| Plan Review Stops For Permit 14070781 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2014-11-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-11-03 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-11-03 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2014-11-03 17:46:33 | SEPARATE PERMIT REQUIRED FOR ELECTRIC, PLUMBING | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2014-10-22 |
|
|
Cont ID |
|
| Sent By |
SHILL |
Date |
2014-10-22 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-10-22 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2014-10-22 17:10:48 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | COMMENTS ARE FROM PREVIOUS LIST. A RESPONSE LETTER WAS | | | PROVIDED BUT THE PLANS WERE NOT REVISED. | | | | | | PRIOR TO RESUBMITTAL, CONTRACTOR IS TO VERIFY THE | | | FOLLOWING - ***DO NOT RESUBMIT UNLESS COMMENTS ARE | | | ADDRESSED*** | | | | | | VERIFY THAT DESIGN PROFESSIONALS HAVE INCLUDED FLOOD | | | DESIGN CRITERIA FOR ALL PROPOSED IMPROVEMENTS WHICH ARE | | | BELOW 7'. | | | | | | THIS INCLUDES THE GATE AND THE HARDSCAPE. THE SAME | | | PLANS WERE SUBMITTED, RESPONSE LETTER STATES THAT "ALL | | | NEW ELECTRICAL FIXTURES AND EQUIPMENT TO BE MOUNTED | | | ABOVE 7' BFE. THE GATE AND HARDSCAPE ARE TO BE BELOW | | | 7'. THEY ARE TO RESIST FLOOD LOADS, AND PLANS NEED TO | | | BE REVISED TO STATE SUCH. | | | | | | SEE PREVIOUS COMMENTS FOR ELEVATION CERTIFICATE. THE | | | SAME ELEVATION CERTIFICATE WAS SUBMITTED. IT IS NOT AN | | | ORIGINAL. | | | | | | FOR YOUR CONVENIENCE, THE PREVIOUS COMMENT LIST IS | | | BELOW: | | | | | | | | | 1. PLEASE REVISE THE ELEVATION CERTIFICATE IN THE | | | FOLLOWING FIELDS: | | | | | | B6, FIRM INDEX DATE, 3/1/1979 | | | B7, FIRM PANEL, 3/1/1979 | | | SECTION D, MARK BOX REGARDING LATITUDE/LONGITUDE | | | SECTION D, RAISED IMPRESSION SEAL REQUIRED | | | SECTION D, COMMENTS, INCLUDE SOURCE OF | | | LATITUDE/LONGITUDE PER INSTRUCTIONS | | | | | | 2. COMMENT FROM PREVIOUS LIST: | | | | | | BASED ON THE SPOT ELEVATIONS ON THE SURVEY, THE | | | PROPOSED IMPROVEMENT IS BELOW THE BASE FLOOD ELEVATIONS | | | AND ALL IMPROVEMENTS ARE TO BE DESIGNED TO RESIST FLOOD | | | LOADS FBC 2010 RESIDENTIAL 301. FIXTURES AND EQUIPMENT | | | ARE TO BE ABOVE BFE (7') OR TO BE FLOOD RESISTANT. GAS | | | FIXTURES ARE PROPOSED BELOW BFE. PLEASE REVISE PLAN OR | | | SUBMIT DATA WHICH DEMONSTRATES THAT PROPOSED FIXTURES | | | WILL RESIST FLOOD LOADS. | | | | | | 2ND REVIEW, I WAS UNABLE TO FIND ANYWHERE IN THE PLAN | | | THAT THE DESIGNER INCLUDES FLOOD LOADS IN DESIGN | | | CRITERIA. PLEASE REVISE PLAN. WHEN RESUBMITTING, SWAP | | | OUT SHEETS WHICH HAVE CHANGED SO THERE ARE TWO COMPLETE | | | COLLATED SETS FOR PERMIT ISSUANCE. A RESPONSE LETTER | | | INDICATING HOW THIS ITEM HAS BEEN ADDRESSED WOULD BE | | | HELPFUL. IT APPEARS THAT NEW SHEETS WERE SUBMITTED, NEW | | | INFORMATION, BUT NOT CLEAR HOW THE REQUIREMENT THAT THE | | | PROPOSED IMPROVEMENT RESIST FLOOD LOADS IF BELOW BASE | | | FLOOD ELEVATION OF 7' HAS BEEN MET. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-25 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-09-25 |
Time |
17:49 |
Sent To |
|
|
| Notes |
| 2014-09-25 18:21:27 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PLEASE REVISE THE ELEVATION CERTIFICATE IN THE | | | FOLLOWING FIELDS: | | | | | | B6, FIRM INDEX DATE, 3/1/1979 | | | B7, FIRM PANEL, 3/1/1979 | | | SECTION D, MARK BOX REGARDING LATITUDE/LONGITUDE | | | SECTION D, RAISED IMPRESSION SEAL REQUIRED | | | SECTION D, COMMENTS, INCLUDE SOURCE OF | | | LATITUDE/LONGITUDE PER INSTRUCTIONS | | | | | | 2. COMMENT FROM PREVIOUS LIST: | | | | | | BASED ON THE SPOT ELEVATIONS ON THE SURVEY, THE | | | PROPOSED IMPROVEMENT IS BELOW THE BASE FLOOD ELEVATIONS | | | AND ALL IMPROVEMENTS ARE TO BE DESIGNED TO RESIST FLOOD | | | LOADS FBC 2010 RESIDENTIAL 301. FIXTURES AND EQUIPMENT | | | ARE TO BE ABOVE BFE (7') OR TO BE FLOOD RESISTANT. GAS | | | FIXTURES ARE PROPOSED BELOW BFE. PLEASE REVISE PLAN OR | | | SUBMIT DATA WHICH DEMONSTRATES THAT PROPOSED FIXTURES | | | WILL RESIST FLOOD LOADS. | | | | | | 2ND REVIEW, I WAS UNABLE TO FIND ANYWHERE IN THE PLAN | | | THAT THE DESIGNER INCLUDES FLOOD LOADS IN DESIGN | | | CRITERIA. PLEASE REVISE PLAN. WHEN RESUBMITTING, SWAP | | | OUT SHEETS WHICH HAVE CHANGED SO THERE ARE TWO COMPLETE | | | COLLATED SETS FOR PERMIT ISSUANCE. A RESPONSE LETTER | | | INDICATING HOW THIS ITEM HAS BEEN ADDRESSED WOULD BE | | | HELPFUL. IT APPEARS THAT NEW SHEETS WERE SUBMITTED, NEW | | | INFORMATION, BUT NOT CLEAR HOW THE REQUIREMENT THAT THE | | | PROPOSED IMPROVEMENT RESIST FLOOD LOADS IF BELOW BASE | | | FLOOD ELEVATION OF 7' HAS BEEN MET. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-07-23 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-07-23 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2014-07-23 13:54:29 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. SURVEY STATES THIS IS IN A B ZONE, BUT IT APPEARS TO | | | BE LOCATED IN AN A ZONE. PLEASE REVISE SURVEY TO SHOW | | | LINE OF FLOOD ZONE A. | | | | | | 2. THE PERMIT FOR THE ELEVATOR WAS ISSUED WITH PROVISO | | | THAT AN ELEVATION CERTIFICATE BE SUBMITTED. THIS WAS A | | | CONDITION OF ISSUANCE OF PERMIT. PLEASE SUBMIT AT THIS | | | TIME. | | | | | | 3. BASED ON THE SPOT ELEVATIONS ON THE SURVEY, THE | | | PROPOSED IMPROVEMENT IS BELOW THE BASE FLOOD ELEVATIONS | | | AND ALL IMPROVEMENTS ARE TO BE DESIGNED TO RESIST FLOOD | | | LOADS FBC 2010 RESIDENTIAL 301. FIXTURES AND EQUIPMENT | | | ARE TO BE ABOVE BFE (7') OR TO BE FLOOD RESISTANT. GAS | | | FIXTURES ARE PROPOSED BELOW BFE. PLEASE REVISE PLAN OR | | | SUBMIT DATA WHICH DEMONSTRATES THAT PROPOSED FIXTURES | | | WILL RESIST FLOOD LOADS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2014-10-22 |
|
|
Cont ID |
|
| Sent By |
DHAYES |
Date |
2014-10-22 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-10-22 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2014-10-22 17:30:21 | SEPARATE PERMIT REQUIRED | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-09-25 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-25 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-25 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2014-09-25 15:32:17 | DATE: 9/25/2014 | | | PROJECT: PARMALEE RESIDENCE | | | PERMIT#: 14070781 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) WPB AMENDMENTS TO FBC- 107.3.5.3 MINIMUM PLAN REVIEW | | | CRITERIA RESIDENTIAL; PROVIDE AN ELECTRIC SERVICE RISER | | | WITH WIRE SIZES, CONDUIT AND GROUNDING DETAIL. COMPLETE | | | LOAD CALCULATIONS, PANEL SCHEDULES, FIXTURE SCHEDULE, | | | SYMBOLS KEY LEGEND, AND INDICATE ALL CONDUIT AND WIRE | | | SIZSE FOR CIRCUITS ON SITE PLAN AND FLOOR PLAN | | | RESPECTIVELY. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-09-16 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-09-16 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-09-16 |
Time |
15:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-07-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-07-22 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-07-22 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
Zoning |
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-12-10 |
Time |
16:29 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
|
Date |
2014-11-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
|
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-10-31 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2014-10-31 16:02:05 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-10-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-10-22 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-10-17 |
Time |
18:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-25 |
Time |
18:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-09-03 |
Time |
17:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-07-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-07-23 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-07-23 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2014-10-22 |
|
|
Cont ID |
|
| Sent By |
TKLARGE |
Date |
2014-10-22 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-10-22 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2014-10-22 17:31:27 | SEPARATE PERMIT REQUIRED | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-09-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-25 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-25 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2014-09-25 10:41:52 | WPB ADMIN. AMEND. TO 2010 FBC 107.2.1 | | | 1) THE PLANS REFER TO IRRIGATION AND DRAINAGE TO THE | | | URNS. IRRIGATION SHALL BE UNDER A SEPARATE PERMIT. WHAT | | | TYPE OF DRAINAGE WILL BE PROVIDED? | | | 2) SUBMIT PIPING PLANS FOR THE FOUNTAINS AND MANUF. | | | SPECIFICATION SHEETS FOR THE FOUNTAIN EQUIPMENT. | | | 3) SUBMIT DETAILS ON THE FOUNTAINS. | | | 4) SHT. P-1 SHOWS THE FOUNTAINS DRAINING INTO THE | | | SANITARY SYSTEM. THIS MAY BE NOT PERMITTED BY THE | | | CITY'S UTILITY DEPT. SUBMIT A RISER DIAGRAM SHOWING THE | | | CONNECTION TO THE FOUNTAINS. | | | 5) SUBMIT MANUF. SPECIFICATIONS ON THE BACKFLOW | | | PREVENTER AND THE AUTOFILL. | | | 6) A SEPARATE PERMIT IS REQUIRED FOR THE GAS WORK TO BE | | | DONE. SUBMIT MANUF. SPECS. FOR THE GAS COMPONENTS AND A | | | GAS DRAWING AND OTHER APPLICABLE DOCUMENTS WHEN | | | APPLYING FOR THE GAS PERMIT. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
FMITTNER |
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-09-16 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-09-16 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-09-16 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2014-09-16 15:26:24 | NEWLY SUPPLIED DETAILS SHOW GATES IN EXCESS OF 6"-7" | | | (CODE PERMITS 6' PLUS 10% FOR DECORATIVE ELEMENTS). | | | ALSO GATE LOCATION ON DETAILS IS NOT INDICATED HOW IT | | | CORRESPONDS TO SITE PLAN. QUESTIONS CONTACT FRIEDERIKE | | | MITTNER 822-1457. | | | | | | PUT BACK IN BOX R 27 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-07-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-07-22 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-07-22 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2014-07-22 09:37:38 | 4' MAX HEIGHT IN FIRST 25' FROM FLAGLER DRIVE. | | | DECORATIVE ELEMENTS NOT TO EXCEED 10% OF MAX HEIGHT | | | INCLUDING URNS. |
|
|