Plan Review Details - Permit 14061264
Plan Review Stops For Permit 14061264
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-10-12 Cont ID  
Sent By shill Date 2014-10-12 Time 09:46 Rev Time 0.00
Received By shill Date 2014-10-12 Time 09:46 Sent To  
Notes
2014-10-03 07:38:18MARKED AND LEFT BOTH COPIES OF OLD PLANS AS ONLY 3 OF
 MULTIPLE SHEETS WERE RE-SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-09-11 Cont ID  
Sent By shill Date 2014-09-11 Time 17:32 Rev Time 0.00
Received By shill Date 2014-09-11 Time 17:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-07-09 Cont ID  
Sent By shill Date 2014-07-09 Time 15:22 Rev Time 0.00
Received By shill Date 2014-07-09 Time 15:22 Sent To  
Notes
2014-07-09 15:59:53****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
  
 1. NA - THIS STRUCTURE IS NOW POST FIRM (ORIGINAL
 ELEVATION CERTIFICATE RECEIVED VIA MAIL 9/2)
  
 2. DESIGN PRESSURES ARE TOO LOW. SEE FBC 1609,
 ASCE7-10. ZONE 4, +28/-30.7 REQUIRED FOR 50-100SF,
 +28/-35.3 REQUIRED FOR ZONE 5. PLEASE REVISE WIND LOAD
 CHART ACCORDINGLY OR PROVIDE ENGINEERING WITH
 CALCULATIONS FOR PROPOSED DESIGN PRESSURES.
  
 3. BLOCKING OF EXITS (COMMERCIAL BUILDINGS) WITH
 SHUTTERS IS NOT PERMITTED IN THE BUILDING CODE AND IS
 CONSIDERED ON A CASE BY CASE BASIS. SEE THE FOLLOWING
 CODE SECTIONS:
  
 FBC 1003.6, MEANS OF EGRESS CONTINUITY. THE PATH OF
 EGRESS TRAVEL ALONG A MEANS OF EGRESS SHALL NOT BE
 INTERRUPTED BY ANY BUILDING ELEMENT OTHER THAN A MEANS
 OF EGRESS COMPONENT AS SPECIFIED IN THIS CHAPTER.
 OBSTRUCTIONS SHALL NOT BE PLACED IN THE REQUIRED WIDTH
 OF A MEANS OF EGRESS EXCEPT PROJECTIONS PERMITTED BY
 THIS CHAPTER.
  
 1008.1.4.5 SECURITY GRILLS. IN GROUPS B, F, M, R AND S,
 HORIZONTAL SLIDING OR VERTICAL SECURITY GRILLES ARE
 PERMITTED AT THE MAIN EXIT AND SHALL BE OPENABLE FROM
 THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL
 KNOWLEDGE OR EFFORT DURING PERIODS THAT THE SPACE IS
 OCCUPIED. THE GRILLES SHALL REMAIN SECURED IN THE
 FULL-OPEN POSITION DURING THE PERIOD OF OCCUPANCY BY
 THE GENERAL PUBLIC. WHERE TWO OR MORE MEANS OF EGRESS
 ARE REQUIRED, NOT MORE THAN ONE-HALF OF THE EXITS OR
 EXIT ACCESS DOORWAYS SHALL BE EQUIPPED WITH HORIZONTAL
 SLIDING OR VERTICAL SECURITY GRILLES.
  
 PROVIDE A LIFE SAFETY PLAN SO RISK CAN BE EVALUATED.
  
 3. SEE PAGE 5 OF 8 ON THE PRODUCT APPROVAL 812. A NOTE
 HAS BEEN ADDED THAT THE SCREENS WILL SHARE ANCHORS AS
 NECESSARY. ANY MOFIDICATION TO THE PRODUCT APPROVALS
 ARE TO BE DONE BY AN ENGINEER. REMOVE ANY NOTES WHICH
 MODIFY INSTALLATION INSTRUCTIONS.
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2014-10-08 Cont ID  
Sent By shill Date 2014-10-12 Time 09:46 Rev Time 0.00
Received By pleduc Date 2014-10-08 Time 09:20 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2014-09-04 Cont ID  
Sent By skennedy Date 2014-10-03 Time 07:29 Rev Time 0.00
Received By pleduc Date 2014-09-04 Time 14:19 Sent To B
Notes
2014-09-04 14:36:02THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THE PROPOSED CONFIGURATION OF THE SHUTTERS AT EACH EXIT
 DOOR/DISCHARGE OBSTRUCTS THE EXIT, REDUCES THE CAPACITY
 AND IMPEDES THE PATH OF EGRESS.
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2014-07-10 Cont ID  
Sent By pleduc Date 2014-07-10 Time   Rev Time 0.00
Received By pleduc Date 2014-07-10 Time 11:47 Sent To PC
Notes
2014-07-10 11:58:20THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE PROVIDE DETAIL OF ALL EXIT LOCATIONS AND THE
 TYPE OF PROTECTION PROVIDED AT THOSE LOCATIONS. EXITS
 SHALL NOT BE BLOCKED WHILE THE BUILDING IS OCCUPIED.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-10-12 Cont ID  
Sent By shill Date 2014-10-12 Time 09:46 Rev Time 0.00
Received By shill Date 2014-10-02 Time 07:36 Sent To FIRE
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-10-03 Cont ID  
Sent By skennedy Date 2014-09-13 Time 07:29 Rev Time 0.00
Received By skennedy Date 2014-09-02 Time 15:16 Sent To FIRE
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-07-10 Cont ID  
Sent By pleduc Date 2014-07-10 Time   Rev Time 0.00
Received By pleduc Date 2014-07-09 Time 16:25 Sent To PC
Notes
2014-07-09 16:25:42TO FIRE
  
2014-06-27 10:28:17ROUTED THE MISC 1

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2014-09-11 Cont ID  
Sent By shill Date 2014-09-11 Time 17:33 Rev Time 0.00
Received By shill Date 2014-09-11 Time 17:33 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2014-07-29 Cont ID  
Sent By shill Date 2014-07-29 Time 14:50 Rev Time 0.00
Received By shill Date 2014-07-29 Time 14:50 Sent To  
Notes
2014-07-29 14:51:09EMAIL SENT TO DAVID C. LIDBERG AND CONTRACTOR, EC DATED
 7/18/14 NEEDS CORRECTIONS:
  
 ITEM B6, FIRM INDEX DATE SHOULD BE MARCH 1, 1979
 ITEM C2E, LOWEST ELEVATION OF MACHINERY OR EQUIPMENT
 SERVICING THE BUILDING IS CURRENTLY N/A. PLEASE REVISE
 TO INCLUDE ELEVATION. DESCRIBE TYPE OF EQUIPMENT AND
 LOCATION IN COMMENTS.
  
  