| 2014-08-21 09:29:03 | 2010 FLORIDA GAS CODE & FLORIDA PLUMBING CODE |
| | |
| | 1)THE PERMIT APPLICATION WORK DESCRIPTION STATES |
| | "INSTALL GAS LINES" BUT THE ATTACHED PROPOSAL INCLUDES |
| | THE INSTALLATION OF SANITARY PLUMBING & WATER LINES AND |
| | THE INSTALLATION OF PLUMBJIMNG FIXTURES. CLARIFY. |
| | 2) SUBMIT SANITARY AND WATER RISERS FOR THE PLUMBING |
| | WORK TO BE DONE. |
| | 3) SUBMIT A SLAB REPAIR DETAIL FOR ANY SLAB SECTION |
| | THAT IS TO BE CUT AND REMOVED. |
| | 4) SUBMIT MANUFACTURER SHEETS FOR ALL GAS APPLIANCES. |
| | APPLIANCES SHALL BE LISTED IN ACCORDANCE W/SEC.301.3 OF |
| | THE 2010 FGC. |
| | 5) SUBMIT COPIES OF THE APPLICABLE GAS SIZING TABLE |
| | FROM THE GAS CODE FOR THIS PROJECT. |
| | 6) SHOW THE LENGTH OF ALL CUT SECTIONS OF THE GAS PIPE |
| | INCLUDING THE BRANCH LINES TO THE APPLIANCES AND SHOW |
| | THE TOTAL DISTANCE FROM THE POINT OF DELIVERY TO THE |
| | MOST REMOTE OUTLET PERR THE 2010 FGC SEC.402.4.1. |
| | 7) THE PIPING TO THE WATER HEATER & THE 6 BURNER STOVE |
| | ARE UNDERSIZED. ALSO THE 1 1/4 " BRANCH LINE TO THE |
| | APPLIANCES IS UNDERSIZED. |
| | 8) THE LONGEST RUN IS OVER 40 FT.FROM THE POINT OF |
| | DELIVERY TO THE MOST REMOTE OUTLET. REVISE THE TOTAL |
| | DISTANCE AND THE SIZING. |
| | 9) REVISE THE COST OF THE PROJECT ON THE APPLICATION. |
| | THE VALUE SHOWN ON THE PROPOSAL IS $4350.00 AND THE |
| | APPLICATION STATES $2500.00 A NOTICE OF COMMENCEMENT |
| | WILL BE REQUIRED. |
| | |
| | |
| | |
| | TIM LARGE |