Plan Review Details - Permit 14070544
Plan Review Stops For Permit 14070544
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-09-16 Cont ID  
Sent By rmcdouga Date 2014-09-16 Time 13:10 Rev Time 0.00
Received By rmcdouga Date 2014-09-16 Time 12:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-08-05 Cont ID  
Sent By rmcdouga Date 2014-08-05 Time 13:31 Rev Time 0.00
Received By rmcdouga Date 2014-08-05 Time 13:31 Sent To  
Notes
2014-08-05 13:37:102010 FBC
  
 DENIED BY BUILDING
  
 1) THE WIND SPEED ON THE PLANS IS SPECIFIED AS 140 MPH.
 THE WIND SPEED FOR THIS PROJECT IS 170 MPH VULT FOR
 RISK CATEGORY II OR 155 MPH FOR RISK CATEGORY I PER FBC
 1609.1.1. PLEASE REVISE PLANS.
  
 2) THE VALUATION FOR THIS PROJECT IS SPECIFIED AS
 $2475.00 ON THE APPLICATION. THIS IS TOO LOW. THE
 VALUATION WAS $10,640.00 FOR THE PERMIT THAT THIS ONE
 IS REPLACING. SUBMIT A COPY OF THE SIGNED CONTRACT FOR
 THE ENTIRE SCOPE OF WORK. FOR PERMITTING PURPOSES THE
 VALUATION IS THE TOTAL REPLACEMENT COST, INCLUDING ALL
 ENGINEERING AND DESIGN FEES, FABRICATION AND
 INSTALLATION COSTS AND OVERHEAD AND PROFIT PER CITY
 AMENDMENT 109.3.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-09-16 Cont ID  
Sent By dhayes Date 2014-09-16 Time 13:26 Rev Time 0.00
Received By dhayes Date 2014-09-16 Time 13:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-07-29 Cont ID  
Sent By dhayes Date 2014-07-29 Time 12:43 Rev Time 0.00
Received By dhayes Date 2014-07-29 Time 12:43 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-09-16 Cont ID  
Sent By rmcdouga Date 2014-09-16 Time 13:10 Rev Time 0.00
Received By rmcdouga Date 2014-09-16 Time 12:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-08-05 Cont ID  
Sent By rmcdouga Date 2014-08-05 Time 14:25 Rev Time 0.00
Received By rmcdouga Date 2014-07-16 Time 18:20 Sent To  
Notes
2014-07-16 18:20:40SENT TO ZONING BOX.

Review Stop Z ZONING
Rev No 2 Status P Date 2014-09-16 Cont ID  
Sent By sgraham Date 2014-09-16 Time 13:01 Rev Time 0.00
Received By sgraham Date 2014-09-16 Time 13:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2014-07-17 Cont ID  
Sent By sgraham Date 2014-07-17 Time 09:41 Rev Time 0.00
Received By sgraham Date 2014-07-17 Time 09:41 Sent To E
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy