| Plan Review Stops For Permit 14060781 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-08-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-08 |
Time |
06:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-08 |
Time |
05:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-07-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-25 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-25 |
Time |
06:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-06-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-30 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-28 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2014-06-30 13:52:47 | BUILDING PLAN REVIEW | | | PERMIT: 14060781 | | | ADD: 1845 PALM BCH LAKES BLVD BLDG "C" WHOLE FOODS | | | CONT: TBD | | | TEL: (561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JUNE 30/ 2014 | | | ACTION: DENIED | | | | | | 1) SHEET CS-2 INDICATES UNDER THE CODE ANALYSIS | | | EXISTING BUILDING. NOTE THIS IS A SHELL BUILDING, NO | | | FIRST TENANCY, THE 2010 FBC-BUILDING WILL BE USED FOR | | | NEW BUILDINGS SINCE THERE HAS NEVER BEEN A C. O. | | | ISSUED. | | | | | | 2) SHEET CS-2 INDICATES A MEZZANINE AREA D-3 TO BE USED | | | SOLEY FOR REFRIGARANT / WATER HEATING, NO STORAGE. THE | | | UPPER HALF OF THE STAIRWAY IS ENCLOSED WITH A DOOR. THE | | | 2010 FBC-B 505.4 DOES ALLOW FOR ENCLOSED MEZZANINES | | | WITH AN OCCUPANT LOAD OF LESS THAN 10 WHICH THIS DOES. | | | THE ENCLOSING THE UPPER HALF OF THE STAIR DOES NOT GIVE | | | A WORK MAN IN THIS SPACE ANY NOTIFICATION OF A FIRE AND | | | SMOKE AND THE AMOUNT OF NOISE THE REFRIGARATION | | | EQUIPMENT. FOR THIS REASON WE WOULD LIKE TO SUGGEST A | | | STROBE THAT WOULD TIE INTO THE ALARM SYSTEM TO ALERT | | | ANY WORKMAN IN THIS LIMITED SPACE TO EVACUATE. THIS | | | SPACE NOW DOES NOT COMMUNICATE WITH THE REMAINDER OF | | | THE 1 ST FLOOR. THERE IS NO ACTUAL CODE SECTION TO | | | ADDRESS OUR CONCERNS, THIS CAN ONLY BE A SUGGESTION. | | | | | | 3) SHEET A2.07 IDENTIFIES THE DOORS WITHIN TTHE | | | TENANCY. DOORS 100,& 101 ARE IDENTIFIED AS EXISTING THE | | | DOOR SCHEDULE FOUND ON A702 | | | THE NOTES DO NOT PROVIDE THE TYPE OF HARDWARE, NOTES | | | INDICATE CYLINDER LOCK TO BE INSTALLED. PLEASE SHOW | | | COMPLIANCE WITH 2010 FBC-B | | | 008.1.9.3 LOCKS AND LATCHES. 2.2. A READILY VISIBLE | | | DURABLE SIGN IS POSTED ON THE EGRESS SIDE ON OR | | | ADJACENT TO THE DOOR STATING: THIS DOOR TO REMAIN | | | UNLOCKED WHEN BUILDING IS OCCUPIED. THE SIGN SHALL BE | | | IN LETTERS 1 INCH (25 MM) HIGH ON A CONTRASTING | | | BACKGROUND. | | | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-07-17 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-17 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-17 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2014-07-17 13:59:02 | DATE: 7/14/2014 | | | PROJECT: WHOLE FOODS WPB | | | PERMIT : 14060781 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) EMERGENCY LIGHTING REQUIRED FOR MEZZANINE AND | | | STAIRWAY TO MEZZANINE. | | | | | | 2) SEPARATE PERMITS AND PLANS ARE REQUIRED FOR, | | | GENERATOR, FIRE ALARM, SECURITY, NETWORK, ENERGY | | | MANAGEMENT, REFRIGERATION CONTROL, AND POINT OF SALE | | | SYSTEMS | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-07-28 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-07-28 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-07-28 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-07-02 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-07-02 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-07-02 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2014-07-02 15:11:52 | PERMIT # 14060781 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ***FAILED COMMENTS TO BE ADDRESSED IN RESUBMITAL**** | | | | | | 1) THE REFLECTED CEILING PLAN A202 SHOWS THE LOCATION | | | OF THE EXIT SIGNS, BUT DOES NOT INDICATE ANY EMERGENCY | | | LIGHTING. | | | | | | 2) PROVIDE DRAWING NOTE INDICATING THAT WHERE MUSIC | | | SYSTEMS ARE BEING INSTALLED A RELAY TO THE FIRE ALARM | | | SYSTEM MUST BE INCLUDED SO AS TO SHUT-OFF THE MUSIC | | | UPON ACTIVATION OF THE FIRE ALARM SYSTEM. | | | | | | ***COMMENTS TO BE ADDRESSED IN THE FIELD.*** | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED BY EMAIL ([email protected]) | | | ([email protected]) OR IN WRITING (FAX: 561-804-4774) AND | | | APPROVED BY THE OFFICE OF THE FIRE MARSHAL LOCATED AT | | | 500 NORTH DIXIE HIGHWAY. | | | | | | EACH FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED WITH | | | SIGNS OR STENCILING READING FIRE BARRIER-PROTECT ALL | | | OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN | | | HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE | | | SPACED NOT MORE THAN 15 FEET ON CENTER. | | | | | | PROVIDE 44 INCH WIDE STRIPING (DEMARCATION) IN | | | STOCKROOM TO ENSURE EGRESS PATH REQUIREMENTS ARE | | | MAINTAINED AT ALL TIMES. | | | | | | AN APPROVED WRITTEN EMERGENCY PLAN FOR THE EMERGENCY | | | EGRESS OF OCCUPANTS IS REQUIRED PRIOR TO OCCUPANCY. ALL | | | EMPLOYEES SHALL BE INSTRUCTED AND PERIODICALLY DRILLED | | | WITH RESPECT TO THEIR DUTIES UNDER THE PLAN. | | | | | | EMPLOYEES SHALL BE PERIODICALLY TRAINED OR INSTRUCTED | | | IN THE USE OF PORTABLE FIRE EXTINGUISHERS. | | | | | | SUB-PERMITS REQUIRED FOR ALL WORK DONE RELATED TO THE | | | FIRE ALARM AND SPRINKLER SYSTEM. | | | | | | | | | SUE ELLEN CALDERON | | | FIRE INSPECTOR & INVESTIGATOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2014-07-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-25 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-25 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2014-07-25 08:15:42 | FUEL GAS PLAN REVIEW | | | PERMIT: 14060781 | | | ADD: 1845 PALM BCH LAKES BLVD BLDG "C" WHOLE FOODS | | | CONT: TBD | | | TEL: (561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2ND REVIEW 1ST REVIEW WAS PART OF THE PLUMBING REVIEW | | | DATE: FRI. JULY 25/ 2014 | | | | | | ACTION: PROVISO | | | FUEL GAS APPROVED WITH EXCEPTION! | | | | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | NOTE: A SEPARATE PERMIT WILL ALSO NEED TO BE OBTAINED | | | FOR A FUEL GAS PERMIT. SHEET P301 SHOWS THE GAS | | | ISOMETRIC. THESE ARE THE REQUIREMENTS TO OBTAIN A FUEL | | | GAS PERMIT: | | | | | | 1) WITHOUT THE SUBMITTAL OF THE MANUFACTURERS | | | SPECIFICATION SHEETS FOR THE GAS EQUIPMENT TO BE | | | INSTALLED SIZING CAN NOT BE VARIFIED, CONTRACTOR IS AT | | | OWN RISK. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND FBC-2010 FUEL GAS SEC. 402.2. THE | | | MANUFACTURER'S SPECIFICATIONS CAN BE SUBMITTED AS A | | | DEFERRAL BUT AT RISK. | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-08-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-08 |
Time |
06:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-07 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2014-08-07 16:32:31 | INCOMING SENT TO ZONING, ERIC TOOK PLANS TO 2ND FLOOR. | | | JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-08-07 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-08-07 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-07-24 |
Time |
06:35 |
Sent To |
|
|
| Notes |
| 2014-07-25 09:20:13 | SENT TO C-26. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-07-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-07-21 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-06-18 |
Time |
19:15 |
Sent To |
|
|
| Notes |
| 2014-06-18 19:15:47 | INCOMING SENT TO C-32. JW |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-08-07 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-08-07 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-08-07 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2014-08-07 13:42:19 | PASS PROVISO | | | | | | 1) SEPARATE APPLICATION, PLAN AND PERMIT REQUIRED FOR | | | HOODS AND COOLERS | | | 2) PROVIDE ENGINEER DETAIL ON ROOF TOP FANS TIED TO | | | CURB BY FINAL INSPECTION | | | PER SECTION 301.12 WIND RESISTANCE | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-07-21 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-07-17 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2014-07-21 13:20:46 | PLAN DENIED | | | 1) SEPARATE PLANS, APPLICATION AND PERMIT REQUIRED FOR | | | HOOD AND REFRIGATION. PER SECTION 107 FBC 2010 | | | 2) PROVIDE ENGINEER DETAIL ON THE HOOD EXHAUST FAN AND | | | SUPPLY FANS, CURB TIE DOWN TO THE ROOF AND FAN TIE DOWN | | | TO CURB. PROVIDE SPACING ON THE ANCHOR PROVIDE TYPE | | | AND SIZE OF ANCHOR USED. ON HOOD PLANS. PER SECTION | | | 301.12 WIND RESISTANCE 2010 FBC (M) | | | 3) PROVIDE AN ENGINEER DETAIL ON REFRIGATION CONDENSER | | | STAND | | | TIE DOWN TO ROOF AND CONDENSER TIE DOWN TO STAND. PER | | | SECTION | | | 301.12 WIND RESISTANCE 2010 FBC (M). | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-06 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-25 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2014-08-06 12:05:24 | PLUMBING PLAN REVIEW | | | PERMIT: 14060781 | | | ADD: 1845 PALM BEACH LAKES (WHOLE FOODS) | | | CONT: TO BE DETERMINED | | | TEL: (561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. AUG. 08/2014 | | | ACTION: PLUMBING PROVISO | | | | | | 1) NOTE TO DATE NO PERMIT HAS BEEN BROUGHT IN FOR THE | | | SIZING OF THE CONCRETE VAULT TYPE INTERCEPTOR FOR THIS | | | TENANT SPACE, NOR REVIEWED FOR CODE COMPLIANCE BY THE | | | BUILDING DEPARTMENT. THE GREASE INTERCEPTOR THAT WAS | | | SET UNDER THE CIVIL PLANS OF THE PALM BEACH OUTLET MALL | | | DID NOT HAVE SIZING INFORMATION FOR THE OUT PARCELS AND | | | MAY OR MAY NOT BE SIZED ADEQUATELY TO MEET THE DEMANDS | | | FOR THIS USAGE OF THIS TENANT. THIS GREASE INTERCEPTOR | | | IS A CONCRETE VAULT TYPE INTERCEPTOR AND SHOULD BE | | | SIZED USING THE 2010 FBC-P (TABLE 1003.5.1 THIS IS A | | | FLORIDA SPECIFIC AMENDMENT TO THE ICC BASE CODE). MV+A | | | IS USING THE SIZING METHOD OF "DFU" METHOD OF SIZING | | | WHICH IS FOR HYDROMECHANICAL TYPE INTERCEPTORS. | | | | | | THE CITY FOG INSPECTORS (FATS, OILS & GREASE) MONITOR | | | ALL GREASE INTERCEPTORS TO VERIFY COMPLIANCE WITH THE | | | CITY?S MUNI CODE SEC. 90-126. PROHIBITIONS AND | | | LIMITATIONS OF DISCHARGE.(7) MINERAL OIL IN EXCESS OF | | | 50 MG/L OR ANIMAL/VEGETABLE FATS, WAX, GREASE, OR OILS | | | IN EXCESS OF 100 MG/L, WHETHER EMULSIFIED OR NOT; OR | | | SUBSTANCES WHICH MAY SOLIDIFY OR BECOME VISCOUS AT | | | TEMPERATURES LOWER THAN OR EQUAL TO 150 DEGREES | | | FAHRENHEIT (65.56 DEGREES CELSIUS). | | | | | | IF THIS AMOUNT OF FATS, OILS OR GREASE IS EXCEEDED THE | | | REQUIRED MAINTENANCE & PUMP-OUT SCHEDULE WILL BE | | | INCREASED TO KEEP IN COMPLIANCE WITH THE CITY'S | | | MUNICIPAL CODE OF ORDINANCES. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-06-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-30 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-28 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2014-06-30 15:22:41 | PLUMBING PLAN REVIEW | | | PERMIT: 14060781 | | | ADD: 1845 PALM BCH LAKES BLVD BLDG "C" WHOLE FOODS | | | CONT: TBD | | | TEL: (561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JUNE 30/ 2014 | | | ACTION: DENIED | | | | | | 1) A SEPARATE PERMIT IS REQUIRED FOR GREASE | | | INTERCEPTORS. SHEET P101 INDICATES THERE IS A EXISTING | | | 4 INCH EXISTING GREASY BUILDING DRAIN. NOTE TO DATE | | | THERE HAS BEEN NO GREASE INTERCEPTOR APPLIED FOR OR | | | REVIEWED BY THIS DEPARTMENT. THERE IS APPARENTLY GREASE | | | INTERCEPTORS THAT WERE REVIEWED BY THE ENGINEERING | | | DEPARTMENT BUT NOT BY THE BUILDING DEPARTMENT. ALL | | | GREASE INTERCEPTORS ARE TO COMPLY WITH THE 2010 | | | FBC-PLUMBING , IF THIS IS A CONCRETE VAULT TYPE OF | | | GREASE INTERCEPTORS THEY ARE TO BE DESIGNED TO FBC- | | | PLUMBING TABLE 1003.5.1. | | | | | | 2) A SEPARATE PERMIT WILL ALSO NEED TO BE OBTAINED FOR | | | A FUEL GAS PERMIT. SHEET P301 SHOWS THE GAS ISOMETRIC. | | | THESE ARE THE REQUIREMENTS TO OBTAIN A FUEL GAS PERMIT: | | | | | | 2.1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE, DIAMETER AND CORRESPONDING | | | LENGTHS PER FBC-2010 FUEL GAS. | | | | | | 2.2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EDH NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | 2.3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 2.4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD | | | ON THE SYSTEM. REFER TO THE FBC-2010 FUEL GAS SECS. | | | 401.8 THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(35) | | | | | | 2.5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2010 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) | | | | | | 2.6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2010 FUEL GAS CODE SEC. 304 | | | | | | 2.7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2010 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 2.8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE | | | AND TERMINATION OF THE GAS VENTS PER FBC-2010 FUEL GAS | | | CODE SEC. 502 THRU 505. | | | | | | 2.9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2010 FUEL GAS SEC. 402.2 | | | | | | 3) PLEASE PROVIDE ADDITIONAL INFORMATION 107.2.1.3. | | | SHEET A101 IN (2) OF THE REFRIGARATED ROOMS THERE IS | | | EQUIPMENT IDENTIFIED AS EQ. 801 GRINDER THIS EQUIPMENT | | | DOES NOT SHOW UP ON P101 NOR P401, IS A DETAIL ON P402 | | | IF THIS IS PART OF THE PLUMBING SYSTEM, THAT SHOULD GO | | | TO THE GREASY WASTE NOT LOCATED ON PLANS, THEY WILL | | | NEED TO COMPLY WITH 2010 FBC-P 1003.3.2 PROVIDE THE | | | MANUFACTURERS SPECIFICATIONS. . | | | | | | 4) NEITHER P101 NOR P102 INDICATE THE AMOUNT OF | | | DRAINAGE FIXTURE UNITS ON THE HORIZONTAL FIXTURE | | | BRANCHES (TABLE 710.1(2) NOR THE BUILDING DRAIN FOR THE | | | SANITARY OR GREASY WASTE TABLE 710.1(1). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2014-08-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-08-07 |
Time |
16:57 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2014-08-07 |
Time |
16:57 |
Sent To |
B |
|
| Notes |
| 2014-08-07 16:58:18 | ALL ROOFTOP MECHANICAL EQUIPMENT SHALL BE SCREENED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-07-29 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-07-29 |
Time |
09:34 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2014-07-29 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2014-07-29 10:29:38 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | | | 1) REPEAT COMMENT: THE APPROVED SHELL PERMIT SHOWS A | | | BUILDING SQUARE FOOTAGE OF 41,534 SQ. FT FOR THE GROUND | | | FLOOR AND 1,198 SQ. FT. FOR THE MEZZANINE. THE INTERIOR | | | BUILD OUT PERMIT LISTS A SQUARE FOOTAGE OF 40,636 SQ. | | | FT. FOR THE GROUND FLOOR AND 925 SQ. FT. FOR THE | | | MEZZANINE. PLEASE EXPLAIN AND CORRECT THE DISCREPANCY. | | | | | | 2) REPEAT COMMENT: SHEET A408 (COFFEE BAR DETAILS) WAS | | | NOT INCLUDED WITH THE PERMIT APPLICATION YET IS | | | REFERENCED ON SHEET A204, A205. | | | | | | 3) REPEAT COMMENT: NO INFORMATION IS INCLUDED FOR THE | | | HEIGHT, FROM THE ROOF, OF THE NEW ROOFTOP EQUIPMENT (TO | | | INCLUDE THE EXHAUST FANS AND MAKE UP FANS) INCLUDING | | | THE CURBS THEY WILL BE MOUNTED ON. VERIFY THAT THE NEW | | | EQUIPMENT IS SCREENED IN ACCORDANCE WITH THE PALM BEACH | | | OUTLETS DESIGN GUIDELINES. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-06-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-06-27 |
Time |
11:15 |
Rev Time |
2.00 |
| Received By |
eschneid |
Date |
2014-06-27 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2014-06-27 15:14:44 | FAILED | | | | | | 1) THE APPROVED SHELL PERMIT SHOWS A BUILDING SQUARE | | | FOOTAGE OF 41,534 SQ. FT FOR THE GROUND FLOOR AND 1,198 | | | SQ. FT. FOR THE MEZZANINE. THE INTERIOR BUILD OUT | | | PERMIT LISTS A SQUARE FOOTAGE OF 40,636 SQ. FT. FOR THE | | | GROUND FLOOR AND 925 SQ. FT. FOR THE MEZZANINE. PLEASE | | | EXPLAIN AND CORRECT THE DISCREPANCY. | | | | | | 2) SHEET A408 WAS NOT INCLUDED WITH THE PERMIT | | | APPLICATION YET IS REFERENCED ON THE SHEETS THAT ARE | | | INCLUDED. | | | | | | 3) NO INFORMATION IS INCLUDED FOR THE HEIGHT, FROM THE | | | ROOF, OF THE NEW ROOFTOP EQUIPMENT (TO INCLUDE THE | | | EXHAUST FANS AND MAKE UP FANS) INCLUDING THE CURBS THEY | | | WILL BE MOUNTED ON. VERIFY THAT THE NEW EQUIPMENT IS | | | SCREENED IN ACCORDANCE WITH THE PALM BEACH OUTLETS | | | DESIGN GUIDELINES. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | 2014-06-25 11:34:42 | 6/25/14 |
|
|