Plan Review Details - Permit 14080175
| Plan Review Stops For Permit 14080175 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-24 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-24 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-09-03 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-03 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-03 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-08-11 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-08-11 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-08-11 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-09-06 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-09-04 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2014-09-05 11:35:55 | SENT TO H MOSER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-03 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-03 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-05 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-09-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-09-06 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-09-06 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-08-15 |
|
|
Cont ID |
|
| Sent By |
jdariton |
Date |
2014-08-15 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
jdariton |
Date |
2014-08-15 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2014-08-15 10:10:59 | NOTES; | | | 1.PROVIDE OUTSIDE AIR CALCULATIONS BASED ON THE TOTAL | | | OCCUPANT LOAD AND AS REQUIRED BY 2010 FMC, TABLE 403.3 | | | OR ASHRAE 62.1-2004.USE EQUATION 4-1 AS REQUIRED BY SEC | | | 403.3.1.1. | | | 2.SHOW ON PLANS LOCATION OF ALL FIRE DAMPERS IF ANY. | | | 3.CLARIFY ON PLANS IF YOU HAVE TRANSFER DUCTS( JUMPER) | | | OR TRANSFER R/A GRILLS AS SHOWN ON PLANS. | | | 4.INDICATE ON PLANS THE SIZES OF ALL RETURN AIR | | | TRANSFER DUCTS AND SUPPLY AIR DUCTS. | | | 5.IF DUCTS PENETRATE THROUGH FIRE/SMOKE RATED | | | PARTITIONS THEY SHALL BE PROTECTED WITH APPROVED | | | FIRE/SMOKE DAMPERS,INSTALLED IN ACCORDANCE WITH THEIR | | | LISTING AS REQUIRED BY FBC-MECHANICAL SEC.607.1.1. | | | 6.SINCE THE BUILDING HAS EXISTING SMOKE EVAC.SYSTEM, | | | THEN PROVIDE SUFFICIENT INFORMATION ON PLANS AND | | | INDICATE IF THE SYSTEM HAS BEEN AFFECTED BY THIS | | | ALTERATION. ALSO INCLUDE OPERATIONAL AND ACCEPTANCE | | | TESTING PROCEDURES AS REQUIRED BY FMC,SEC.513.1 AND | | | 513.2. | | | 7.INDICATE ON PLANS COMPLIANCE TO FMC, SEC.602.2.1 FOR | | | MATERIALS WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR | | | SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND | | | A SMOKE DEVELOPED INDEX NOT MORE THAN 50 WHEN TESTED IN | | | ACCORDANCE WITH ASTM E 84 OR UL 723. | | | REVIEWED BY JOHN ARITON.FOR QUESTION PLEASE CALL HAROLD | | | MOSER AT 561-805-6732. |
|
|
|