| Plan Review Stops For Permit 14060484 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-08-13 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-19 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2014-08-19 12:25:48 | BUILDING PLAN REVIEW | | | PERMIT: 14060484 | | | ADD: 900 FLORIDA AVENUE | | | CONT: COSTAL | | | TEL: (561)659-5919 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUESDAY AUG. 19/2014 | | | ACTION: BUILDING PROVISO | | | | | | 1) THE ARCHITECTURAL SHEETS FOR THE STAIRS AND RAMP | | | WILL NEED TO SHOW COMPLIANCE WITH THE 2010 FBC-B | | | HANDRAIL EXTENSIONS IN COMPLIANCE WITH 505.10 FIGURE | | | 505.10.1 AND PROTRUDING LIMITS 307.2. | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-01 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-01 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2014-07-01 07:57:13 | BUILDING PLAN REVIEW | | | PERMIT: 14060484 | | | ADD: 900 FLORIDA AVENUE | | | CONT: COSTAL | | | TEL: (561)659-5919 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUESDAY JULY 01/2014 | | | ACTION: DENIED | | | | | | 1) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | 1. SITE REQUIREMENTS: | | | SITE PLAN, LOCATION OF MODULAR BUILDING ON LOT. | | | PARKING | | | | | | 2) THE STATE APPROVED PLANS INDICATE ITEMS THAT ARE | | | SITE INSTALLED: | | | 2A) ACCESSIBLE RAMP HANDRAIL /GUARDRAIL, & STAIRS 1009: | | | STAIRS, 1010: RAMPS, 1012 HANDRAILS & 1013 GAURDS. | | | 2B) BUILDING DRAINAGE AND CLEAN OUT 107.3.5.1.3 (4) | | | SANITARY DRAINAGE | | | 2C) STORM SHUTTERS | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | | COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: (31)(E) | | | STORM SHUTTERS | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-08-27 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-08-27 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-27 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-08-05 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-08-05 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-05 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2014-08-05 07:41:48 | DATE: 8/5/2014 | | | PROJECT: CONSTRUCTION TRAILER | | | PERMIT#: 14060484 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) ACCORDING TO THE CONTRACTOR'S RESPONSE LETTER TO THE | | | PREVIOUS ELECTRICAL COMMENTS THE PLANS SUBMITTED ON | | | PERMIT #14070239 HAVE THE INFORMATION REQUESTED. | | | THE LOAD CALCULATION SUBMITTED INDIACTES A LOAD OF 63.4 | | | AMPS ON PANEL A AND 60.5 AMPS AN PANEL B. I PULLED THE | | | PLANS FROM PERMIT #14070239 AND DETERMINED THAT THE | | | RISER DIAGRAM ON THAT PERMIT INDICATE A 60AMP FEEDER TO | | | EACH PANEL WHICH WOULD BE UNDERSIZED FOR THE LOAD. | | | EITHER SUBMIT A REVISION TO PERMIT #14070239 WITH A | | | CORRECTED RISER DIAGRAM WITH ADAQUATE AMPACITY TO | | | SUPPORT THE LOAD TO BE SERVED OR RE-SUBMIT THIS PERMIT | | | APPLICATION WITH A RISER DIAGRAM WITH ADAQUATE AMPACITY | | | TO SUPPORT THE LOAD TO BE SERVED. | | | | | | 2) ACCORDING TO THE CONTRACTORS RESPONSE LETTER UNDER | | | THE PLUMBING REVIEW COMMENTS DRINKING FOUNTAINS WILL BE | | | PROVIDED. THE CUT SHEET SUBMITTED WITH THE RE-SUBMITTAL | | | ARE FOR ELECTRICAL DRINKING FOUNTAINS THAT REQUIRE A | | | GFI PROTECTED OUTLET. SEE NEC 422.52 ELECTRIC DRINKING | | | FOUNTAINS. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-07-07 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-07 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-07 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2014-07-07 15:03:22 | DATE: 7/7/2014 | | | PROJECT: HILTON HOTEL | | | PERMIT#: 14060484 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | ELECTRICAL PLANS REQUIRED FOR THE FOLLOWING: | | | | | | 1) LOAD CALCULATION TO INDICATE THE TOTAL CONNECTED | | | LOAD AT TRAILER. | | | 2) SITE TO SHOW LOCATION OF TRAILER RELATIVE TO UTILITY | | | SOURCE AND SERVICE EQUIPMENT REQUIRED TO FEED TRAILER. | | | 3) A ONE LINE RISER DIAGRAM TO INDICATE SIZE AND TYPE | | | OF PIPE AND WIRE FROM UTILITY TO MAIN SERVICE | | | DISCONNECT TO DISTRIBUTION TO TRAILER. CONFIRM AMPACITY | | | OF CONDUCTORS ARE ADAQUATE TO SUPPORT TOTAL CONNECTED | | | LOAD COMPUTED IN LOAD CALCULATION. | | | 4) A PANEL SCHEDULE TO INDICATE OCP AND CIRCUITS | | | INVOLVED. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-08-13 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-08-13 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-08-13 |
Time |
11:01 |
Sent To |
B |
|
| Notes |
| 2014-08-13 11:29:05 | 900 FLORIDA AVENUE - CONSTRUCTION TRAILERS | | | PERMIT #14060484 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ****PROVISO**** | | | | | | NEED A #131 FIRE FINAL INSPECTION BEFORE OCCUPYING THE | | | MODULAR BUILDINGS. | | | | | | PER SECTION 10.12.1.2 (NFPA 1), PROVIDE BUILDING | | | ADDRESS VISIBLE FROM THE STREET. NUMBERS/LETTERS SHALL | | | BE ATTACHED TO THE BUILDING AND BE AT LEAST SIX-INCHES | | | IN HEIGHT WITH 1-INCH STROKE AND SHALL CONTRAST THE | | | BACKGROUND. | | | | | | COULD NOT LOCATE ANY EXTERIOR LIGHTING ILLUMINATING THE | | | EXIT DISCHARGE TO THE PUBLIC WAY. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-06-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-06-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-06-12 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2014-06-12 16:33:18 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE PERMIT APPLICATION DID NOT INCLUDE A SITE PLAN. A | | | SITE PLAN SHALL INDICATED THE LOCATION AND SEPARATION | | | DIMENSIONS OF THE TRAILER IN REFENCE TO PROPERTY LINES, | | | BUILDINGS, OTHER TRAILERS AND OTHER IMPORTANT | | | STRUCTURES. | | | | | | SEPARATION DISTANCES SHALL COMPLY WITH NFPA 241 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-08-27 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-08-27 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-20 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2014-08-20 18:02:49 | SENT TO D HAYES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-08-20 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-08-20 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2014-08-04 |
Time |
07:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-07-07 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-07 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-11 |
Time |
12:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-10-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-10-21 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-10-21 |
Time |
08:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-19 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-19 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-01 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-01 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2014-07-01 08:04:34 | PLUMBING PLAN REVIEW | | | PERMIT: 14060484 | | | ADD: 900 FLORIDA AVENUE | | | CONT: COSTAL | | | TEL: (561)659-5919 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUESDAY JULY 01/2014 | | | ACTION: DENIED | | | | | | 1) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.3 PLUMBING | | | | | | (2) FIXTURE REQUIEMENTS ACCESSIBLE DRINKING FOUNTAINS, | | | 2010 FL ACC CODE. 211.2 MINIMUM NUMBER. | | | NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. | | | ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH | | | 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.7 | | | | | | (4) SANITARY DRAINAGE | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-08-20 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-08-20 |
Time |
14:10 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2014-08-20 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2014-08-20 14:11:24 | THE DRIVE AISLE BEHIND THE ADA SPACE SHALL BE A MINIMUM | | | OF 24 FEET WIDE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-07-01 |
Time |
10:10 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2014-07-01 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2014-07-01 10:11:21 | FAILED | | | | | | 1) PROVIDE A SITE PLAN FOR THE TRAILER LOCATION AND FOR | | | THE PARKING TO SUPPORT THE CONSTRUCTION. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | 2014-06-13 11:34:28 | 6/13/14 |
|
|