|
 |
 |
 |
 |
 |
Plan Review Details - Permit 14070782
| Plan Review Stops For Permit 14070782 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-04 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-04 |
Time |
06:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-08-22 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-08-22 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-08-22 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-08-20 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-08-20 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-08-20 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2014-08-20 14:35:34 | | | | 14070782 | | | 3300 S. DIXIE HWY #1 | | | INTERIOR RENOVATION ?THE UPS STORE? | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS. | | | | | | SHOW THE LOCATION OF THE ELECTRICAL SERVICE WITH | | | DISCONNECT ON THE SITE PLAN. PROVIDE AN ELECTRIC | | | SERVICE RISER PAN WHICH VERIFIES THE ELECTRICAL SERVICE | | | MAINS SERVING THIS BUILDING ARE SIX OR LESS AND GROUPED | | | IN ONE LOCATION. SHOW ALL METERS, GROUNDING, MAIN | | | DISCONNECTS AND PANEL BOARDS FOR THE BUILDING SERVICE | | | INCLUDING ALL OTHER EXISTING OCCUPANCIES REQUIRING | | | ELECTRICAL SERVICE. | | | NEC 230.2, 230.71, 230.72 | | | | | | PROVIDE A MAIN SERVICE DISCONNECT AT A READILY | | | ACCESSIBLE LOCATION NEAREST THE POINT OF ENTRANCE OF | | | THE SERVICE CONDUCTORS. NEC 230.70 | | | | | | VERIFY THE ELECTRICAL SERVICE DISCONNECTING MEANS HAS A | | | FAULT CURRENT RATING THAT IS SUFFICIENT AT NOMINAL | | | CIRCUIT VOLTAGE FOR THE CURRENT THAT MUST BE | | | INTERRUPTED. NEC 110.9 | | | | | | | | | ROBERT LECKY, CBO | | | ELECTRICAL PLANS REVIEW | | | 561-373-3701 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-07-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-07-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-07-30 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2014-07-30 13:26:52 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | ADD/PROVIDE FOR AN ADDITIONAL EMERGENCY LIGHT IN THE | | | CENTER AREA OF THE REAR PACKAGING SPACE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-08-22 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-08-22 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-08-22 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2014-08-22 11:33:18 | INCOMING SENT TO R. LECKY'S DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-08-20 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-08-20 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-08-20 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-04 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-04 |
Time |
06:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-04 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-04 |
Time |
06:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-04 |
Time |
06:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |