Plan Review Details - Permit 14060543
| Plan Review Stops For Permit 14060543 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-06-30 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-06-30 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-06-30 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-06-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-06-17 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-06-17 |
Time |
06:49 |
Sent To |
FIRE |
|
| Notes |
| 2014-06-17 07:21:41 | 1ST REVIEW: | | | | | | THE DOOR/WINDOW REPLACEMENT ASPECT OF THIS PROJECT IS | | | REQUIRED TO BE EVALUATED BY A DESIGN PROFESSIONAL. | | | PLEASE PROVIDE AN ENGINEERED WIND DESIGN WHICH | | | CONSIDERS BUILDING HEIGHT, WIND SPEED, WIND EXPOSURE, | | | AND LOCATION OF THE OPENINGS. THE PROPOSED INSTALLATION | | | MUST MEET THE RESULTING DESIGN PRESSURES. | | | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, THE CONSTRUCTION DOCUMENTS | | | SHALL BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL | | | WHERE REQUIRED BY CHAPTER 471, FLORIDA STATUTES& 61G15 | | | FLORIDA ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA | | | STATUTES& 61G1 FLORIDA ADMINISTRATIVE CODE. | | | | | | FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-CHAPTER 16 | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-06-16 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-06-13 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-13 |
Time |
07:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-06-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-06-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-06-17 |
Time |
14:45 |
Sent To |
PC |
|
| Notes |
| 2014-06-17 15:06:20 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-06-30 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-06-30 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-06-24 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2014-06-24 17:12:50 | SENT TO S KENNEDY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-06-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-06-17 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-06-13 |
Time |
07:28 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-06-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-06-17 |
Time |
06:48 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-06-17 |
Time |
06:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-06-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-06-17 |
Time |
06:48 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-06-17 |
Time |
06:48 |
Sent To |
|
|
| Notes |
|
|
|