Plan Review Details - Permit 14070408
| Plan Review Stops For Permit 14070408 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-08-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-08-01 |
Time |
18:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-08-01 |
Time |
18:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-08-12 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-08-12 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-08-12 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-07-30 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-30 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-30 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2014-07-30 10:28:41 | DATE: 7/29/2014 | | | PROJECT: 1801 PALM BEACH LAKES BOULOVARD. PBLOM PILON | | | SIGN | | | PERMIT#: 14070408 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) ELECTRICAL PLANS ARE REQUIRED TO OUTLINE THE FULL | | | EXTENT OF THE ELECTRICAL SCOPE. THE PLANS ARE REQUIRED | | | TO INDICATE COMPLIANCE WITH NEC 300 FOR WIRING | | | MEATHODS, NEC 600.6 FOR REQUIRED DISCONNECT AND | | | COMPLIANCE WITH THE FBC-ENERGY CHAPTER 5 SECTION 505.2 | | | FOR EXTERIOR LIGHTING CONTROLS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: HTTP://WPB.ORG/DEVELOPMENT | | | /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM | | | ITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASAE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARETIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-08-12 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-08-12 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-08-05 |
Time |
16:51 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-08-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-08-01 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-07-11 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2014-07-11 15:35:55 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-07-23 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-07-23 |
Time |
14:47 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2014-07-23 |
Time |
14:47 |
Sent To |
E |
|
| Notes |
| 2014-07-23 14:48:00 | NO INCREASE IN SIZE | | | | | | 688.17 SQ. FT. PER FACE |
|
|
|