Plan Review Details - Permit 14061309
Plan Review Stops For Permit 14061309
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-08-25 Cont ID  
Sent By jgomez Date 2014-08-25 Time 13:58 Rev Time 0.00
Received By jgomez Date 2014-08-25 Time 13:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-07-23 Cont ID  
Sent By jgomez Date 2014-07-23 Time 14:05 Rev Time 0.00
Received By jgomez Date 2014-07-23 Time 13:57 Sent To  
Notes
2014-07-23 15:14:07RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- ENGINEER TO PROVIDE COMPLETE GABLE END DETAIL AND
 SPECIFICATIONS. SEC. 107.2.1.3 CITY AMENDMENTS TO FBC.
 A) SPECIFY ALL TRUSS FASTENERS.
 B) SPECIFY TRUSS BRACING.
 C) PROVIDE COMPLETE SPECIFICATIONS FOR PORCH CEILING
 DIAPHRAGM. AND WHERE IS THE STUCCO ATTACHED TO?.
 PLYWOOD?
  
 2- ENGINEER TO SPECIFY TWO LAYERS OF OF APPROVED WATER
 RESISTANT BARRIER ON AREAS TO RECEIVE STUCCO AS
 REQUIRED BY SEC. R703.6.3 OF 2010 FBC-RESIDENTIAL.
  
 3- ENGINEER TO SPECIFY WALL FINISH MATERIAL ON GABLE
 END. SEC. R701.1 OF 2010 FBC-RESIDENTIAL.
  
 4- ENGINEER TO REVISE DESIGN PARAMETERS INFORMATION ON
 SHEET 1.2.
 A) SPECIFY THE ULTIMATE AND NOMINAL WIND SPEEDS. SEC.
 R301.2.1.1 OF 2010 FBC-RESIDENTIAL.
  
 B) IF DESIGNED AS "OPENED", THEN PROVIDE CORRECT
 PRESSURES COEFFICIENT. SEC. R301.2.1.1(3) OF 2010
 FBC-RESIDENTIAL.
  
 C) PROVIDE CORRECT LIVE AND DEAD LOADS. SEC.
 R301.2.1.1(3). OF 2010 FBC-RESIDENTIAL.
  
 5- ENGINEER TO REVISE STRUCTURAL NOTE #2. COORDINATE
 WITH ITEM #4 ABOVE. SEC. R301.2.1.1 OF 2010
 FBC-RESIDENTIAL.
  
 6- ENGINEER TO SPECIFY VENTILATION AS REQUIRED BY SEC.
 R806 OF 2010 FBC-RESIDENTIAL.
  
 7- ENGINEER TO REVISE THE COMPONENT AND CLADDING
 PRESSURE ZONES ON SHEET 2.2.
 A) REVISE FASTENER SPACING TO COMPLY WITH SEC.
 R803.2.3.1 INCLUDING ROOF ZONE #3.
  
 B) PROVIDE ROOF SHEATHING NAILING ZONES PLAN FOR GABLE
 END. SEE FIGURE R803.2.3.1 OF 2010 FBC-RESIDENTIAL.
  
 8- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR ALL THE SIMPSON STRUCTURAL CONNECTORS
 SPECIFIED ON ALL PLANS AND DETAILS. ***NOTE: PROVIDE
 ONLY THE PRODUCT APPROVAL (FLORIDA OR NOA) COVE PAGE
 AND PAGE SHOWING THE SPECIFIED CONNECTOR.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-07-24 Cont ID  
Sent By rmcdouga Date 2014-07-24 Time 09:52 Rev Time 0.00
Received By rmcdouga Date 2014-07-24 Time 09:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2014-09-17 Cont ID  
Sent By dkittred Date 2014-09-17 Time 14:42 Rev Time 0.00
Received By dkittred Date 2014-09-15 Time 15:54 Sent To  
Notes
2014-09-15 15:55:02RE-SUBMITTAL SENT TO ZONING SHELF FOR DANIELLE'S
 REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-09-04 Cont ID  
Sent By dkittred Date 2014-09-04 Time 08:29 Rev Time 0.00
Received By dkittred Date 2014-08-28 Time 11:11 Sent To  
Notes
2014-08-29 11:29:27SENT TO ZONING. JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-08-25 Cont ID  
Sent By jgomez Date 2014-08-25 Time 15:02 Rev Time 0.00
Received By jgomez Date 2014-08-15 Time 16:30 Sent To  
Notes
2014-08-15 16:31:50RE-SUBMITTAL SENT TO ZONING SHELF FOR DANIELLE'S
 REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-07-24 Cont ID  
Sent By rmcdouga Date 2014-07-24 Time 09:53 Rev Time 0.00
Received By rmcdouga Date 2014-06-30 Time 17:17 Sent To  
Notes
2014-06-30 17:18:08R08

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2014-08-25 Cont ID  
Sent By jgomez Date 2014-08-25 Time 15:07 Rev Time 0.00
Received By jgomez Date 2014-08-25 Time 15:07 Sent To  
Notes
2014-08-25 15:09:50SHINGLES FLORIDA PRODUCT APPROVAL FL9792-R4.

Review Stop Z ZONING
Rev No 4 Status P Date 2014-09-17 Cont ID  
Sent By dkittred Date 2014-09-17 Time 12:53 Rev Time 0.00
Received By dkittred Date 2014-09-16 Time 12:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2014-09-04 Cont ID  
Sent By dkittred Date 2014-09-04 Time 08:28 Rev Time 0.00
Received By dkittred Date 2014-09-03 Time 11:11 Sent To  
Notes
2014-09-04 08:28:28PLANNING AND ZONING COMMENTS: ***FAILED***
  
 9/4/14
  
 COPY OF SURVEY WAS PROVIDED IN CURRENT SUBMITTAL,
 HOWEVER, THE FOLLOWING PLANNING AND ZONING COMMENT FROM
 7/2/14 STILL HAS NOT BEEN ADDRESED:
  
 1. TWO (2) COPIES OF A SITE PLAN SHOWING DIMENSIONED
 SETBACKS OF THE NEW PORCH ADDITION NEEDS TO BE
 SUBMITTED. REQUIRED MINIMUM FRONT SETBACK IS 25 FEET
 (MEASUREMENT FROM PROPERTY LINE TO PORCH COLUMNS) [ZLDR
 SEC. 94-72(A)(2)]. ROOF STRUCTURE IS PERMITTED TO
 OVERHANG UP TO 3 FEET INTO A REQUIRED SETBACK [ZLDR
 SEC. 94-305(B)(2)].
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2014-08-18 Cont ID  
Sent By dkittred Date 2014-08-18 Time 17:32 Rev Time 0.00
Received By dkittred Date 2014-08-18 Time 15:58 Sent To  
Notes
2014-08-19 08:22:008/19/14 - SENT TO JG. DK
  
2014-08-18 17:32:04PLANNING AND ZONING COMMENTS: ***FAILED***
  
 8/18/14
  
 PLANNING AND ZONING COMMENTS FROM 7/2/14 WERE NOT
 ADDRESED. A COPY OF PREVIOUS COMMENTS ARE LISTED BELOW:
  
 1. CURRENT SURVEY OF THE PROPERTY WAS NOT INCLUDED.
 PLEASE PROVIDE TWO (2) COPIES.
  
 2. TWO (2) COPIES OF A SITE PLAN SHOWING DIMENSIONED
 SETBACKS OF THE NEW PORCH ADDITION NEEDS TO BE
 SUBMITTED. REQUIRED MINIMUM FRONT SETBACK IS 25 FEET
 (MEASUREMENT FROM PROPERTY LINE TO PORCH COLUMNS) [ZLDR
 SEC. 94-72(A)(2)]. ROOF STRUCTURE IS PERMITTED TO
 OVERHANG UP TO 3 FEET INTO A REQUIRED SETBACK [ZLDR
 SEC. 94-305(B)(2)].
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2014-07-02 Cont ID  
Sent By dkittred Date 2014-07-02 Time 08:58 Rev Time 0.00
Received By dkittred Date 2014-07-02 Time 08:03 Sent To  
Notes
2014-07-02 08:58:37PLANNING AND ZONING COMMENTS: ***FAILED***
  
 7/2/14
  
 1. CURRENT SURVEY OF THE PROPERTY WAS NOT INCLUDED.
 PLEASE PROVIDE TWO (2) COPIES.
  
 2. TWO (2) COPIES OF A SITE PLAN SHOWING DIMENSIONED
 SETBACKS OF THE NEW PORCH ADDITION NEEDS TO BE
 SUBMITTED. REQUIRED MINIMUM FRONT SETBACK IS 25 FEET
 (MEASUREMENT FROM PROPERTY LINE TO PORCH COLUMNS) [ZLDR
 SEC. 94-72(A)(2)]. ROOF STRUCTURE IS PERMITTED TO
 OVERHANG UP TO 3 FEET INTO A REQUIRED SETBACK [ZLDR
 SEC. 94-305(B)(2)].
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  
  
2014-07-01 16:43:277-1-14


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved