Plan Review Details - Permit 14070782
Plan Review Stops For Permit 14070782
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-08-04 Cont ID  
Sent By jwitmer Date 2014-08-04 Time 06:28 Rev Time 0.00
Received By jwitmer Date 2014-08-04 Time 06:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-08-22 Cont ID  
Sent By rlecky Date 2014-08-22 Time 12:49 Rev Time 0.00
Received By rlecky Date 2014-08-22 Time 12:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-08-20 Cont ID  
Sent By rlecky Date 2014-08-20 Time 14:34 Rev Time 0.00
Received By rlecky Date 2014-08-20 Time 14:22 Sent To  
Notes
2014-08-20 14:35:34 
 14070782
 3300 S. DIXIE HWY #1
 INTERIOR RENOVATION ?THE UPS STORE?
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS.
  
 SHOW THE LOCATION OF THE ELECTRICAL SERVICE WITH
 DISCONNECT ON THE SITE PLAN. PROVIDE AN ELECTRIC
 SERVICE RISER PAN WHICH VERIFIES THE ELECTRICAL SERVICE
 MAINS SERVING THIS BUILDING ARE SIX OR LESS AND GROUPED
 IN ONE LOCATION. SHOW ALL METERS, GROUNDING, MAIN
 DISCONNECTS AND PANEL BOARDS FOR THE BUILDING SERVICE
 INCLUDING ALL OTHER EXISTING OCCUPANCIES REQUIRING
 ELECTRICAL SERVICE.
 NEC 230.2, 230.71, 230.72
  
 PROVIDE A MAIN SERVICE DISCONNECT AT A READILY
 ACCESSIBLE LOCATION NEAREST THE POINT OF ENTRANCE OF
 THE SERVICE CONDUCTORS. NEC 230.70
  
 VERIFY THE ELECTRICAL SERVICE DISCONNECTING MEANS HAS A
 FAULT CURRENT RATING THAT IS SUFFICIENT AT NOMINAL
 CIRCUIT VOLTAGE FOR THE CURRENT THAT MUST BE
 INTERRUPTED. NEC 110.9
  
  
 ROBERT LECKY, CBO
 ELECTRICAL PLANS REVIEW
 561-373-3701
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-07-30 Cont ID  
Sent By pleduc Date 2014-07-30 Time   Rev Time 0.00
Received By pleduc Date 2014-07-30 Time 13:15 Sent To  
Notes
2014-07-30 13:26:52THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 ADD/PROVIDE FOR AN ADDITIONAL EMERGENCY LIGHT IN THE
 CENTER AREA OF THE REAR PACKAGING SPACE.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-08-22 Cont ID  
Sent By rlecky Date 2014-08-22 Time 12:49 Rev Time 0.00
Received By rlecky Date 2014-08-22 Time 11:32 Sent To  
Notes
2014-08-22 11:33:18INCOMING SENT TO R. LECKY'S DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-08-20 Cont ID  
Sent By rlecky Date 2014-08-20 Time 14:35 Rev Time 0.00
Received By rlecky Date 2014-08-20 Time 14:35 Sent To  
Notes
2014-07-23 18:49:32B15

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2014-08-04 Cont ID  
Sent By jwitmer Date 2014-08-04 Time 06:28 Rev Time 0.00
Received By jwitmer Date 2014-08-04 Time 06:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2014-08-04 Cont ID  
Sent By jwitmer Date 2014-08-04 Time 06:28 Rev Time 0.00
Received By jwitmer Date 2014-08-04 Time 06:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2014-08-04 Cont ID  
Sent By jwitmer Date 2014-08-04 Time 06:29 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***