Plan Review Details - Permit 14061136
| Plan Review Stops For Permit 14061136 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-07-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-07-31 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-07-31 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-07-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-07-16 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-07-16 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2014-07-16 17:22:50 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. SEE OPENING #1. SPAN IS SHOWN AS 108" (9'). SEE | | | SHEET 10. CONCRETE SUBSTRATE ON THE TOP, CONNECTION | | | TYPE C3, ELCO ULTRACON, 9' SPAN, 62PSF, CANNOT BE USED | | | (BOX IS HATCHED). | | | | | | CONTRACTOR HAS HIGHLIGHTED THE ROW FOR 48PSF, BUT | | | DESIGN PRESSURE PROPOSED FOR THIS OPENING IS 49.4, SO | | | THE NEXT ROW (62PSF) MUST BE USED. | | | | | | 2. SEE OPENING #1, BOTTOM AND CHART ON SHEET 11. FOR | | | CONCRETE BLOCK, ULTRACON, CONNECTION TYPE C3, IS | | | HATCHED (CANNOT BE USED) FOR 62 PSF. | | | | | | 3. REVISE INSTALLATION SCHEDULE TO BE MORE SPECIFIC | | | REGARDING THE FASTENER. THERE ARE DIFFERENT DIAMETER OF | | | ELCO ULTRACON. | | | | | | CHECK ALL OPENINGS AS THE ONE GIVEN IS ONLY ONE | | | EXAMPLE. THE OTHER OPENINGS HAVE THE SAME ISSUE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-07-05 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-07-05 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2014-07-05 14:59:39 | ****CORRECTIONS**** | | | ****REVISED 7/8/14**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | | | 2. INFORMATIONAL ONLY - FS471, CONTRACTOR IS NOT TO USE | | | THE WORD "ENGINEERING" IN HIS COMPANY NAME UNLESS AN | | | ENGINEER QUALIFIES THE COMPANY. PER CONVERSATION WITH | | | CONTRACTOR'S REPRESENTATIVE, CONTRACTOR WILL RESOLVE | | | THIS ISSUE BUT THIS PERMIT WILL BE ISSUED UNDER THE | | | CURRENT NAME AFTER ITEM #1 IS ADDRESSED. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-07-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-07-31 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-07-18 |
Time |
11:26 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-07-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-07-16 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-07-11 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2014-07-11 11:23:06 | RE-SUBMITTAL SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-07-05 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-06-25 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2014-06-25 09:07:22 | MISC 1 | | | |
|
|
|