Plan Review Details - Permit 14070773
| Plan Review Stops For Permit 14070773 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-08-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-05 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-05 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-09-18 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-18 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-18 |
Time |
12:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-08-28 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-08-28 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-28 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2014-08-28 10:58:24 | DATE: 8/28/2014 | | | PROJECT: MORSE LIFE | | | PERMIT#: DATE: 8/28/2014 | | | PROJECT: MORSE LIFE | | | PERMIT#: 14070773 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) THE CIRCUIT FEEDING T-13 TO PANEL L-22 IS OVERSIZED. | | | REVISE THE OCPD AND FEEDER ACCORDINGLY. | | | | | | 2) PROVIDE THE PANEL SCHEDULES WITH LOAD CALCULATIONS | | | FOR PANEL MDP PANEL H7 AND PANEL L22 IN ORDER TO VERIFY | | | THE LOADS, CIRCUITS, OCPD'S FEEDING THE PANELS AFFECTED | | | IN THIS RENNOVATION PROJECT. | | | | | | 3) INDICATE THE LOCATIONS OF THE PANELS AFFECTED IN | | | THIS RENNOVATION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT | | | /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM | | | ITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-07-30 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-07-30 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-07-30 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2014-07-30 11:49:31 | 4847 FRED GLADSTONE DRIVE | | | PERMIT #14070773 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SHEET A3.1: INDICATE THE SMOKE/FLAME SPREAD RATING OF | | | THE ACOUSTICAL WALL PANELS. INTERIOR WALL AND CEILING | | | FINISH MATERIALS SHALL BE CLASS A OR IN GENERAL | | | ASSEMBLY AREAS HAVING AN OCCUPANT LOAD OF MORE THAN 300 | | | PERSONS ANS SHALL BE CLASS A, B OR C IN ASSEMBLY AREAS | | | HAVING OCCUPANT LOADS OF 300 OR FEWER. | | | | | | SHEET A4: VERIFY EXIT/EXIT ACCESS DOORS EQUIPPED WITH | | | PANIC HARDWARE. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2014-09-18 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-09 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-08-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2014-08-28 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2014-07-24 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2014-08-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-08-12 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-08-12 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2014-08-12 11:25:32 | NO MECHANICAL PLANS SUBMITTED AT THIS TIME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2014-09-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-19 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-18 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-08-18 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-08-18 |
Time |
16:38 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2014-08-18 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2014-07-25 10:36:50 | 7/25/14 |
|
|
|
Account Summary | Usage Policy | Privacy Policy