| Plan Review Stops For Permit 14080028 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-12-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-24 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-24 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2014-12-24 07:42:26 | APPROVED WITH EXCEPTION | | | SUBMIT AN ADDITIONAL SET OF TRUSS DRAWINGS FOR APPROVAL | | | PRIOR TO ROOF FRAMING INSPECTION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-11-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-14 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-13 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2014-11-14 18:19:11 | PLAN REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | BUILDING | | | | | | 1) SUBMIT TWO SETS OF ENERGY CALCULATIONS THAT | | | ADEQUATELY REPRESENT THE STRUCTURE AND ITS COMPONENTS. | | | SEE COMMENTS #1 & #6 FROM 1ST REVIEW. FBC ENERGY | | | CONSERVATION SECT. 103.2.2 | | | | | | 2) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. SPECIFICALLY. | | | A) "STICKY BACK" ROOF TILE UNDERLAYMENT AS SPECIFIED ON | | | THE PLANS. | | | B) THE 6' X 8' OVERHEAD GARAGE DOOR. | | | C) THE PRODUCT APPROVAL FOR THE 3M, AH-160 FOAM ROOF | | | TILE ADHESIVE THAT HAD BEEN SUPERSEDED WAS REPLACED | | | WITH PRODUCT APPROVALS FOR 3M, RTA-1 (NOA 12-0228.18). | | | THE INSTALLATION NOTES REQUIRE THIS PRODUCT TO BE USED | | | WITH APPROVED ROOF TILES THAT LIST IT AS A METHOD OF | | | ATTACHMENT WITH A SPECIFIED MINIMUM ATTACHMENT | | | RESISTANCE. THE PRODUCT APPROVAL FOR THE ROOF TILE THAT | | | WAS SUBMITTED DOES NOT LIST THIS PRODUCT. FBC-R 301.1 | | | | | | 3) ONE SET OF THE TRUSS DRAWINGS IS MISSING FROM THE | | | SUBMITTAL. FBC107.1 GENERAL. SUBMITTAL DOCUMENTS | | | CONSISTING OF CONSTRUCTION DOCUMENTS, STATEMENT OF | | | SPECIAL INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA | | | SHALL BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. | | | | | | IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-09-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-09 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-28 |
Time |
18:58 |
Sent To |
|
|
| Notes |
| 2014-09-09 14:32:24 | PLAN REVIEW COMMENTS | | | | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | BUILDING | | | | | | 1) THE ENERGY COMPLIANCE FORM THAT WAS SUBMITTED FOR | | | THIS SINGLE FAMILY DWELLING IS WORST CASE AND DOES NOT | | | MATCH THE ORIENTATION OF THE STRUCTURE. THE HVAC LOAD | | | CALULATIONS THAT WERE SUBMITTED SPECIFY THAT THE FRONT | | | DOOR FACES SOUTHWEST. BASED ON THE SURVEY THAT WAS | | | SUBMITTED, THE FRONT DOOR FACES NORTHEAST. FBC ENERGY | | | CONSERVATION 403.6.1 | | | | | | 2) IDENTIFY THE ELEVATION THAT WILL BE USED FOR THIS | | | DWELLING AND CROSS OUT THE OTHERS. FBC 107.2.1 | | | | | | 3) FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | PROVIDE PRODUCT APPROVALS FOR THE ROOF TILE | | | UNDERLAYMENT AND THE 6 FOOT WIDE OVERHEAD GARAGE DOOR. | | | THE SLIDING GLASS DOOR NOA NO. 11- 1018.14 AND THE ROOF | | | TILE ADHESIVE NOA NO. 12-0228.18 HAVE BEEN SUPERSEDED. | | | THE FIXED WINDOW NOA NO. 13-0502.03 ONLY HAD 9 COPIES | | | OF THE FIRST PAGE. THE INSTALLATION DRAWINGS ARE | | | MISSING. | | | | | | 4) SPECIFY THE REQUIRED EMBEDMENT DEPTH OF THE 3/4" | | | DIA. ANCHOR BOLTS FOR THE COLUMN BASE IN DETAIL 1 ON | | | S-1. | | | | | | 5) PROVIDE AN ATTIC ACCESS TO UPPER ROOF FROM THE | | | SECOND FLOOR WITH A LIGHTING AND A RECEPTACLE OUTLET. | | | FBCR 807.1 | | | | | | 6) THE ENERGY CALCULATIONS LIST INSULATED DOORS FOR THE | | | DOORS WITH GLASS INSERTS. THE SIMULATED PERFORMANCE | | | METHOD SECTION 405.5.1 REQUIRES ALL GLAZING IN DOORS TO | | | BE INCLUDED IN THE TOTAL WINDOW AREA. 405.5.3 DOORS | | | WITH GLAZING. FOR DOORS THAT ARE OPAQUE OR WHERE THE | | | GLASS IS LESS THAN ONE-THIRD OF THE AREA OF THE DOOR, | | | THE TOTAL DOOR AREA SHALL BE INCLUDED IN THE DOOR | | | CALCULATION. FOR UNLABELED SLIDING GLASS DOORS OR WHEN | | | GLASS AREAS IN DOORS IS GREATER THAN OR EQUAL TO | | | ONE-THIRD OF THE AREA OF THE DOOR, THE GLAZING PORTION | | | SHALL BE INCLUDED IN THE GLAZING CALCULATION AND THE | | | OPAQUE PORTION OF THE DOOR SHALL BE INCLUDED IN THE | | | DOOR CALCULATION. WHEN GLASS AREA IN DOORS IS GREATER | | | THAN OR EQUAL TO ONE-THIRD OF THE AREA OF THE DOOR, THE | | | DOOR SHALL BE INCLUDED IN THE GLAZING CALCULATION AS A | | | TOTAL FENESTRATION USING THE TESTED U-FACTOR AND SOLAR | | | HEAT GAIN COEFFICIENT. | | | | | | 7) FBC 109.3 THE VALUATION ON THE APPLICATION OF | | | $295,522.00 IS LOW AND HAS BEEN ADJUSTED TO $432,598.00 | | | BASED ON THE LATEST ICC VALUATION DATA. | | | | | | IN ORDER TO REDUCE PLAN REVIEW TIMES, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-09-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-03 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-03 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2014-11-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-14 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-14 |
Time |
17:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2014-08-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-29 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-29 |
Time |
06:17 |
Sent To |
|
|
| Notes |
| 2014-08-29 16:02:25 | 2010 FBC | | | | | | GAS REVIEW DENIED | | | | | | 1) SPECIFY THE LENGTH AND SIZE OF EACH SECTION OF PIPE | | | ON THE GAS ISOMETRIC DRAWING. CITY AMENDMENTS 107.2.1 & | | | 2010 FBC FUEL GAS | | | | | | 2) SPECIFY THE 2010 FBC FUEL GAS AS THE APPLICABLE CODE | | | IN THE NOTES, RATHER THAN THE LATEST GAS CODE. CITY | | | AMENDMENTS 107.2.1 & FBCR CHAPTER 43. | | | | | | 3) THE TOTAL DEVELOPED LENGTH FROM THE METER TO THE | | | MOST REMOTE OUTLET IS INCONSISTENT. IT IS 84 L.F. ONE | | | PLACE AND 92 L.F. IN ANOTHER. CITY AMENDMENTS 107.2.1 & | | | 2010 FBCR APPENDIX A - USE OF CAPACITY SECTION A.3.1(4) | | | | | | 4) THE TOTAL BTUH LOAD IS SPECIFIED AS 265,000 BTUH, | | | HOWEVER THE TOTAL OF THE INDIVIDUAL APPLIANCE BTUH | | | LOADS ARE DIFFERENT. PLEASE CORRECT. | | | | | | 5) IF THE VOLUME OF GAS FOR THE APPLIANCE | | | (MANUFACTURER'S INPUT RATING) IS NOT KNOWN AT THE TIME | | | OF SUBMITTAL FOR PERMIT, THE RATING FROM TABLE 402.2 OF | | | THE 2010 FBC FUEL GAS SHALL BE USED. THE BTUH FOR A | | | CLOTHES DRYER IS 35,000 AND THE PLAN HAS 22,000. PLEASE | | | CORRECT. | | | | | | 6) THE PLANS SPECIFY 2-1/2" SHUT OFF VALVES AT THE | | | APPLIANCES WHERE THE PIPE SIZE IS SPECIFIED AS 1". | | | PLEASE CORRECT. | | | | | | 7) THE PLANS HAVE HAVE 160,000 BTUH FOR THE WATER | | | HEATER. THIS APPEARS TO BE HIGH FOR A TANK TYPE WATER | | | HEATER. PLEASE VERIFY. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2015-02-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-25 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-24 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-01-21 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-01-20 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2015-01-20 11:59:59 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-12-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-08 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-08 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2014-12-08 18:20:22 | PRODUCT APPROVAL SUBMITTAL PUT WITH DENIED PLANS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-11-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-14 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-10-30 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-09 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-31 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2014-08-04 09:58:08 | SENT TO R20.JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
5 |
Status |
P |
Date |
2015-02-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-25 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-25 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2015-02-25 08:27:24 | MU2014-16190 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2015-01-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-01-21 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-01-21 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2015-01-21 10:16:57 | SUBMIT A COPY OF THE PAID RECEIPT FOR THE PBC IMPACT | | | FEES. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2014-12-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-24 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-24 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2014-12-24 07:46:38 | (REPEAT COMMENT) A COPY OF THE PAID IMPACT FEE RECEIPT | | | IS REQUIRED TO BE SUBMITTED. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2014-11-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-14 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-13 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2014-11-14 17:24:56 | A COPY OF THE PAID IMPACT FEE RECEIPT IS REQUIRED TO BE | | | SUBMITTED. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-08-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-28 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-28 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2014-08-28 18:15:38 | IN ADDITION TO THE STAMPED PLANS, A COPY OF THE PAID | | | IMPACT FEE RECEIPT IS REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2015-02-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-25 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-25 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2015-01-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-01-21 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-01-21 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2015-01-21 08:30:46 | PLAN REVIEW COMMENTS | | | | | | | | | 4TH REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | MECHANICAL | | | | | | 1) (REPEAT COMMENT) THE LOAD CALCULATION AND ENERGY | | | FORM IS FOR TWO (2) SYSTEMS AND THE PLANS SPECIFY THREE | | | (3) SYSTEMS. PLEASE CORRECT. FBC 107.2.1 & FBC ENERGY | | | CONSERVATION 403.6.1.1 AND FBC 107.1.2 | | | | | | 2) THE MECHANICAL PLANS SPECIFY THREE (3) A/C UNITS. | | | TWO (2) 27,400 BTU/HR UNITS WITH 13.5 SEER AND ONE (1) | | | 17,800 BTU/HR UNIT WITH 14.5 SEER ARE SPECIFIED. THE | | | ENERGY FORM 405-10 LISTS TWO (2) UNITS. ONE (1) 27,400 | | | BTU/HR WITH 13.5 SEER AND ONE (1) 34,000 BTU/HR WITH | | | 13.5 SEER ARE LISTED. THE LOAD CALCULATIONS LIST THE | | | SAME TWO (2) UNITS AS THE WORST CASE ENERGY FORM | | | 405-10. PROVIDE THE LOAD CALCULATIONS FOR THE NORTEAST | | | ORIENTATION OF THE THE BUILDING AS SHOWN ON THE SURVEY | | | AND THE MANUFACTURER AND MODEL NUMBER OF THE OUTDOOR | | | AND INDOOR UNITS WITH THE SENSIBLE AND TOTAL COOLING | | | CAPACITIES AT THE DESIGN CONDITIONS AS REQUIRED BY FBC | | | ENERGY CONSERVATION SECTION 403.6 HEATING AND COOLING | | | EQUIPMENT (MANDATORY). | | | 403.6.1 EQUIPMENT SIZING. | | | HEATING AND COOLING EQUIPMENT SHALL BE SIZED IN | | | ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT | | | LOADS CALCULATED IN ACCORDANCE WITH MANUAL J OR OTHER | | | APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES, | | | BASED ON BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION | | | OF THE BUILDING. THE MANUFACTURER AND MODEL NUMBER OF | | | THE OUTDOOR AND INDOOR UNITS (IF SPLIT SYSTEM) SHALL BE | | | SUBMITTED ALONG WITH THE SENSIBLE AND TOTAL COOLING | | | CAPACITIES AT THE DESIGN CONDITIONS DESCRIBED IN | | | SECTION 302.1. THIS CODE DOES NOT ALLOW DESIGNER SAFETY | | | FACTORS, PROVISIONS FOR FUTURE EXPANSION OR OTHER | | | FACTORS WHICH AFFECT EQUIPMENT SIZING. SYSTEM SIZING | | | CALCULATIONS SHALL NOT INCLUDE LOADS CREATED BY LOCAL | | | INTERMITTENT MECHANICAL VENTILATION SUCH AS STANDARD | | | KITCHEN AND BATHROOM EXHAUST SYSTEMS. | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2014-12-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-23 |
Time |
19:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-23 |
Time |
19:08 |
Sent To |
|
|
| Notes |
| 2014-12-23 19:08:04 | PLAN REVIEW COMMENTS | | | | | | | | | 3RD REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | MECHANICAL | | | | | | 1) ( 2ND REPEAT COMMENT ) FBC 107.2.1 - INFORMATION ON | | | CONSTRUCTION DOCUMENTS. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. ( REPEAT COMMENT ) THERE IS NO SIGNATURE ON THE | | | MECHANICAL PLANS AT ALL, ELECTRONIC, DIGITAL OR OTHER | | | AS STATED IN YOUR LETTER. SEE FLORIDA STATUTES CHAPTER | | | 668 REGUARDING THE USE OF ELECTRONIC COMMERCE, | | | ELECTRONIC SIGNATURES AND DIGITAL SIGNATURES. | | | | | | 2) THE SURVEY THAT WAS SUBMITTED IS INCORRECT. ON SHEET | | | 1 OF THE SURVEY THE FRONT DOOR FACES NORTHEAST AND ON | | | SHEET 2 IT FACES EAST. SUBMIT A CORRECTED SURVEY. FBC | | | 107.2.1 | | | | | | 3) THE LOAD CALCULATION IS FOR TWO (2) SYSTEMS AND THE | | | PLANS SPECIFY THREE (3) SYSTEMS. PLEASE CORRECT. FBC | | | 107.2.1 & FBC ENERGY CONSERVATION 403.6.1.1 | | | | | | 4) THE WHOLE BUILDING LOAD FOR AN EAST ORIENTATION IS | | | 4.74 TONS AND FOR NORTHEAST IT IS 4.63 TONS. THE TOTAL | | | FOR THE EQUIPMENT ON THE MECHANICAL PLAN IS 6.05 TONS. | | | PER FBC ENERGY CONSERVATION 403.6.1.1 THE EQUIPMENT | | | SHOULD TOTAL 5 TONS. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2014-11-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-14 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-13 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2014-11-14 17:34:11 | PLAN REVIEW COMMENTS | | | | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | MECHANICAL | | | | | | 1) PROVIDE EQUIPMENT SIZING CALCULATIONS BASED ON THE | | | ACTUAL BUILDING ORIENTATION FOR THIS LOT, AS REQUIRED | | | BY SECTION 403.6 OF THE 2010 FBC - ENERGY CONSERVATION. | | | THE CALCULATIONS THAT WERE SUBMITTED AND THE EQUIPMENT | | | LISTED ON THE A/C PLAN ARE FOR WORST CASE. (REPEAT | | | COMMENT) | | | | | | 2) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. (REPEAT COMMENT) | | | | | | IN ORDER TO REDUCE PLAN REVIEW TIMES, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-20 |
Time |
|
Rev Time |
0.75 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-09-15 08:25:31 | PLAN REVIEW COMMENTS | | | | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | MECHANICAL | | | | | | 1) PROVIDE EQUIPMENT SIZING CALCULATIONS BASED ON THE | | | ACTUAL BUILDING ORIENTATION FOR THIS LOT, AS REQUIRED | | | BY SECTION 403.6 OF THE 2010 FBC - ENERGY CONSERVATION. | | | THE CALCULATIONS THAT WERE SUBMITTED AND THE EQUIPMENT | | | LISTED ON THE A/C PLAN ARE FOR WORST CASE. | | | | | | 2) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | IN ORDER TO REDUCE PLAN REVIEW TIMES, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | | 2014-08-20 15:02:32 | LOADED AND REVIEWED BY RBERGSMA |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-08-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-28 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-28 |
Time |
18:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-01-22 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-01-22 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-01-22 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2015-01-22 13:39:51 | 1/22/15 - SENT TO RM. DK | | 2015-01-22 13:34:11 | 1/22/15 - REVISED SURVEY MODIFYING TRUE NORTH | | | ORIENTATION OF THE SUBJECT PROPERTY WAS SUBMITTED FOR | | | REVIEW. ZONING APPROVED. DK |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-11-03 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-11-03 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-11-03 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-08-06 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-08-06 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-08-06 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2014-08-06 16:33:35 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 8/6/14 | | | | | | ITEMS TO BE REVISED/SUBMITTED: | | | | | | 1. A SEPARATE LANDSCAPE PERMIT IN CONFORMANCE WITH | | | ARTICLE XIV SHALL BE SUBMITTED. (NOTE: ZLDR SEC. | | | 94-442(B)(2)A. - FOR SINGLE-FAMILY DWELLING UNITS, AT | | | LEAST ONE SHADE, FLOWERING, OR FRUIT TREE SHALL BE | | | PLANTED FOR EACH 1,200 SQUARE FEET OF OPEN SPACE OR | | | PORTION THEREOF. FOR SINGLE-FAMILY DWELLING UNITS, AT | | | LEAST ONE SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE | | | FEET OF OPEN SPACE OR PORTION THEREOF. PLEASE ADJUST | | | CALCULATIONS TABLE.) | | | | | | OTHER COMMENTS: | | | | | | 2. SEPARATE PERMIT WILL BE REQUIRED FOR THE DRIVEWAY. | | | | | | 3. NOTE ADDED TO PLAN THAT PRIVACY WALL NOT UNDER ROOF | | | CAN NOT EXCEED 6' IN HEIGHT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|