Plan Review Details - Permit 14070836
| Plan Review Stops For Permit 14070836 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-07-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-26 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-26 |
Time |
07:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-07-28 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-28 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-28 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-07-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-07-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-07-23 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2014-07-24 09:47:58 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE PROPOSED MAIN ENTRANCE DOOR IS SHOWN TO BE SWINGING | | | INTO THE EXISTING EXIT CORRIDOR AND ENCROACHES ON AND | | | RESTRICTS EXITING ALONG THE CORRIDOR. THE MAIN ENTRANCE | | | DOOR SHALL SWING INTO THE OFFICE SPACE. | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-07-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-07-29 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-07-22 |
Time |
17:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-07-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-07-29 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-07-29 |
Time |
06:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-07-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-26 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-26 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2014-07-26 08:46:30 | PLUMBING PROVISO: | | | AIR ADMITTANCE VALVE TO COMPLY WITH 2010 FBC-P 917.3.1 | | | LOCATION OF BRANCH. | | | THE HORIZONTAL BRANCH DRAIN SHALL CONNECT TO THE | | | DRAINAGE STACK OR BUILDING DRAIN A MAXIMUM OF FOUR | | | BRANCH INTERVALS FROM THE TOP OF THE STACK. | | | MUST BE USED WITHIN THE TOP 4 FLOORS OF THE BUILDING. | | | SEE EXCEPTION. |
|
|
|