Plan Review Details - Permit 14070003
Plan Review Stops For Permit 14070003
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-07-02 Cont ID  
Sent By dhayes Date 2014-07-02 Time 13:38 Rev Time 0.00
Received By dhayes Date 2014-07-02 Time 13:38 Sent To  
Notes
2014-07-02 13:48:51DATE: 7/2/2014
 PROJECT: REVISION TO ATM REPLACEMENT.
 PERMIT#: 14070003
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC
 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
  
 1ST ELECTRICAL PLAN REVIEW
 ACTION :PROVISO
  
 EACH OPERATOR, OR OTHER PERSON RESPONSIBLE FOR AN
 AUTOMATED TELLER MACHINE PURSUANT TO SECTIONS 655.960
 THROUGH 655.965, SHALL PROVIDE LIGHTING DURING THE
 HOURS OF DARKNESS WITH RESPECT TO AN OPEN AND OPERATING
 AUTOMATED TELLER MACHINE AND ANY DEFINED PARKING AREA,
 ACCESS AREA AND THE EXTERIOR OF AN ENCLOSED AUTOMATED
 TELLER MACHINE INSTALLATION, AS FOLLOWS:
  
 1) THERE SHALL BE A MINIMUM OF 10 FOOT CANDLE (108 LUX)
 POWER AT THE FACE OF THE AUTOMATED TELLER MACHINE AND
 EXTENDING IN AN UNOBSTRUCTED DIRECTION OUTWARD 5 FEET.
  
 2) THERE SHALL BE A MINIMUM OF 2 FOOT CANDLE (21.5 LUX)
 POWER WITHIN 50 FEET (15.25 M) IN ALL UNOBSTRUCTED
 DIRECTIONS FROM THE FACE OF THE AUTOMATED TELLER
 MACHINE. IF THE AUTOMATED TELLER MACHINE IS LOCATED
 WITHIN 10 FEET (3 M) OF THE CORNER OF THE BUILDING AND
 THE AUTOMATED TELLER MACHINE IS GENERALLY ACCESSIBLE
 FROM THE ADJACENT SIDE, THERE SHALL BE A MINIMUM OF 2
 FOOT CANDLE (21.5 LUX) POWER ALONG THE FIRST 40
 UNOBSTRUCTED FEET (12 M) OF THE ADJACENT SIDE OF THE
 BUILDING.
  
 3) THERE SHALL BE A MINIMUM OF 2 FOOT CANDLE (12.5 LUX)
 POWER IN THAT PORTION OF THE DEFINED PARKING AREA
 WITHIN 60 FEET (18 M) OF THE AUTOMATED TELLER MACHINE.
  
 4) THE OPERATOR SHALL PROVIDE REFLECTIVE MIRRORS OR
 SURFACES AT EACH AUTOMATED TELLER MACHINE WHICH PROVIDE
 THE CUSTOMER WITH A REAR VIEW WHILE THE CUSTOMER IS
 ENGAGED IN USING THE AUTOMATED TELLER MACHINE
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-07-02 Cont ID  
Sent By dhayes Date 2014-07-02 Time 13:49 Rev Time 0.00
Received By dhayes Date 2014-07-01 Time 17:54 Sent To  
Notes
2014-07-01 17:54:43SENT TO D HAYES


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved