| Plan Review Stops For Permit 14071145 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-09-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-05 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-05 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-04 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-04 |
Time |
06:55 |
Sent To |
Z |
|
| Notes |
| 2014-08-04 08:40:17 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE CONSTRUCTION TYPE AND OCCUPANCY GROUP LISTED ON | | | SHEET S-1 ARE INCORRECT. THIS PROJECT IS CONSTRUCTION | | | TYPE VB AND THE OCCUPANCY GROUP IS R-3. FBC 602 & 302 | | | | | | 2) SPECIFY THE WIND DESIGN CRITERIA ON THE PLANS. THE | | | WIND SPEED IS 170 MPH VULT, THE EXPOSURE CATEGORY IS C | | | AND THE MEAN ROOF HEIGHT IS LESS THAN 25 FEET. FBCR | | | 301.2.1 | | | | | | 3) SPECIFY THE FASTENER AND SPACING FOR ATTACHING THE | | | WOOD BUCKS TO THE SUBSTRATE. FBCR 612.10.2 | | | | | | 4) PROVIDE A BUCK FASTENING DETAIL AT THE MASONRY | | | OPENINGS FOR THE SLIDING GLASS DOORS. FBCR 612.10.2 | | | | | | 5) SHOW COMPLIANCE WITH 2010 FBC ENERGY CONSERVATION | | | SECTION 101.4.3 & 103.2 BY SUBMITTING THE PROPER | | | CONSTRUCTION DOCUMENTS. SEE RESIDENTIAL BUILDING FORMS | | | 402 OR 405. | | | | | | 6) SHOW COMPLIANCE WITH FBCR 318 FOR PROTECTION AGAINST | | | TERMITES. | | | | | | 7) SHOW COMPLIANCE WITH FBCR 703.6.3 FOR THE REQUIRED | | | BOND BREAK BETWEEN THE EXTERIOR STUCCO AND THE | | | WATER-RESISTIVE BARRIER. | | | | | | 8) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE NEW | | | IMPACT RATED WINDOWS, SLIDING GLASS DOORS AND THE | | | SIMPSON CONNECTORS AS REQUIRED BY DCA RULE 9N-3. | | | | | | 9) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | | THE PROJECT. CITY AMENDMENTS 107.3.4.1 | | | | | | 10) PLEASE SUBMIT A SIGNED COPY OF THE CONTRACT FOR | | | THIS PROJECT TO VERIFY THE VALUATION. FOR PERMITTING | | | PURPOSES THE VALUATION SHALL BE THE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, ARCHITECTURAL AND DESIGN | | | FEES, OVERHEAD AND PROFIT PER CITY AMENDMENTS 109.3. | | | | | | 11) IN ORDER TO REDUCE REVIEW TIME, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW ITEMS | | | HAS BEEN ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-04 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-04 |
Time |
06:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-09-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-08 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-08 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2014-09-08 12:38:48 | TO RMCDOUGA DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-05 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-28 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2014-08-29 11:06:07 | SENT TO R MCDOUGALS DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-05 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-30 |
Time |
17:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2014-09-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-08 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-08 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2014-09-08 12:50:50 | MU2014-19895, NO FEES WERE OWED. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2014-09-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-05 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-05 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2014-09-05 15:46:06 | IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-04 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-04 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2014-08-04 06:59:42 | IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-04 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-04 |
Time |
06:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-04 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-04 |
Time |
06:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2014-08-04 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2014-08-04 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2014-08-01 09:55:29 | 8/1/14 |
|
|