| Plan Review Stops For Permit 14070510 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-29 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-29 |
Time |
16:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-21 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-19 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2014-07-21 14:43:12 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) ON SHEET A3.1, THE REAR ELEVATION HAS ONE OF THE B | | | UNITS LABELED AS UNIT E. PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-08-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-07 |
Time |
17:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-07 |
Time |
17:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-29 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-29 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2014-07-29 18:22:04 | 2010 FBC / 2008 NEC | | | | | | DENIED BY ELECTRIC | | | | | | 1) SEVERAL OF THE ELECTRICAL LOAD CALCULATIONS ON SHEET | | | E3.0 ARE LABELED WITH INCORRECT UNIT LETTERS. UNIT "C" | | | (1613 SF) IS LABELED AS UNIT "B". UNIT "D" (1681 SF) IS | | | LABELED AS UNIT "C". UNIT "F" (1765 SF) IS LABELED AS | | | UNIT "C". PLEASE CORRECT. CITY AMENDMENTS 107.2.1 | | | | | | 2) THE ELECTRIC SERVICE CALCULATION FOR UNIT "D" HAS 10 | | | KW LISTED FOR THE AHU / HEAT STRIP AND IT SHOULD BE 8 | | | KW. PLEASE CORRECT AND ADJUST THE TOTAL. NEC 220 | | | | | | IN ORDER TO AVOID DELAYS IN PERMITTING PLEASE DOUBLE | | | CHECK PLANS BEFORE RE-SUBMITTING. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-07-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-19 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-19 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2014-07-19 12:15:04 | 2010 FBC / 2008 NEC | | | | | | DENIED BY ELECTRICAL | | | | | | 1) THE LOAD CALCULATIONS FOR UNIT B ON SHEET E3.0 | | | CONTAINS A NUMBER OF MISTAKES. PLEASE REVIEW AND MAKE | | | CORRECTIONS. NEC 220 | | | | | | 2) ON SHEET E3.0 A #8 WIRE IS SPECIFIED FOR THE 10 KW | | | HEAT STRIP WITH A 2 POLE / 60 AMP BREAKER IN THE PANEL | | | SCHEDULE FOR UNIT A. A #6 WIRE IS REQUIRED FOR THIS | | | APPLICATION. PLEASE CORRECT. NEC TABLE 316.16. | | | | | | 3) PER THE MECHANICAL EQUIPMENT SCHEDULE UNITS B, C AND | | | D HAVE 8 KW HEAT STRIPS WITH MAXIMUM 45 AMP | | | OVER-CURRENT PROTECTION AND UNITS A AND F HAVE 10 KW | | | HEAT STRIPS WITH MAXIMUM 60 AMP OVER-CURRENT | | | PROTECTION. PLEASE REVIEW. CITY AMENDMENTS 107.2.1 | | | | | | 4) ON SHEET E1.0 THE LOCATION OF THE ELECTRICAL PANEL | | | AND THE WATER HEATER IN THE GARAGE OF UNIT D WILL NEED | | | TO BE COORDINATED SO THAT THE DEDICATED WORKING SPACE | | | IN FRONT OF THE ELECTRICAL PANEL REQUIRED BY NEC 110.26 | | | IS PROVIDED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-08-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-07 |
Time |
17:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-05 |
Time |
17:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2014-07-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-24 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2014-07-24 16:44:58 | SENT TO R. MCDOUGAL. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2014-07-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-07-15 |
Time |
18:21 |
Sent To |
|
|
| Notes |
| 2014-07-21 14:44:30 | R25 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 2014-07-15 18:22:53 | R19 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-07-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-19 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-19 |
Time |
08:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-07-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-19 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-19 |
Time |
08:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-07-23 |
|
|
Cont ID |
|
| Sent By |
avann |
Date |
2014-07-23 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2014-07-23 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2014-07-17 15:02:44 | 7/17/14 |
|
|