Plan Review Details - Permit 14071153
| Plan Review Stops For Permit 14071153 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-04 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-04 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2014-08-04 09:28:36 | BUILDING PLAN REVIEW | | | PERMIT: 14071153 | | | ADD: 8130 N JOG RD | | | CONT: ALL SITE | | | TEL: (561)848-1110 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. AUG. 04/ 2014 | | | ACTION: DENIED | | | | | | 1) PLANS SUBMITTED ARE COPIES OF ARCHITECT REG. | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. FL ADMIN | | | CODE 61G16.003 ARCHITECTS. | | | | | | 2) THE SUBMITTED PLANS ARE ALSO PLANS THAT HAVE BEEN | | | REDUCED IN SIZE. 107.2.1.4 QUALITY OF BUILDING PLANS. | | | BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH | | | SCALE. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | | DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND | | | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS | | | RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH | | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | | OTHER ITEMS RELATED TO RECORDS MANAGEMENT. | | | | | | 3) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.3.5 | | | MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE | | | EXAMINATION OF THE DOCUMENTS BY THE BUILDING OFFICIAL | | | SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA AND | | | DOCUMENTS: | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | FLOOR PLAN WITH THE INTENDED SCOPE OF WORK WALL LAY OUT | | | OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | OCCUPANCY LOAD | | | GROSS | | | NET | | | MEANS OF EGRESS | | | EXIT ACCESS | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-09-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-04 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-04 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2014-09-04 10:33:15 | DATE: 9/4/2014 | | | PROJECT: PBSO WEIGHT ROOM | | | PERMIT#: 14071153 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL. WPB AMENDMENTS TO THE FBC | | | 107.2.1. THERE IS NO ELECTRICAL INFORMATION ON THE | | | SUBMITTAL TO REVIEW. SEE BELOW FOR THE MINIMUM PLAN | | | REVIEW CRITERIA FOR ELECTRICAL WORK: | | | A.) 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, SECTION 107.3.5 MINIMUM PLAN REVIEW | | | CRITERIA FOR BUILDINGS.107.3.5.1.2 ELECTRICAL | | | 1. ELECTRICAL: WIRING, SERVICES, FEEDERS AND BRANCH | | | CIRCUITS, OVERCURRENT PROTECTION, GROUNDING, WIRING | | | METHODS AND MATERIALS, GFCI'S | | | 2. EQUIPMENT | | | 3. SPECIAL OCCUPANCIES | | | 4. EMERGENCY SYSTEMS | | | 5. COMMUNICATION SYSTEMS | | | 6. LOW VOLTAGE | | | 7. LOAD CALCULATIONS | | | 8. DESIGN FLOOD ELEVATION | | | | | | 2) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. WPB AMENDMENTS | | | TO FBC 107.2.1. | | | THE PLANS SUBMITTED SHALL BE SIGNED BY THE DESIGN | | | PROFESSIONAL RESPONSIBLE FOR THE DESIGN. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-07-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-07-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-07-31 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2014-07-31 11:26:12 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | IF APPLICABLE: | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-04 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-30 |
Time |
18:10 |
Sent To |
|
|
| Notes |
|
|
|