| Plan Review Stops For Permit 14080077 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-01-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-17 |
Time |
03:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-17 |
Time |
02:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-07 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-07 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2014-08-07 13:49:55 | BUILDING PLAN REVIEW | | | PERMIT: 14080077 | | | ADD: 104 CLEMATIS ST | | | CONT: ATLANTIC GENERAL CONTRACTING | | | TEL: (561)434-4171 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. AUGUST 07/2014 | | | ACTION: DENIED | | | | | | 1) 1210.1 FLOORS AND WALL BASE FINISH MATERIALS. | | | IN OTHER THAN DWELLING UNITS, TOILET, BATHING AND | | | SHOWER ROOM FLOOR FINISH MATERIALS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE. THE INTERSECTIONS OF SUCH | | | FLOORS WITH WALLS SHALL HAVE A SMOOTH, HARD, | | | NONABSORBENT VERTICAL BASE THAT EXTENDS UPWARD ONTO THE | | | WALLS AT LEAST 4 INCHES (102 MM). | | | | | | 2) 1210.2 WALLS AND PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF URINALS | | | AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | | NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET (1219 MM) | | | ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS, | | | THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE | | | THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-01-17 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-17 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-17 |
Time |
15:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-08-04 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-04 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-08-11 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-08-11 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-08-11 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2014-08-11 16:06:54 | PERMIT # 14080077 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ADD AN EMERGENCY LIGHT WITH BATTERY BACK-UP IN THIS | | | SPACE. | | | | | | SUE ELLEN CALDERON | | | FIRE INSPECTOR & INVESTIGATOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-01-17 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-17 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-15 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-01-16 10:58:18 | SENT TO T. K. LARGES' DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-08-15 |
|
|
Cont ID |
|
| Sent By |
jdariton |
Date |
2014-08-15 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
jdariton |
Date |
2014-08-04 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2014-08-15 |
|
|
Cont ID |
|
| Sent By |
jdariton |
Date |
2014-08-15 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
jdariton |
Date |
2014-08-15 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2014-08-15 13:05:30 | NO MECHANICAL WORK SHOWN ON PLANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-01-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-17 |
Time |
03:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-17 |
Time |
02:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2015-01-08 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-08 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-08 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2015-01-08 10:51:50 | 1) SHOW THE REQUIRED KNEE AND TOE CLEARANCES UNDER THE | | | LAVATORY. COMPLY WITH THE 2010 FBC, ACCESSIBILITY | | | SECS.306 & 606. | | | 2) THE HEIGHT OF THE GRAB BARS SHALL BE MEASURED FROM | | | THE FINISH FLOOR TO THE TOP OF THE GRIPPING SURFACE, | | | NOT TO THE CENTERLINE OF THE GRAB BAR AS SHOWN. FL. | | | ACCESSIBILITY CODE SEC. 609.4. | | | 3) SUBMIT A WATER RISER DIAGRAM FOR REVIEW PER THE WPB | | | AMEND TO 2010 FBC SEC. 107.3.5.1.3. | | | 4) A CLEANOUT IS REQUIRED IN THE BASE OF THE WASTE | | | STACK PER THE 2010 FPC SEC.708.3.4. | | | 5) INDICATE IF THE DOOR TO THE RESROOM IS EQUIPPED WITH | | | A CLOSER AND LATCH. IF SO THEN A MIN. OF 12 INCHES OF | | | CLEARANCE SHALL BE PROVIDED PARALLEL TO THE DOORWAY | | | BEYOND THE LATCH SIDE PER THE FAC TABLE 404.2.4.1.SHOW | | | THE DIMENSION ON THE PLAN. | | | 6) COMPLY WITH THE BUILDING PLAN REVIEW COMMENTS FOR | | | THE WALLS. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-07 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-07 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2014-08-07 13:46:41 | PLUMBING PLAN REVIEW | | | PERMIT: 14080077 | | | ADD: 104 CLEMATIS ST | | | CONT: ATLANTIC GENERAL CONTRACTING | | | TEL: (561)434-4171 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. AUGUST 07/2014 | | | ACTION: DENIED | | | | | | 1) 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.3 PLUMBING | | | 1. MINIMUM PLUMBING FACILITIES | | | 2. FIXTURE REQUIREMENTS | | | 3. WATER SUPPLY PIPING | | | 4. SANITARY DRAINAGE | | | 5. WATER HEATERS | | | 6. VENTS | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|