Plan Review Details - Permit 14080183
Plan Review Stops For Permit 14080183
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-11-05 Cont ID  
Sent By shill Date 2014-11-05 Time 17:16 Rev Time 0.00
Received By shill Date 2014-11-05 Time 17:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-10-12 Cont ID  
Sent By shill Date 2014-10-12 Time 10:38 Rev Time 0.00
Received By shill Date 2014-10-12 Time 10:38 Sent To  
Notes
2014-10-12 10:38:48****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FROM PREVIOUS LIST:
  
 1. PROVIDE TEST REPORT (OR OTHER DOCUMENTATION TO SHOW
 COMPLIANCE) FOR AWNING FABRIC, FBC 3105.3.1.
  
 NEW COMMENTS:
  
 AS THE FABRIC IS TO BE REMOVED, PROVIDE THE FOLLOWING:
  
 2. PROVIDE AWNING FABRIC REMOVAL INSTRUCTIONS TO SHOW
 COMPLIANCE WITH FBC3105.4.2.1, QUICK RELEASE. THE
 INSTRUCTIONS SHOULD CONSIST OF A SERIES OF PHOTOGRAPHS.
 THIS IS TO BE APPROVED BY THE BUILDING OFFICIAL.
  
 3. PER BUILDING OFFICIAL, WE ARE TO PUT ON THE PERMIT
 FILE A LETTER, OR CONTRACTORS FORM, SIGNED BY THE OWNER
 (NOT THE TENANT) TO ACKNOWLEDGE THEIR RESPONSIBILITY TO
 HAVE THE AWNING COVER REMOVED PRIOR TO ANY WIND EVENT
 WITH PROJECTED WIND SPEEDS OF 75 MPH OR GREATER. THE
 LETTER/FORM MUST BE SIGNED BY THE OWNER BUT IT NEED NOT
 BE NOTARIZED.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-09-04 Cont ID  
Sent By shill Date 2014-09-04 Time 18:32 Rev Time 0.00
Received By shill Date 2014-09-04 Time 18:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-11-05 Cont ID  
Sent By shill Date 2014-11-05 Time 17:17 Rev Time 0.00
Received By shill Date 2014-10-28 Time 14:32 Sent To  
Notes
2014-10-28 14:32:28INCOMING SENT TO S. HILL'S DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-10-12 Cont ID  
Sent By shill Date 2014-10-12 Time 10:40 Rev Time 0.00
Received By shill Date 2014-09-24 Time 18:21 Sent To  
Notes
2014-09-24 18:21:27TO ZONING
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-09-04 Cont ID  
Sent By shill Date 2014-09-04 Time 18:32 Rev Time 0.00
Received By shill Date 2014-08-05 Time 16:06 Sent To  
Notes
2014-08-05 16:07:04ROUTED TO ZONING
2014-08-05 16:06:28ROUTED TO ZONING
  

Review Stop Z ZONING
Rev No 3 Status P Date 2014-10-14 Cont ID  
Sent By eschneid Date 2014-10-14 Time 14:54 Rev Time 0.25
Received By eschneid Date 2014-10-14 Time 14:54 Sent To  
Notes
2014-10-14 14:54:41MANAGEMENT STAMP PROVIDED. NO RESUB FEE.

Review Stop Z ZONING
Rev No 2 Status F Date 2014-10-09 Cont ID  
Sent By eschneid Date 2014-10-09 Time 21:39 Rev Time 0.25
Received By eschneid Date 2014-10-09 Time 21:39 Sent To B
Notes
2014-10-09 21:58:081) THE MANAGEMENT STAMP WAS NOT PROVIDED ON THE
 DRAWINGS.
  
 PLANS OK
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2014-09-02 Cont ID  
Sent By eschneid Date 2014-09-02 Time 10:31 Rev Time 0.25
Received By eschneid Date 2014-09-02 Time 10:31 Sent To B
Notes
2014-09-02 10:38:48FAILED
  
 1) THE MANAGEMENT STAMP WAS NOT PROVIDED ON THE
 DRAWINGS.
  
 2) NO BUILDING ELEVATION PLAN WAS PROVIDED TO SHOW
 WHERE THE AWNINGS ARE LOCATED. THE FOUR PROPOSED AWNING
 TYPES SHALL BE SPECIFICALLY TIED TO THEIR LOCATION ON
 THE ELEVATION PLAN.
  
 3) THE ELEVATION PLAN SHALL VERIFY THAT THE MINIMUM
 CLEARANCE OF EACH AWNING IS EIGHT (8) FEET ABOVE GRADE.
  
 4) THE AWNINGS SHALL BE CENTERED ABOVE THE OPENINGS
 THAT THEY COVER.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2014-08-06 14:45:068/6/14 ZONING SENT TO AV. SG