Plan Review Details - Permit 14061218
| Plan Review Stops For Permit 14061218 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-08 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-08 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2014-07-08 12:19:46 | BUILDING PLAN REVIEW | | | PERMIT: 14061218 | | | ADD: 2921 N AUSTRALIAN AVE | | | CONT: TBD | | | TEL: (561)827-4920 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES.JULY 08/2014 | | | ACTION: DENIED | | | CHANGE OF OCCUPANCY TO EVENT HALL | | | | | | 1)MISSING INFORMATION REQUIRED FOR A COMMERCIAL PLAN | | | REVIEW. | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, 107.3.5 MINIMUM PLAN REVIEW CRITERIA | | | FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | 1.1. SITE REQUIREMENTS: PARKING | | | 1.2 OCCUPANCY GROUP A-2 WILL THE EVENT HALL BE USED AS | | | A DANCE HALL, BANQUET HALL OR BOTH, THERE ARE NO | | | COOKING FACILITIES? | | | PLEASE PROVIDE WHAT TYPE OF EVENTS WILL BE HELD AT THIS | | | LOCATION, THE PLANS SUBMITTED STILL LOOKS LIKE A | | | FUNERAL HOME FOR VIEWING. | | | 1.3. MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED | | | (SEE TABLE 503). | | | 1.4 FIRE SPRINKLERED OR NOT? | | | 1.5 PROVIDE THE OCCUPANT LOAD FOR EACH ROOM, DEPENDING | | | ON USE THE OCCUPANT LOAD WILL VARY, FBC-B TABLE | | | 1004.1.1. | | | 1.6 PROVIDE NEW RAMP IN THE LARGE ASSEMBLY ROOM, THERE | | | IS NO TOP LANDING NOR BOTTOM LANDING, WILL NEED TO MEET | | | ALL THE REQUIREMENTS OF SECTION 1010.7 & 1010.8 | | | HANDRAILS FBC-B, MAY NEED GAURDRAILS IF THE TOP LANDING | | | IS ABOVE 30 INCHES ABOVE GRADE | | | 1.7 EMERGENCY LIGHTING & EXITING | | | 1.8 ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE | | | FOLLOWING: | | | SITE REQUIREMENTS | | | ACCESSIBLE ROUTE | | | VERTICAL ACCESSIBILITY | | | TOILET AND BATHING FACILITIES | | | DRINKING FOUNTAINS | | | | | | 2) 2010 FL ACCESSIBILITY CODE | | | 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF | | | DISPROPORTIONALITY. | | | WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH | | | OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS | | | DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION, | | | THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE | | | EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING | | | DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE | | | ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE | | | ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE | | | FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN | | | ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST | | | ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX | | | RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE | | | DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL | | | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND | | | ALARMS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-09-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-04 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-04 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2014-09-04 12:00:56 | DATE: 9/4/2014 | | | PROJECT: CHAPEL BY THE LAKE COU TO EVENT CENTER | | | PERMIT#: 14061218 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL. WPB AMENDMENTS TO THE FBC | | | 107.2.1. THERE IS NO ELECTRICAL INFORMATION ON THE | | | SUBMITTAL TO REVIEW. SEE BELOW FOR THE MINIMUM PLAN | | | REVIEW CRITERIA FOR ELECTRICAL WORK: | | | A.) 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, SECTION 107.3.5 MINIMUM PLAN REVIEW | | | CRITERIA FOR BUILDINGS.107.3.5.1.2 ELECTRICAL | | | 1. ELECTRICAL: WIRING, SERVICES, FEEDERS AND BRANCH | | | CIRCUITS, OVERCURRENT PROTECTION, GROUNDING, WIRING | | | METHODS AND MATERIALS, GFCI'S | | | 2. EQUIPMENT | | | 3. SPECIAL OCCUPANCIES | | | 4. EMERGENCY SYSTEMS | | | 5. COMMUNICATION SYSTEMS | | | 6. LOW VOLTAGE | | | 7. LOAD CALCULATIONS | | | 8. DESIGN FLOOD ELEVATION | | | | | | 2) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. WPB AMENDMENTS | | | TO FBC 107.2.1. | | | THE PLANS SUBMITTED SHALL BE SIGNED BY THE DESIGN | | | PROFESSIONAL RESPONSIBLE FOR THE DESIGN. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-07-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-07-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-07-02 |
Time |
13:57 |
Sent To |
B |
|
| Notes |
| 2014-07-02 14:04:40 | THIS PLAN WAS REVIEWED AND TENTAIVELY APPROVED BY PETER | | | LEDUC, FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE PROPOSED USE IS A MIXED OCCUPANY USE. A FIRE | | | INSPECTION IS REQUIRED TO DETERMINE OCCUPANY LOADS AND | | | LIFE SAFETY CODE REQUIREMENTS IN THE ASSEMBLY AND | | | BUSINESS OFFICE AREAS. | | | | | | THIS USE IS TENTIVELY APPROVED BASED ON OTHER CITY | | | DEPARTMENT REVIEW AND A SUBSEQUENT FIRE INSPECTION. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-04 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-26 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2014-07-01 09:33:05 | SENT TO B4 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-08 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-08 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2014-07-08 12:27:59 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2014-07-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-07-16 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-07-16 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2014-07-16 12:54:15 | MECHANICAL NOT REQUIRED AT THIS TIME. | | | THERE IS NO CHANGE IN THE CODE FOR | | | THE TWO CLASSIFICATIONS | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-08 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-08 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2014-07-08 12:27:03 | PLUMBING PLAN REVIEW | | | PERMIT: 14061218 | | | ADD: 2921 N AUSTRALIAN AVE | | | CONT: TBD | | | TEL: (561)827-4920 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES.JULY 08/2014 | | | ACTION: DENIED | | | CHANGE OF OCCUPANCY TO EVENT HALL | | | | | | 1)MISSING INFORMATION REQUIRED FOR A COMMERCIAL PLAN | | | REVIEW. | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, 107.3.5 MINIMUM PLAN REVIEW CRITERIA | | | FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.3 PLUMBING | | | 1. PROVIDE THE OCCUPANT LOADS FROM THE BUILDING | | | OCCUPANT LOAD AND SEE WHAT THE MINIMUM FIXTURE COUNT | | | WILL BE. MINIMUM PLUMBING FACILITIES. 403.1.3.2 | | | OCCUPANCY CONTENT CALCULATION. | | | THE OCCUPANCY CONTENT OF A BUILDING, WHICH DETERMINES | | | THE NUMBER OF WATER CLOSETS REQUIRED FOR MEN, SHALL BE | | | CALCULATED USING THE SQUARE FOOTAGE PER PERSON | | | REQUIREMENTS ESTABLISHED BY THE FLORIDA BUILDING CODE, | | | BUILDING. | | | | | | 2) 2010 FBC-PLUMBING TABLE 403.1 MINIMUM NUMBER OF | | | REQUIRED PLUMBING FIXTURES 403.3 REQUIRED PUBLIC TOILET | | | FACILITIES. | | | CUSTOMERS, PATRONS AND VISITORS SHALL BE PROVIDED WITH | | | PUBLIC TOILET FACILITIES IN STRUCTURES AND TENANT | | | SPACES INTENDED FOR PUBLIC UTILIZATION. THE NUMBER OF | | | PLUMBING FIXTURES LOCATED WITHIN THE REQUIRED TOILET | | | FACILITIES SHALL BE PROVIDED IN ACCORDANCE WITH SECTION | | | 403 FOR ALL USERS. EMPLOYEES SHALL BE PROVIDED WITH | | | TOILET FACILITIES IN ALL OCCUPANCIES. EMPLOYEE TOILET | | | FACILITIES SHALL BE EITHER SEPARATE OR COMBINED | | | EMPLOYEE AND PUBLIC TOILET FACILITIES. | | | | | | 3) 2010 FL ACCESSIBILITY CODE 211.2 MINIMUM NUMBER. | | | NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. | | | ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH | | | 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH | | | 602.7. | | | | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-07-10 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2014-07-10 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2014-07-10 |
Time |
11:11 |
Sent To |
E |
|
| Notes |
| 2014-07-09 15:43:26 | 7/9/14 ZONING DENIED | | | | | | 1. USE OF BUILDING NOT PERMITTED, CLASS B IS REQUIRED. |
|
|
|