| 2014-09-03 12:02:12 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW |
| | COMMENTS. |
| | CODE: 2010 FBC. |
| | |
| | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| | COUNTY BUILDING (2300 N. JOG RD.) TO VERIFY IF IMPACT |
| | FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY |
| | OF THE PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE |
| | COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND |
| | DEVELOPMENT CODE. |
| | |
| | 2- CLARIFY VICTOR G VAZQUEZ TYPE OF LICENSE. THE |
| | LICENSE NUMBER 2003-18097 IS NOT REGISTERED WITH THE |
| | FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL |
| | REGULATION. DESIGN PROFESSIONALS ARE REQUIRED TO HAVE |
| | LICENSE PER CHAPTER 471 OR CHAPTER 481 FLORIDA STATUTE. |
| | |
| | 3- SHEET SP-1: |
| | A) REVISE ROOF DESIGN LOADS. COORDINATE WITH ROOF TRUSS |
| | DESIGN LOAD ON SHEET A-4 AND GENERAL NOTES ON SHEET G. |
| | N. . SEC. 107.2.1 CITY AMENDMENTS TO FBC. |
| | B) COMPONENTS AND CLADDING DESIGN PRESSURES DON'T |
| | CORRESPOND TO EXPOSURE "C" ACCORDING TO THE |
| | WINDOWS/DOORS SIZE, LOCATION (INTERIOR OR END) AND |
| | HEIGHT (INCLUDING SECOND FLOOR). REVISE AS REQUIRED AND |
| | COORDINATE WITH DESIGN PRESSURES SHOWN ON SHEET A-3. |
| | SEC. R301 OF 2010 FBC-RESIDENTIAL. |
| | |
| | 4- SHEET A-1: |
| | A) SPECIFY FOOTING FOR 4" X 4" WOOD COLUMN SHOWN ON THE |
| | FOUNDATION PLAN BY THE STAIRWAY TO SECOND FLOOR. ALSO, |
| | SPECIFY CONNECTOR AT TOP AND BOTTOM OR COLUMN. SEC. |
| | R301 OF 2010 FBC-RESIDENTIAL. |
| | ***NOTE: CLARIFY SIZE OF COLUMN. 4'X4" OR 4"X4"? |
| | |
| | B) PROVIDE COMPLETE WALL SECTION FOR SECOND FLOOR EAST |
| | WALL. THIS WALL IS NOT RESTING ON A CONCRETE BEAM AS |
| | SHOWN ON SECTION A-2 ON SHEET GD2. THIS WALL IS RESTING |
| | ON WOOD FLOOR TRUSSES. REVISE AS REQUIRED AND SPECIFY |
| | ALL FRAMING MEMBERS AND CONNECTORS. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | C) PROVIDE WALL SECTION SHOWING SECOND FLOOR SOUTH WALL |
| | RESTING ON FLOOR TRUSSES AS SHOWN ON SECOND FLOOR |
| | FRAMING PLAN. SPECIFY ALL FRAMING MEMBERS AND |
| | CONNECTORS. SEC. 107.2.1 CITY AMENDMENTS TO FBC. |
| | |
| | |
| | 5- SHEET A-2: |
| | A) SECOND FLOOR BEDROOM #2 WINDOW DOESN'T COMPLY WITH |
| | THE EGRESS REQUIREMENTS OF R310. REVISE SIZE AS |
| | REQUIRED. |
| | B) BATHROOM FOR BEDROOM #1 DOESN'T COMPLY WITH THE |
| | FIXTURES CLEARANCES REQUIRED BY SEC. R307.1 OF 2010 |
| | FBC-RESIDENTIAL. REVISE AS REQUIRED. |
| | C) NEED TO PROVIDE ONE BATHROOM WITH A DOOR THAT |
| | PROVIDES 29" MIN. CLEAR OPENING AS REQUIRED BY SEC. |
| | R320 OF 2010 FBC-RESIDENTIAL. |
| | D) REVISE HANDRAIL DETAIL AND FLOOR PLAN. NEED TO |
| | PROVIDE RAILING ON BOTH SIDES OF THE STAIRS WHERE THERE |
| | IS NO WALL. SEC. R312 OF 2010 FBC-RESIDENTIAL. |
| | |
| | 6- SHEET A-4: |
| | A) REVISE ATTIC ACCESS DETAIL. SEE SEC. R807 FOR |
| | REQUIRED MINIMUM DIMENSIONS. |
| | B) REVISE CONNECTOR SCHEDULE. CONNECTORS "C" AND "D" |
| | ARE MASONRY CONNECTORS. SECOND FLOOR IS WOOD FRAMING. |
| | NEED TO SPECIFY CORRECT CONNECTOR. AND, REVISE |
| | SPECIFICATIONS IN ALL DETAILS AND WALL SECTIONS |
| | ACCORDINGLY. SEC. 107.2.1 CITY AMENDMENTS TO FBC. |
| | C) SPECIFY SECOND FLOOR TRUSS DESIGN LOADS AS REQUIRED |
| | BY TABLE R301.5. |
| | D) SECOND FLOOR FRAMING PLAN. CLEARLY SPECIFY GIRDER BY |
| | THE STAIRWAY OPENING AND GIRDER HOLDING FLOOR TRUSSES |
| | BY THE BATH, CLOSET AND UTILITY ROOM AREA. SEC. 107.1 |
| | CITY AMENDMENTS. |
| | E) SPECIFY THE CONNECTORS AT THE ENDS OF EACH GIRDER |
| | SPECIFIED ABOVE. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 7- SHEET GD-1: |
| | A) SPECIFY HOW LONG ARE THE 5/8" ANCHOR BOLTS SPECIFIED |
| | ON THE GABLE END DETAILS. SEC. 107.2.1 CITY AMENDMENTS |
| | . |
| | B) SPECIFY HOW LONG ARE THE 5/8" ANCHOR BOLTS SPECIFIED |
| | ON THE GARAGE DOOR STRUCTURAL BUCK DETAIL. SEC. 107.2.1 |
| | CITY AMENDMENTS TO FBC. |
| | |
| | 8- WALL SECTIONS CALL FOR ASPHALT SHINGLES OR SPANISH |
| | TILE. ENGINEER TO PROVIDE SPANISH TILE FASTENING |
| | SPECIFICATIONS. SEC. 107.2.1.2 CITY AMENDMENTS. |
| | ***NOTE: THERE ARE ALSO SPECIFICATIONS TO USE "SELF |
| | ADHESIVE POLYMER FILM" UNDERLAYMENT. TAKE INTO |
| | CONSIDERATION THAT THIS PRODUCT IS LIMITED FOR ROOFING |
| | SYSTEMS THAT ARE MECHANICALLY ATTACHED. THEREFORE, ROOF |
| | TILE WITH FOAM ADHESIVE IS NOT ALLOWED. COORDINATE |
| | INFORMATION AS REQUIRED TO CONFORM WITH UNDERLAYMENT |
| | LIMITATIONS OF USE. |
| | |
| | 9- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) PRECAST LINTELS AS SPECIFIED ON PLANS AND DETAILS. |
| | B) SINGLE HUNG WINDOWS. |
| | C) WINDOW MULLIONS. |
| | D) ENTRY DOOR AS SPECIFIED ON PLANS. |
| | E) GARAGE SIDE DOOR AS SPECIFIED ON PLANS. |
| | F) DINING ROOM SWING DOOR AS SPECIFIED ON PLANS. |
| | G) GARAGE OVERHEAD DOOR. |
| | H) ASPHALT SHINGLES OR SPANISH TILE. (NOTE: COORDINATE |
| | WITH ITEM # 8 ABOVE). |
| | I) ROOFING SELF ADHESIVE POLYMER FILM AS SPECIFIED ON |
| | PLANS (NOTE: COORDINATE WITH ITEM #8 ABOVE). |
| | J) SLIDING GLASS DOORS. |
| | K) ALL SIMPSON STRUCTURAL COMPONENTS SPECIFIED ON ALL |
| | PLANS, DETAILS, SECTIONS AND SPECIFICATION. (NOTE: |
| | PROVIDE ONLY THE PRODUCT APPROVAL COVER PAGE AND PAGE |
| | SHOWING THE SPECIFIED CONNECTOR OR CLEARLY SPECIFY THE |
| | FLORIDA PRODUCT APPROVAL OR NOA NUMBER NEXT TO ALL THE |
| | SPECIFIED CONNECTORS ON PLANS AND DETAILS/SECTIONS). |
| | L) HURRICANE SHUTTERS IF WINDOWS AND DOORS WITH GLAZING |
| | DON'T HAVE IMPACT GLASS. (NOTE: NEED A COMPLETE |
| | SHUTTERS INSTALLATION SCHEDULE ALSO). |
| | |
| | |
| | 10-ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS. SEC. |
| | 107.3.4.1 OF CITY AMENDMENTS. |
| | |
| | 11- PROVIDE SITE DRAINAGE PLAN. SEC. R401.3 OF 2010 |
| | FBC-RESIDENTIAL. |
| | |
| | 12- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, |
| | CONTRACTOR'S OVERHEAD AND PROFIT AND THE DESIGN |
| | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY |
| | AMENDMENTS TO FBC. VALUATION WAS UPDATED TO $238,035. |
| | THE PERMIT FEE BALANCE IS $4,766.93. |
| | |
| | 13- PROVIDE SOIL TEST REPORT (2 COPIES WITH ORIGINAL |
| | SEAL AND SIGNATURE). SEC. R401.4 OF 2010 |
| | FBC-RESIDENTIAL. |
| | |
| | 14- PROVIDE SPECIFICATIONS FOR FIREBLOCKING BY THE |
| | STAIRS AS REQUIRED BY SEC. R302.11 OF 2010 |
| | FBC-RESIDENTIAL. |
| | |
| | 15- PROVIDE SPECIFICATIONS FOR FIRE RATING GARAGE DOOR |
| | LEADING TO THE KITCHEN AREA SHOWING COMPLIANCE WITH |
| | SEC. R302.5.1 OF 2010 FBC-RESIDENTIAL. |
| | |
| | 16- REVISE ALL ROOF SHEATHING SPECIFICATIONS SHOWN ON |
| | PLANS, DETAILS AND SPECIFICATIONS. ALL NAILS NEED TO BE |
| | RING SHANK NAILS AS REQUIRED BY SEC. R803.2.3.1 |
| | |
| | 17- SPECIFY ON PLANS CARBON MONOXIDE ALARMS AS REQUIRED |
| | BY SEC. R315 OF 2010 FBC-RESIDENTIAL. |
| | |
| | 18- MINIMUM STUCCO THICKNESS IS 7/8" IN WOOD FRAMED |
| | WALL. TABLE R702.1(1). REVISE ALL WALL SECTIONS AN |
| | DETAILS AS REQUIRED. |
| | |
| | 19- SPECIFY TWO LAYERS OF APPROVED WATER RESISTANT |
| | BARRIER ON WOOD FRAMED WALLS AS REQUIRED BY SEC. |
| | R703.6.3 OF 2010 FBC-RESIDENTIAL. REVISE ALL WALL |
| | SECTIONS AND DETAILS AS REQUIRED. |
| | |
| | 20- NEED SURVEYS WITH SURVEYOR'S ORIGINAL SEAL AND |
| | SIGNATURE AS REQUIRED BY CHAPTER 472 FLORIDA STATUTE. |
| | |
| | 21- REVISE ENERGY CALCULATIONS. SEC. 103.2.1.1.2 OF |
| | 2010 FBC-ENERGY CONSERVATION: |
| | A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, |
| | INCLUDING OWNER'S NAME, BUILDER'S NAME, PERMIT OFFICE |
| | AND JURISDICTION. |
| | B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. SEC. |
| | 103.2.3.2 OF 2010 FBC-ENERGY CONSERVATION. |
| | C) PAGE 2 OF 6. REVISE NUMBER OF OCCUPANTS. THERE IS |
| | MORE THAN 1 PERSON IN A 3 BEDROOM HOUSE. |
| | D) REVISE TYPE OF DOORS SPECIFIED ON PAGE 3 OF 6. SEE |
| | PLANS AND PRODUCT APPROVALS SUBMITTED. ALSO, DOOR WITH |
| | GLAZING ARE CONSIDERED IN THE WINDOWS AREA. SEE SEC. |
| | 405.5.3 OF 2010 FBC-ENERGY CONSERVATION. |
| | E) REVISE WINDOWS OVERHANG SEPARATION ON PAGE 3 OF 6. |
| | SEE PLANS AND REVISE AS REQUIRED. |
| | |
| | 22- PROVIDE MANUFACTURER'S SPECIFICATIONS FOR WINDOWS |
| | AND DOORS SHGC FACTOR SPECIFIED IN ITEM # 7 OF THE |
| | ENERGY CALCULATIONS SUBMITTED. SEC. 103.2.2 OF 2010 |
| | FBC-ENERGY CONSERVATION. |
| | |
| | ***PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | *** PLEASE REPLACE ANY REVISED SHEET TO EXPEDITE THE |
| | REVIEW PROCESS. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | (561)805-6712 |
| | [email protected] |