| Plan Review Stops For Permit 14071212 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-03-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-18 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-18 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-12-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-23 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-23 |
Time |
12:36 |
Sent To |
P |
|
| Notes |
| 2014-12-23 15:15:03 | APPROVED WITH EXCEPTION | | | SUBMIT AN ADDITIONAL SET OF TRUSS DRAWINGS FOR APPROVAL | | | PRIOR TO ROOF FRAMING INSPECTION. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-11-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-13 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-12 |
Time |
07:06 |
Sent To |
P |
|
| Notes |
| 2014-11-13 17:13:53 | PLAN REVIEW COMMENTS | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | BUILDING | | | | | | 1) FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. THERE WAS ONLY ONE SET OF ENGINEERED TRUSS | | | DRAWINGS IN THE RE-SUBMITTAL PACKAGE. | | | | | | 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS THAT | | | ADEQUATELY REPRESENT THE STRUCTURE AND ITS COMPONENTS. | | | SEE COMMENTS #1 & #6 FROM 1ST REVIEW. FBC ENERGY | | | CONSERVATION SECT. 103.2.2 | | | | | | 3) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. SPECIFICALLY. | | | A) "STICKY BACK" ROOF TILE UNDERLAYMENT AS SPECIFIED ON | | | THE PLANS. | | | B) THE 6' X 8' OVERHEAD GARAGE DOOR. | | | C) THE PRODUCT APPROVAL FOR THE 3M, AH-160 FOAM ROOF | | | TILE ADHESIVE THAT HAD BEEN SUPERSEDED WAS REPLACED | | | WITH PRODUCT APPROVALS FOR 3M, RTA-1 (NOA 12-0228.18). | | | THE INSTALLATION NOTES REQUIRE THIS PRODUCT TO BE USED | | | WITH APPROVED ROOF TILES THAT LIST IT AS A METHOD OF | | | ATTACHMENT WITH A SPECIFIED MINIMUM ATTACHMENT | | | RESISTANCE. THE PRODUCT APPROVAL FOR THE ROOF TILE THAT | | | WAS SUBMITTED DOES NOT LIST THIS PRODUCT. FBC-R 301.1 | | | | | | IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-15 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-11 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2014-09-11 10:02:12 | PLAN REVIEW COMMENTS | | | | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | BUILDING | | | | | | 1) THE ENERGY COMPLIANCE FORM THAT WAS SUBMITTED FOR | | | THIS SINGLE FAMILY DWELLING IS WORST CASE AND DOES NOT | | | MATCH THE ORIENTATION OF THE STRUCTURE. THE HVAC LOAD | | | CALCULATIONS THAT WERE SUBMITTED SPECIFY THAT THE FRONT | | | DOOR FACES NORTHEAST. BASED ON THE SURVEY THAT WAS | | | SUBMITTED, THE FRONT DOOR FACES WEST. FBC ENERGY | | | CONSERVATION 403.6.1 | | | | | | 2) IDENTIFY THE ELEVATION THAT WILL BE USED FOR THIS | | | DWELLING AND CROSS OUT THE OTHERS. FBC 107.2.1 | | | | | | 3) FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | PROVIDE PRODUCT APPROVALS FOR THE ROOF TILE | | | UNDERLAYMENT AND THE 6 FOOT WIDE OVERHEAD GARAGE DOOR. | | | THE SLIDING GLASS DOOR NOA NO. 11- 1018.14 AND THE ROOF | | | TILE ADHESIVE NOA NO. 12-0228.18 HAVE BEEN SUPERSEDED. | | | THE FIXED WINDOW NOA NO. 13-0502.03 ONLY HAD 9 COPIES | | | OF THE FIRST PAGE. THE INSTALLATION DRAWINGS ARE | | | MISSING. | | | | | | 4) SPECIFY THE REQUIRED EMBEDMENT DEPTH OF THE 3/4" | | | DIA. ANCHOR BOLTS FOR THE COLUMN BASE IN DETAIL 1 ON | | | S-1. | | | | | | 5) FBC 109.3 THE VALUATION ON THE APPLICATION OF | | | $239,116.00 IS LOW AND HAS BEEN ADJUSTED TO $432,598.00 | | | BASED ON THE LATEST ICC VALUATION DATA. | | | | | | 6) THE ENERGY CALCULATIONS LIST INSULATED DOORS FOR THE | | | DOORS WITH GLASS INSERTS. THE SIMULATED PERFORMANCE | | | METHOD SECTION 405.5.1 REQUIRES ALL GLAZING IN DOORS TO | | | BE INCLUDED IN THE TOTAL WINDOW AREA. 405.5.3 DOORS | | | WITH GLAZING. FOR DOORS THAT ARE OPAQUE OR WHERE THE | | | GLASS IS LESS THAN ONE-THIRD OF THE AREA OF THE DOOR, | | | THE TOTAL DOOR AREA SHALL BE INCLUDED IN THE DOOR | | | CALCULATION. FOR UNLABELED SLIDING GLASS DOORS OR WHEN | | | GLASS AREAS IN DOORS IS GREATER THAN OR EQUAL TO | | | ONE-THIRD OF THE AREA OF THE DOOR, THE GLAZING PORTION | | | SHALL BE INCLUDED IN THE GLAZING CALCULATION AND THE | | | OPAQUE PORTION OF THE DOOR SHALL BE INCLUDED IN THE | | | DOOR CALCULATION. WHEN GLASS AREA IN DOORS IS GREATER | | | THAN OR EQUAL TO ONE-THIRD OF THE AREA OF THE DOOR, THE | | | DOOR SHALL BE INCLUDED IN THE GLAZING CALCULATION AS A | | | TOTAL FENESTRATION USING THE TESTED U-FACTOR AND SOLAR | | | HEAT GAIN COEFFICIENT. | | | | | | IN ORDER TO REDUCE PLAN REVIEW TIMES, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-11-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-12 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-12 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-09-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-13 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-13 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2015-03-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-18 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-06 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2015-03-09 09:12:40 | RE-SUBMITTAL SENT TO ROBERT MCDOUGAL FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2015-01-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-01-21 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-01-20 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2015-01-20 11:58:51 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2014-12-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-12-24 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-12-08 |
Time |
|
Sent To |
|
|
| Notes |
| 2014-12-23 18:05:18 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-12-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-08 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-08 |
Time |
18:06 |
Sent To |
|
|
| Notes |
| 2014-12-08 18:10:02 | SUBMITTAL OF PRODUCT APPROVALS WITH THE DESIGNER OF | | | RECORD REVIEW STAMP WERE PUT WITH DENIED PLANS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-11-15 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-11-15 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-30 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-15 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-31 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2014-08-04 09:59:38 | SENT TO R23. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
5 |
Status |
P |
Date |
2015-02-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-25 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-25 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2015-02-25 08:29:57 | MU2014-16458 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2015-01-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-01-21 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-01-21 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2015-01-21 14:52:24 | (REPEAT COMMENT) SUBMIT A COPY OF THE PAID IMPACT FEE | | | RECEIPT. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2014-12-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-23 |
Time |
18:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-23 |
Time |
18:05 |
Sent To |
|
|
| Notes |
| 2014-12-23 18:06:18 | (REPEAT COMMENT) SUBMIT A COPY OF THE PAID IMPACT FEE | | | RECEIPT. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2014-11-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-12 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-12 |
Time |
07:06 |
Sent To |
|
|
| Notes |
| 2014-11-12 17:09:53 | A COPY OF THE PAID IMPACT FEE RECEIPT IS REQUIRED. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-15 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-15 |
Time |
07:07 |
Sent To |
|
|
| Notes |
| 2014-09-15 07:08:20 | SUBMIT A COPY OF THE PAID IMPACT FEE RECEIPT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2015-03-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-18 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-18 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2015-01-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-01-21 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-01-21 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2015-01-21 14:50:54 | PLAN REVIEW COMMENTS | | | | | | | | | 4TH REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | MECHANICAL | | | | | | 1) BASED ON THE SURVEY THAT WAS SUBMITTED, THE FRONT | | | DOOR FACES WEST. ACCORDING TO THE LOAD CALCULATION THE | | | TOTAL COOLING LOAD IS 3.22 TONS FOR THE WHOLE HOUSE | | | WITH A WEST ORIENTATION. SYSTEM 1 HAS A TOTAL COOLING | | | LOAD OF 1.56 TONS AND SYSTEM 2 HAS A TOTAL COOLING LOAD | | | OF 1.66 TONS. FROM THE CALULATIONS IT APPEARS THAT BOTH | | | UNITS SHOULD BE 2 TONS AT MOST. THE PLANS SPECIFY A 2.5 | | | TON AND A 2 TON. THE 403.6.1.1 COOLING EQUIPMENT | | | CAPACITY. COOLING ONLY EQUIPMENT SHALL BE SELECTED SO | | | THAT ITS TOTAL CAPACITY IS NOT LESS THAN THE CALCULATED | | | TOTAL LOAD BUT NOT MORE THAN 1.15 TIMES GREATER THAN | | | THE TOTAL LOAD CALCULATED ACCORDING TO THE PROCEDURE | | | SELECTED IN SECTION 403.6, OR THE CLOSEST AVAILABLE | | | SIZE PROVIDED BY THE MANUFACTURER'S PRODUCT LINES. THE | | | CORRESPONDING LATENT CAPACITY OF THE EQUIPMENT SHALL | | | NOT BE LESS THAN THE CALCULATED LATENT LOAD. ( | | | ACCORDING TO THE LOAD CALCULATIONS A WEST FACING | | | BUILDING HAS THE LOWEST REQUIRED LOAD. WHY DO THE PLANS | | | SPECIFY EQUIPMENT THAT WAS DETERMINED TO BE WORST | | | CASE?) | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2014-12-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-23 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-23 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2014-12-23 14:22:43 | PLAN REVIEW COMMENTS | | | | | | | | | 3RD REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | MECHANICAL | | | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | 2) BASED ON THE SURVEY THAT WAS SUBMITTED, THE FRONT | | | DOOR FACES WEST. ACCORDING TO THE LOAD CALCULATION THE | | | TOTAL COOLING LOAD IS 3.22 TONS FOR THE WHOLE HOUSE | | | WITH A WEST ORIENTATION. SYSTEM 1 HAS A TOTAL COOLING | | | LOAD OF 1.56 TONS AND SYSTEM 2 HAS A TOTAL COOLING LOAD | | | OF 1.66 TONS. FROM THE CALULATIONS IT APPEARS THAT BOTH | | | UNITS SHOULD BE 2 TONS AT MOST. THE PLANS SPECIFY A 2.5 | | | TON AND A 2 TON. THE 403.6.1.1 COOLING EQUIPMENT | | | CAPACITY. COOLING ONLY EQUIPMENT SHALL BE SELECTED SO | | | THAT ITS TOTAL CAPACITY IS NOT LESS THAN THE CALCULATED | | | TOTAL LOAD BUT NOT MORE THAN 1.15 TIMES GREATER THAN | | | THE TOTAL LOAD CALCULATED ACCORDING TO THE PROCEDURE | | | SELECTED IN SECTION 403.6, OR THE CLOSEST AVAILABLE | | | SIZE PROVIDED BY THE MANUFACTURER'S PRODUCT LINES. THE | | | CORRESPONDING LATENT CAPACITY OF THE EQUIPMENT SHALL | | | NOT BE LESS THAN THE CALCULATED LATENT LOAD. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2014-11-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-12 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-12 |
Time |
07:06 |
Sent To |
|
|
| Notes |
| 2014-11-12 17:12:01 | PLAN REVIEW COMMENTS | | | | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | MECHANICAL | | | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. ( REPEAT COMMENT | | | ) | | | | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-20 |
Time |
|
Rev Time |
0.75 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-09-15 07:19:43 | PLAN REVIEW COMMENTS | | | | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | MECHANICAL | | | | | | 1) PROVIDE EQUIPMENT SIZING CALCULATIONS BASED ON THE | | | ACTUAL BUILDING ORIENTATION FOR THIS LOT, AS REQUIRED | | | BY SECTION 403.6 OF THE 2010 FBC - ENERGY CONSERVATION. | | | THE CALCULATIONS THAT WERE SUBMITTED AND THE EQUIPMENT | | | LISTED ON THE A/C PLAN ARE FOR WORST CASE. | | | | | | 2) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | IN ORDER TO REDUCE PLAN REVIEW TIMES, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | | 2014-08-20 14:50:55 | LOADED AND REVIEWED BY RBERGSMA |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-12-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-12-24 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-12-24 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-11-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-15 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-11-15 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2014-11-15 07:40:33 | 1)VENT FOR TUB & SHOWER IN MASTER BATH SHALL CONNECT | | | ABOVE THE CENTERLINE OF THE HORIZONTAL DRAIN PIPE.2010 | | | FBCR SEC.P3104.3. A FLAT DRY VENT AS DRAWN IS NOT | | | PERMITTED BY THE PLUMBING CODE.2ND REQUEST. | | | 2)THERE ARE TWO WET BAR OPTIONS SHOWN ON THE SANITARY | | | RISER BUT ONLY ONE SHOWN ON THE FLOOR PLAN AND IT IS | | | ALSO CROSSED OFF AS AN OPTION ON SHT. A-1. CLARIFY.2ND | | | REQUEST. | | | 3) THE FLOOR PLAN HAS A NOTE" STUB-OUT FOR FUTURE | | | SUMMER KITCHEN" BUT NOTHING IS SHOWN ON THE SANITARY | | | RISER. WPB AMEND TO 2010 FBC SEC.107.2.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-08-31 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-08-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-08-31 |
Time |
05:30 |
Sent To |
|
|
| Notes |
| 2014-08-31 05:50:39 | 1) REMOVE THE SHUTOFF VALVE SHOWN ON THE 3" BUILDING | | | DRAIN ON THE ISOMETRIC ON SHT. A-3.2010 FBCR SEC. | | | P3002.3.1. | | | 2) VENT FOR TUB & SHOWER IN MASTER BATH SHALL CONNECT | | | ABOVE THE CENTERLINE OF THE HORIZONTAL DRAIN PIPE.2010 | | | FBCR SEC.P3104.3 | | | 3) THERE ARE TWO WET BAR OPTIONS SHOWN ON THE SANITARY | | | RISER BUT ONLY ONE IS SHOWN ON THE FLOOR PLAN AND IT IS | | | ALSO CROSSED OFF AS AN OPTION ON SHT. A-1. CLARIFY. | | | 4) SHOW THE LENGTH DIMENSION OF EACH SECTION OF GAS | | | RISER TO CONFIRM THE TOTAL LONGEST LENGTH FROM THE | | | POINT OF DELIVERY TO THE MOST REMOTE OUTLET. INCLUDE | | | ALL DROPS AND STUB-OUTS. WPB ADMIN. AMEND. TO 2010 FBC | | | SEC. 107.2.1. | | | 5) THE GAS RISER IS SHOWING 2 1/2 " VALVES ON 1" GAS | | | LINES. CLARIFY. | | | 6) I CALCULATED 247,000 BTU'S AND THE GAS LOAD ON THE | | | PLAN STATES 265.000 BTU'S CLARIFY. | | | 7) NOTE ON SHT. A-3 STATES "SEE GAS PLAN AT SHEET E-1." | | | THERE IS NO GAS PLAN ON E-1 EXCEPT FOR THE GAS METER | | | AND A NOTE THAT STATES" 1 1/4" GAS UP TO ATTIC" AND IT | | | SHOWS THE GAS APPLIANCES. CLARIFY. | | | 8) SHT.A-1-GARAGE-NOTE REFERS TO 2010 FBC SEC. 3034 FOR | | | PROTECTION OF WATER HEATER. THERE IS NO SUCH CODE | | | SECTION IN THE BUILDING CODE OR IN THE RESIDENTIAL | | | CODE. CLARIFY. | | | 9) SHT.A-3-THE GAS NOTES REFER TO AN LP GAS SYSTEM AND | | | ALSO NATURAL GAS AND THE SPECIFIC GRAVITY YOU HAVE | | | LISTED FOR THE TYPE OF GAS IS FOR LP GAS AND A GAS | | | METER AND A CONNECTION TO THE GAS COMPANY IS SHOWN ON | | | THE RISER DIAGRAM. WHAT IS IT, LP OR NATURAL? REMOVE | | | ANY NOTES THAT ARE NOT APPLICABLE TO THE CORRECT TYPE | | | OF GAS. | | | 10) PROVISIONS SHALL BE MADE FOR THERMAL EXPANSION | | | CONTROL OF THE WATER SUPPLY SYSTEM IN ACCORDANCE WITH | | | 2010 FBCR SEC. P2903.4 & P2903.4.2.DUE TO THE | | | INSTALLATION OF A BACKFLOW PREVENTER FOR THE IRRIGATION | | | SYSTEM. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE- | | | CHIEF PLUMBING INSPECTOR | | | TEL:561-805-6692 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2014-11-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-13 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-13 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2014-11-13 15:13:57 | ROOFING MATERIALS: | | | ENTEGRA ESTATE "S" TILE - NOA NO. 11-0510.02 (ATTACHED | | | WITH 2-10D RING SHANK NAILS) | | | 3M FOAM ROOF TILE ADHESIVE RTA-1 | | | NO PRODUCT APPROVAL FOR UNDERLAYMENT WAS SUBMITTED. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-11-03 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-11-03 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-11-03 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-08-06 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-08-06 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-08-06 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2014-08-06 16:29:28 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 8/6/14 | | | | | | ITEMS TO BE REVISED/SUBMITTED: | | | | | | 1. A SEPARATE LANDSCAPE PERMIT IN CONFORMANCE WITH | | | ARTICLE XIV SHALL BE SUBMITTED. (NOTE: ZLDR SEC. | | | 94-442(B)(2)A. - FOR SINGLE-FAMILY DWELLING UNITS, AT | | | LEAST ONE SHADE, FLOWERING, OR FRUIT TREE SHALL BE | | | PLANTED FOR EACH 1,200 SQUARE FEET OF OPEN SPACE OR | | | PORTION THEREOF. FOR SINGLE-FAMILY DWELLING UNITS, AT | | | LEAST ONE SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE | | | FEET OF OPEN SPACE OR PORTION THEREOF. PLEASE ADJUST | | | CALCULATIONS TABLE.) | | | | | | OTHER COMMENTS: | | | | | | 2. SEPARATE PERMIT WILL BE REQUIRED FOR THE DRIVEWAY. | | | | | | 3. NOTE ADDED TO PLAN THAT MECHANICAL EQUIPMENT (A/C | | | UNIT) MUST BE AT LEAST 4' FROM THE PROPERTY LINE. | | | | | | 4. NOTE ADDED TO PLAN THAT PRIVACY WALL NOT UNDER ROOF | | | CANNOT EXCEED 6' IN HEIGHT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | | |
|
|