| Plan Review Stops For Permit 14070238 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-09-05 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-05 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-05 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-08-25 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-08-25 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-08-25 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2014-08-25 11:56:31 | 2ND REVIEW: FBC 2010 | | | | | | THE CONVEYOR SYSTEM DESIGN DOCUMENTS ARE NOT SIGNED AND | | | SEALED. | | | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, SHALL BE SUBMITTED IN TWO OR | | | MORE SETS WITH EACH PERMIT APPLICATION. THE | | | CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A | | | REGISTERED DESIGN PROFESSIONAL WHERE REQUIRED BY | | | CHAPTER 471, FLORIDA STATUTES& 61G15 FLORIDA | | | ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA STATUTES& | | | 61G1 FLORIDA ADMINISTRATIVE CODE. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-07-14 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-07-14 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2014-07-14 09:24:33 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. THE DOCUMENTS SUBMITTED APPEAR TO BE SHOP DRAWINGS | | | FOR CONSTRUTION/INSTALLATION. MOST SHEETS HAVE ALL | | | INFORMATION GREYED OUT, MAKING THEM DIFFICULT TO READ. | | | HOWEVER, THIS INFORMATION CAN BE USED AS SUPPLEMENTAL | | | INFORMATION. | | | | | | PLEASE SEE CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER ONE, SECTION 107.3.5 | | | WHICH GIVES MINIMUM PLAN REVIEW CRITERIA. PLEASE | | | INCLUDE ALL REQUIRED INFORMATION LISTED AS APPLICABLE | | | INCLUDING: | | | | | | 107.2.3, MEANS OF EGRESS. PROVIDE A LIFE SAFETY PLAN | | | WHICH SHOWS HOW THE PROPOSED IMPROVEMENT WILL AFFECT | | | EXITING. SEE FBC CHAPTER 10 INCLUDING FBC 1005 (EGRESS | | | WIDTH), FBC 1016 (EXIT ACCESS TRAVEL DISTANCE), ANY | | | OTHER INFORMATION TO SHOW CODE COMPLIANCE. | | | | | | 107.3.5.1.1(2) OCCUPANCY GROUP, (3) TYPE OF | | | CONSTRUCTION, (6) LIFE SAFETY SYSTEMS, (7) OCCUPANT | | | LOAD AND EGRESS INFORMATION, (8) STRUCTURAL | | | REQUIREMENTS, (9) MATERIALS PRPOPOSED, (10) | | | ACCESSIBILITY INFORMAITON, (11) INTERIOR REQUIREMENTS | | | AS APPLICABLE. | | | | | | 2. LIFE SAFETY PLAN TO BE PREPARED BY A DESIGN | | | PROFESSIONAL, MOST LIKELY AN ARCHITECT, FS 481. | | | | | | 3. NO STRUCTURAL INFORMATION WAS PROVIDED. AN | | | ATTACHMENT DETAIL IS TO BE PROVIDED, FBC 1601. | | | | | | 4. AS THE CONVEYOR BELT APPEARS TO BE ELEVATED, PROVIDE | | | A DETAIL SHOWNING COMPLIANCE WITH FBC 2010 ACCESSIBLITY | | | 307.4. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-08-26 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-08-26 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-08-26 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-07-21 |
|
|
Cont ID |
|
| Sent By |
swierzko |
Date |
2014-07-21 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
swierzko |
Date |
2014-07-21 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2014-07-21 16:25:24 | | | | *THE COSTRUCTION DOCUMENTS SUBMITTED APPEAR TO BE | | | LAY-OUT SHOP DRAWINGS AND LACK INFORMATION REQUIRED PER | | | 2010 FBC 107.2.1. | | | *THE DRAWINGS DO NOT MEET MINIMUM ELECTRICAL PLAN | | | REVIEW REQUIREMENTS PER 2010 FBC 107.3.5 | | | *PLANS SHALL INCLUDE WIRING METHODS & MATERIALS, BRANCH | | | CIRCUITS, OVERCURRENT PROTECTION, GROUNDING LOAD | | | CALCULATIONS AND AN | | | ELECTRICAL RISER DIAGRAM CONFORMING TO THE 2008 | | | NATIONAL ELECTRICAL CODE. | | | | | | REVIEWED BY K SWIERZKO (561) 805-6700 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-08-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-08-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-08-05 |
Time |
12:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-07-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-07-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-07-15 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2014-07-15 14:32:58 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS. | | | | | | THE PLAN COLOR LINES WERE VERY LIGHT AND UNREADABLE. | | | DARKER LINE ARE REQUIRED. | | | | | | THE PLAN HAS NO FLOW OR DIRECTION TO THE SHEET | | | DRAWINGS. THE RELATION OF EACH SHEET TO THE OVERALL | | | PROPOSED CONSTRUCTION IS NOT INDICATED. | | | | | | THERE ARE NO SYMBOL TABLES IDENTIFING ANY OF THE | | | INDICATING LINES. | | | | | | HIGHLIGHTED AREAS OF GREATER DETAIL ARE NEEDED FOR | | | GROUNDING/BONDING LOCATIONS. | | | | | | THERE IS NO LIFE SAFETY PLAN THAT INDICATES THE IMPACT | | | OF THE PROPOSED CONSTRUCTION ON EGRESS/EXITING ROUTES. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-09-05 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-05 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-05 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-08-26 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-08-26 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-08-04 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2014-08-04 14:17:50 | ROUTE TO C04 WITH DENIED PACKAGE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-07-31 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-07-31 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-07-08 |
Time |
08:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2014-09-05 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-05 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-05 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2014-08-18 |
|
|
Cont ID |
|
| Sent By |
jdariton |
Date |
2014-08-18 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
jdariton |
Date |
2014-08-18 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2014-08-18 12:02:05 | 8/18/14 | | | MUST SUBMIT 2 SETS OF PLANS. | | | REVIEWED BY JOHN ARITON. | | | FOR FURTHER ASSISTANCE PLEASE CALL HAROLD MOSER AT | | | 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-31 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-07-31 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-07-31 |
Time |
18:09 |
Sent To |
|
|
| Notes |
| 2014-07-31 18:13:07 | PLAN DENIED | | | | | | 1) CAN NOT READ PLANS REFER TO SECTION 107.2.1.4 | | | QUALITY OF BUILDING PLANS. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|