18:00NO MECHANICAL IS SHOWN.

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-01-13 Cont ID  
Sent By dhayes Date 2015-01-14 Time 11:24 Rev Time 0.00
Received By tklarge Date 2015-01-13 Time 05:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-12-18 Cont ID  
Sent By tklarge Date 2014-12-18 Time 05:05 Rev Time 0.00
Received By tklarge Date 2014-12-18 Time 04:52 Sent To  
Notes
2014-12-18 05:03:331) SUBMIT A SANITARY AND WATER RISER FOR THE PLUMBING
 WORK TO BE DONE.WPB AMEND.TO 2010 FBC SEC.107.3.5.3.

Review Stop Z ZONING
Rev No 3 Status P Date 2014-10-30 Cont ID  
Sent By fmittner Date 2014-10-30 Time 13:44 Rev Time 0.00
Received By fmittner Date 2014-10-30 Time 13:44 Sent To  
Notes
2014-10-30 13:44:31ONLY ONE UNIT IN BACK STRUCTURE PER GREEN CARD.

Review Stop Z ZONING
Rev No 2 Status F Date 2014-09-16 Cont ID  
Sent By fmittner Date 2014-09-16 Time 16:56 Rev Time 0.00
Received By fmittner Date 2014-09-16 Time 16:56 Sent To E
Notes
2014-09-16 17:01:50NEED DOCUMENTATION THAT TWO UNITS EXIST IN DETACHED
 STRUCTURE

Review Stop Z ZONING
Rev No 1 Status P Date 2014-08-19 Cont ID  
Sent By fmittner Date 2014-08-19 Time 15:56 Rev Time 0.00
Received By fmittner Date 2014-08-19 Time 15:56 Sent To  
Notes
2014-08-07 09:32:258/7/14 ZONING SENT TO FM. SG