| Plan Review Stops For Permit 14060869 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-09-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-17 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-17 |
Time |
10:24 |
Sent To |
E |
|
| Notes |
| 2014-12-10 10:26:15 | THE STRUCTURE IS NOT TO BE USED AS AN ACCESSORY | | | APARTMENT. IT IS TO REMAIN AS A UTILITY OCCUPANCY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-09 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-09 |
Time |
06:38 |
Sent To |
|
|
| Notes |
| 2014-07-09 07:24:16 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | THE SCOPE OF WORK FOR THIS PERMIT IS TO ADDRESS THE | | | ILLEGAL CONVERSION OF AN EXISTING GARAGE TO AN | | | APARTMENT OR ACCESSORY STRUCTURE. | | | ACCORDING TO CITY RECORDS, THIS STRUCTURE WAS | | | ORIGINALLY CONSTRUCTED AS A DETACHED GARAGE. IT WAS | | | CONVERTED TO AN APARTMENT WITH A KITCHEN, BEDROOM AND | | | BATHROOM WITHOUT THE REQUIRED PERMITS OR INSPECTIONS. | | | UNDER THE 2010 FBC EXISTING BUILDING THIS IS CONSIDERED | | | A CHANGE OF OCCUPANCY. IN ORDER FOR THIS STRUCTURE-TO | | | BE BROUGHT INTO COMPLIANCE, IT WILL BE REQUIRED TO | | | COMPLY WITH THE 2010 FBC EXISTING BUILDING FOR A CHANGE | | | OF OCCUPANCY FROM A UTILITY TO AN R-3 OCCUPANCY. THIS | | | CHANGE IS FROM A LOWER HAZARD CATEGORY TO A HIGHER ONE. | | | THEREFORE, THE FOLLOWING ITEMS WILL NEED TO BE BROUGHT | | | INTO COMPLIANCE. THE STRUCTURE WILL BE REQUIRED TO | | | COMPLY WITH THE 2010 FBCR WINDLOAD REQUIREMENTS FOR THE | | | BUILDING ENVELOPE ( IN ADDITION TO GRAVITY LOADS), | | | PRODUCT APPROVALS FOR EXTERIOR DOORS AND WINDOWS, | | | EGRESS REQUIREMENTS, LIGHT AND VENTILATION, SMOKE AND | | | CARBON MONOXIDE ALARMS, FIRE PROTECTION REQUIREMENTS | | | (SEPARATION DISTANCE AND ALLOWABLE OPENINGS), THE | | | REQUIREMENTS OF THE 2010 FBC ENERGY CONSERVATION, THE | | | REQUIREMENTS OF THE 2010 FBCR MECHANICAL, THE | | | REQUIREMENTS OF THE 2010 FBCR PLUMBING AND THE | | | ELECTRICAL SYSTEM WILL BE REQUIRED TO COMPLY WITH THE | | | 2008 NATIONAL ELECTRICAL CODE. THE PLANS WILL NEED TO | | | SHOW HOW THE GARAGE WILL BE CONVERTED TO HABITABLE | | | SPACE IN COMPLIANCE WITH THE 2010 FBC AND 2008 NEC. THE | | | PLANS WILL NEED TO BE REVIEWED BY PALM BEACH COUNTY TO | | | DETERMINE IF ANY IMPACT FEES ARE DUE. | | | | | | 1) THIS IS NOT A LEVEL 2 ALTERATION AS INDICATED ON | | | SHEET 1 OF THE PLANS. THIS IS A CHANGE OF OCCUPANCY | | | FROM A LOWER HAZARD (U, UTILITY/GARAGE ) TO A HIGHER | | | ONE (R-3, RESIDENTIAL). FBC EXISTING BUILDING SECTION | | | 406. PLEASE CORRECT. | | | | | | 2) SHOW THAT THE EXTERIOR DOOR COMPLIES WITH FBCR 311.2 | | | FOR EGRESS. | | | | | | 3) THE ROOM WITH THE CLOSET APPEARS TO BE A BEDROOM | | | ALTHOUGH IT IS SPECIFIED AS A RECREATION ROOM ON THE | | | PLANS. THIS ROOM IS REQUIRED TO HAVE AN EMERGENCY AND | | | RESCUE OPENING. AN EXISTING OPERABLE WINDOW WITH CLEAR | | | OPENING AREA NO LESS THAN 4 SQUARE FEET AND WITH | | | MINIMUM OPENING WIDTH AND HEIGHT OF 22 INCHES AND 20 | | | INCHES RESPECTIVELY, WITH MAXIMUM SILL HEIGHT AT 44 | | | INCHES ABOVE THE FLOOR IS ALLOWED BY FBC EXISTING | | | BUILDING SECTION 912.4.1 EXCEPTION NUMBER 7. | | | | | | 4) SHOW COMPLIANCE WITH FBCR 314.3.1 FOR SMOKE ALARMS | | | AS REQUIRED FOR NEW DWELLINGS. | | | | | | 5) FBC EXISTING BUILDING SECTION 907.2 REQUIRES THE | | | STRUCTURE TO BE ANALYZED AND MADE TO COMPLY WITH THE | | | APPLICABLE WINDLOADS OF THE FLORIDA BUILDING CODE. | | | PROVIDE DOCUMENTATION TO SHOW COMPLIANCE. SUBMIT | | | STRUCTURAL DRAWINGS AND DETAILS. CITY AMENDMENTS | | | 107.2.1 | | | | | | 6) SUBMIT PRODUCT APPROVALS FOR EXTERIOR DOORS AND | | | WINDOWS AS REQUIRED BY DCA RULE 9N-3. | | | | | | 7) SHOW COMPLIANCE WITH FBCR 301.2.1.2 FOR LARGE | | | MISSILE IMPACT PROTECTION OF EXTERIOR GLAZED OPENINGS. | | | | | | 8) THE DESIGN CRITERIA ON SHEET 1 STATES THAT THIS IS A | | | PARTICALLY OPEN STRUCTURE. THE PLANS THAT WERE | | | SUBMITTED SHOW THIS IS AN ENCLOSED STRUCTURE. PLEASE | | | CORRECT. CITY AMENDMENTS 107.2.1 | | | | | | 9) PROVIDE A RESPONSE LETTER INDICATING HOW THE REVIEW | | | COMMENTS HAVE BEEN ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2014-12-10 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-10 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-10 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2014-12-10 09:40:20 | SEE ELECTRICAL PERMIT #14090886 WHICH WAS ISSUED AS A | | | STAND ALONE PERMIT SUBMITTED SEPARATLY AT A LATER DATE | | | BY NON-STOP ELECTRIC HIRED DIRECTLY BY THE OWNER NOT BY | | | MAKO CONSRTUCTION TO COMPLETE THE ELECTRICAL SERVICE, | | | SUB-PANEL AND ELECTRICAL TANKLESS WATER HEATER SCOPE OF | | | WORK. THE PERMIT WAS ISSUED. THE WORK WAS COMPLETED, | | | INSPECTED AND FINALED ON 10/09/14 SEE INSPECTION | | | RESULTS BELOW: | | | | | | PERMIT #14090886 | | | 203 1 0008-E 10/09/2014 10/09/2014 P | | | | | | THIS IS FOR THE ELECTRICAL SERVICE RISER, SUB-PANEL AND | | | CONNECTION OF THE ELECTRIC TANKLESS WATER HEATER ONLY. | | | THE SAME ELECTRICAL CONTRACTOR HAS STATED HE WILL COME | | | IN TODAY OR TOMORROW TO SUBMIT ANOTHER PERMIT | | | APPLICATION FOR THE BALANCE OF ELECTRICAL WORK ON THIS | | | PLAN. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2014-12-01 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-01 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-01 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2014-12-01 11:54:48 | DATE: 12/1/2014 | | | PROJECT: UTILITY STRUCTURE RENNOVATION | | | PERMIT#: 14060869 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 3RD ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) INDICATE SITE PLAN THE LOCATION OF THE ELECTRICAL | | | SERVICE WITH 200AMP MAIN (PANEL), THE HOUSE PANEL, AND | | | TANKLESS WATER HEATER, | | | | | | 2) PROVIDE A COMPLETE LOAD CALCULATION. LOADS FOR NEW | | | CIRCUITS OR EXTENDED CIRCUITS IN PREVIOUSLY WIRED | | | DWELLING UNITS SHALL BE CALCULATED IN ACCORDANCE WITH | | | NEC 220.12 OR 220.14, AS APPLICABLE. NEC 220.40, NEC | | | 220.16(2) | | | | | | 3) EVERY CIRCUIT AND CIRCUIT MODIFICATION IN THE PANEL | | | SCHEDULE SHALL BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, | | | EVIDENT, AND SPECIFIC PURPOSE OR USE. ADD CIRCUIT IN | | | THE SUB-PANEL TO IDENTIFY THE A/C CU. NEC 408.4, | | | | | | 4) REVISE THE RISER DIAGRAM TO INDICATE HOW THE 150AMP | | | HOUSE PANEL, THE 125AMP UTILITY RM PANEL, AND NOW THE | | | TANKLESS WATER HEATER ARE FED. | | | | | | 5) REVISE THE RISER DIAGRAM TO INDICATE THE CORRECT | | | SIZED CONDUCTORS ARE IN THE SERVICE RISER MAST AND | | | NIPPLE TO THE "MAIN"(PANEL) ARE APPROVED FOR THE TOTAL | | | CONNECTED LOAD TO BE SERVED. THE CONDUCTOR SIZES | | | CURRENTLY INDICATED ON THE RISER DIAGRAM ARE NOT | | | APPROVED FOR THE LOAD TO BE SERVED. | | | | | | 6) INDICATE THE LOCATION AND MEANS OF DISCONNECT FOR | | | THE TANKLESS WATER HEATER, A/C CU, AND AHU. NEC 422.31, | | | WPB AMENDMENTS TO FBC 107.3.2 | | | | | | 7) REVISE THE FLOOR PLAN TO INCLUDE THE CIRCUIT NUMBERS | | | TO COINCIDE WITH THE PANEL SCHEDULE. ADD THE CIRCUIT | | | FOR THE A/C, CU AND THE TANKLESSS WATER HEATER. FBC- 1 | | | 07.3.5.3 | | | | | | 8) VERIFY THE FLOOR PLAN TO INDICATE RECEPTACLE OUTLETS | | | ARE INSTALLED AT EACH KITCHEN COUNTERTOP SPACE THAT IS | | | 12" OR WIDER. RECEPTACLE OUTLETS SHALL BE INSTALLED SO | | | THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24" | | | MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT | | | SPACE. RECEPTACLES SHALL BE INSTALLED SUCH THAT NO | | | POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY | | | WALL SPACE IS MORE THAN (6 FT) FROM A RECEPTACLE | | | OUTLET. NEC 210.52(C)(1) | | | | | | 9) ALL NEW GENERAL PURPOSE OUTLETS MUST BE TAMPER | | | RESISTANT AND AFCI PROTECTED. NEC 210.12, 406.11 | | | | | | 11) A BONDING STRIP IS REQUIRED AT SERVICE GROUND. NEC | | | 250.94 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-09-18 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-18 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-18 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2014-09-18 08:03:51 | DATE: 9/18/2014 | | | PROJECT: UTILITY STRUCTURE RENNOVATION | | | PERMIT#: 14060869 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) THE TOTAL KW LOAD INDICATED AT THE UTILLITY RM SUB | | | PANEL IS 35.4KW WHICH WOULD BE THE EQUIVILANT OF | | | 147AMPS NOT 90 AMPS AS INDICATED AT THE RISER DIAGRAM, | | | THE CALCULATED LOAD OF A FEEDER OR SERVICE SHALL NOT BE | | | LESS THAN THE SUM OF THE LOADS ON THE BRANCH CIRCUITS | | | SUPPLIED, AS DETERMINED BY PART II OF THIS ARTICLE, | | | AFTER ANY APPLICABLE DEMAND FACTORS PERMITTED BY PART | | | III OR IV OR REQUIRED BY PART V HAVE BEEN APPLIED. NEC | | | 220.40 | | | PROVIDE A COMPLETE LOAD CALCULATION ON THE UTILITY | | | STRUCTURE AND ON THE WHOLE ELECTRICAL SERVICE INCLUDING | | | THE MAIN HOUSE. PROVIDE A PANEL SCHEDULE SHOWING ALL | | | LOADS BALANCED. INDICATE THE PROPOSED WIRING METHOD, | | | WIRE SIZE WITH OVER CURRENT PROTECTION FOR ALL | | | CIRCUITS. NEC 215.5, 220.12, 220.40, 230.31 | | | | | | 2) THE ELECTRICAL SERVICE RISER DIAGRAM NEEDS TO BE | | | REVISED TO INDICATE HOW THE TRANSITION IS MADE FROM THE | | | 200AMP MAIN BREAKER AT THE HOUSE TO FEED THE 150AMP | | | HOUSE PANEL AND THE 125AMP UTILITY RM PANEL. | | | | | | 3) INDICATE THE LOCATION AND MEANS OF DISCONNECT FOR | | | THE ELECTRIC WATER HEATER, AND A/C AHU. NEC 422.31, WPB | | | AMENDMENTS TO FBC 107.3.2 | | | | | | 5) A BONDING STRIP IS REQUIRED AT SERVICE GROUND. NEC | | | 250.94 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-07-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-09 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-09 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2014-07-09 14:15:51 | 2010 FBC / 2008 NEC | | | | | | DENIED BY ELECTRIC | | | | | | 1) ACCORDING TO THE ZONING REVIEW THIS LOT IS ZONED AS | | | SINGLE FAMILY AND ONLY ONE METER IS ALLOWED FOR A | | | SINGLE FAMILY DWELLING. SUBMIT AN ELECTRICAL RISER PLAN | | | THAT SHOWS COMPLIANCE WITH THE ZONING CODE AND THE 2008 | | | NEC. | | | | | | 2) THIS ACCESSORY STRUCTURE IS NOT ALLOWED TO HAVE A | | | KITCHEN PER THE ZONING REVIEW. REMOVE THE KITCHEN FROM | | | THE PLANS. | | | | | | 3) SHOW COMPLIANCE WITH NEC 210.52 FOR RECEPTACLE | | | SPACING. | | | | | | 4) SHOW COMPLIANCE WITH NEC 210.12 FOR ARC-FAULT | | | PROTECTION. | | | | | | 5) SHOW COMPLIANCE WITH NEC 406.11 FOR TAMPER-RESISTANT | | | RECEPTACLES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2014-12-10 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-10 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-10 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-12-01 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-01 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-22 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2014-11-22 09:51:39 | GAVE TO D HAYES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-18 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-18 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-11 |
Time |
07:19 |
Sent To |
|
|
| Notes |
| 2014-09-12 07:19:38 | SENT TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-07-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-09 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-19 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2014-06-23 11:24:43 | SENT TO R13 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
N |
Date |
2014-12-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-10 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-10 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2014-12-10 10:06:07 | DETACHED STRUCTURE IS TO REMAIN AS STORAGE/UTILITY. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2014-09-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-17 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-17 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2014-09-17 11:11:19 | IMPACT FEES | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED | | | WITH A COPY OF RECEIPT AS APPLICABLE. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-07-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-09 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-09 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2014-07-09 07:43:03 | THIS WAS A GARAGE THAT WAS CONVERTED TO LIVING SPACE. | | | WHEN THE PLANS HAVE BEEN APPROVED, ONE OF THE APPROVED | | | SETS IS REQUIRED TO BE SIGNED OUT AN TAKEN TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT REVIEW STAMP AND A COPY OF THE PAID RECEIPT | | | ARE REQUIRED TO BE RETURNED TO THE CITY BEFORE THE | | | BUILDING PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2014-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-22 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-22 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-09-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-17 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-17 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-08 |
Time |
18:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-08 |
Time |
18:46 |
Sent To |
|
|
| Notes |
| 2014-07-08 18:49:18 | 2010 FBC | | | | | | DENIED BY MECHANICAL | | | | | | 1) SUBMIT TWO COPIES OF EQUIPMENT SIZING CALCULATIONS | | | FOR THE HEATING AND COOLING EQUIPMENT. FBCR M1401.3 | | | | | | 2) SPECIFY THE SIZE OF ALL DUCTS, GRILL SIZES AND CFMS | | | AT EACH SUPPLY OUTLET ON THE PLANS. | | | | | | 3) RETURN AIR CAN NOT BE TAKEN FROM A CLOSET. SHOW HOW | | | THE RETURN AIR TO THE AIR HANDLER WILL BE PROVIDED. | | | FBCR M 1602.2 | | | | | | 4) SHOW COMPLIANCE WITH FBCR M 1602.4 FOR BALANCED | | | RETURN AIR. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-22 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-22 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-09-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-09-17 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-09-17 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-07-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-08 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-08 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2014-07-08 18:45:11 | 2010 FBC | | | | | | DENIED BY PLUMBING | | | | | | 1) SPECIFY THE SIZES OF ALL SANITARY AND VENT PIPING ON | | | THE PLANS. FBCR P3001.1 AND P3101.1 | | | | | | 2) THE FIXTURE OUTLET AT THE KITCHEN IS LABELED AS A | | | LAVATORY AND THE CLOTHES WASHER IS ALSO LABELED AS A | | | LAVATORY. PLEASE CORRECT. CITY AMENDMENTS 107.2.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-09-12 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-09-12 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-09-12 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2014-09-12 10:07:15 | 9/12/14 - SENT TO RM. DK |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-06-25 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-06-25 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-06-25 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2014-06-25 12:32:36 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 6/25/14 | | | | | | ZONING OF 430 NOTTINGHAM BLVD. IS MF20. BASED ON A LOT | | | SIZE OF 50' X 100', ONLY A SINGLE FAMILY RESIDENCE IS | | | PERMITTED AT THIS LOCATION. IT APPEARS THE ACCESSORY | | | STRUCTURE IS BEING CONVERTED TO AN ACCESSORY APARTMENT. | | | ACCESSORY STRUCTURE IS PERMITTED TO BE CONVERTED TO | | | HABITABLE SPACE FOR USE BY THE MAIN RESIDENCE ONLY, BUT | | | CAN NOT BE A SEPARATE ACCESSORY APARTMENT. AS A | | | RESULT... | | | | | | 1. NO KITCHEN FACILITIES, WHICH INCLUDES STOVE (OR | | | OTHER COOKING FACILITIES), FULL SIZE REFRIGERATOR, | | | AND/OR FULL SINK ARE PERMITTED IN THE RENOVATED | | | ACCESSORY STRUCTURE. PLEASE INDICATE COMPLIANCE WITH | | | THIS ITEM AS THE PLANS CURRENTLY DEPICT WHAT APPEARS TO | | | BE A KITCHEN IN THE ACCESSORY STRUCTURE, | | | | | | 2. MULTIPLE ELECTRIC METERS FOR THE PROPERTY ARE NOT | | | PERMITTED. IT APPEARS ON THE PLAN THAT THERE ARE TWO | | | ELECTRIC METERS FOR THE SUBJECT PROPERTY. ONLY ONE WILL | | | BE PERMITTED. PLEASE REVISE PLANS ACCORDINGLY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | 2014-06-25 11:48:43 | 6/25/14 |
|
|