| Plan Review Stops For Permit 14060856 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-06 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-06 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-09-16 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-09-16 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-09-16 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-08-27 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-08-27 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-08-27 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2014-08-27 12:15:07 | 14060856 | | | 1855 PALM BEACH LAKES BLVD. #B02 | | | REVISIONS | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS. | | | | | | SHEET B2 E001A | | | PANEL A AND B ARE SHOWN AS MAIN LUG ONLY. INDICATE | | | WHERE THE MAIN DISCONNECTS ARE LOCATED FOR THESE PANEL | | | BOARDS. NEC 240.21, 408.36 | | | | | | SHEET B2 E001 | | | PANEL BOARDS SHOWN DO NOT MATCH THE RISER PLAN | | | SUBMITTED. NEC 215.5 | | | | | | SHEET B2 E002 | | | ELECTRIC RISER DOES NOT SEEM TO MATCH PANEL SCHEDULES | | | SUBMITTED. NEC 215.5 | | | | | | | | | ROBERT LECKY, CBO | | | ELECTRICAL PLANS REVIEW | | | 561-373-3701 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-08-04 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-08-04 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-08-04 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2014-09-16 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-12 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-08-27 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-08-27 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-07-29 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2014-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-06 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-06 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2014-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-06 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-06 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2014-09-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-19 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-18 |
Time |
11:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-09-04 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-09-04 |
Time |
08:18 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2014-09-04 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2014-09-04 08:45:31 | PASSED W/PROVISO | | | | | | 1) THE SQUARE FOOTAGE TOTALS LISTED ON THE COVER SHEET | | | ARE NOT APPROVED AS PART OF THIE REVISION. THE | | | CORRECTED TOTAL (59,727 SQ. FT) IS APPROVED UNDER | | | REVISION NO. 14080856. | | | | | | 2) ALL THE ROOFTOP MECHANICAL EQUIPMENT NEEDS TO BE | | | SCREENED. | | | | | | 3) THE AWNINGS REQUIRE SEPARATE PERMITS, WITH PLANS, | | | AND THEY SHALL BE CENTERED OVER THEIR RESPECTIVE DOORS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-08-19 |
Time |
14:09 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2014-08-19 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2014-08-19 13:49:43 | FAILED | | | | | | PROVIDE WRITTEN RESPONSE TO COMMENTS. SEE CLOUDED AREAS | | | ON THE DIGITAL COVER SHEET. | | | | | | 1) PLEASE EXPLAIN HOW THE BUILDING AREA WENT FROM | | | 59,727 SQ. FT. ON REVISION PERMIT NO. 14060173 (ADDED | | | FIRE SEPARATIONS) TO 58,517 SQ. FT. ON THIS REVISION. | | | THE BUILDING PLANS DO NOT SHOW A SMALLER BUILDING. | | | | | | 2) WHY IS THE TOTAL BUILDING AREA OF 58,517 SQ. FT YET | | | THE OCCUPANT LOAD CALCULATION SHOWS 58,690 SQ. FT. | | | | | | 3) WHAT HAPPENED TO THE SQUARE FOOTAGE TABULATION FOR | | | THE LANDLORDS ROOMS? | | | | | | 4) PLEASE REMEMBER THAT ALL THE ROOFTOP MECHANICAL | | | EQUIPMENT NEEDS TO BE SCREENED. | | | | | | 5) THE AWNINGS REQUIRE SEPARATE PERMITS, WITH PLANS, | | | AND THEY SHALL BE CENTERED OVER THEIR RESPECTIVE DOORS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | | | | 2014-07-30 09:45:05 | 7/30/14 |
|
|