| Plan Review Stops For Permit 14060384 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-07-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-26 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-26 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-06-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-11 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-11 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2014-06-11 10:43:44 | THE WINDOW IN THE SECOND FLOOR BATHROOM WHERE THE | | | CLOSET IS CONVERTED TO A SHOWER WILL BE REQUIRED TO | | | HAVE SAFETY GLAZING PER FBC R308.4. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-07-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-26 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-26 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2014-06-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-11 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-11 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2014-06-11 08:51:28 | NO ELECTRICAL WORK IS SHOWN ON THE PLANS AND NO | | | ELECTRICAL PERMIT APPLICATION WAS SUBMITTED. A SEPARATE | | | PERMIT, APPLICATION, PLANS AND REVIEW IS REQUIRED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2014-07-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-07-22 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2014-07-23 12:49:25 | TO RM DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-06-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-11 |
Time |
12:55 |
Rev Time |
|
| Received By |
rmcdouga |
Date |
2014-06-10 |
Time |
|
Sent To |
|
|
| Notes |
| 2014-06-11 10:12:29 | SENT TO ZONING BOX FOR REVIEW OF RELOCATED CONDENSING | | | UNIT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-07-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-26 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-26 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2014-07-26 07:53:14 | APPROVED WITH EXCEPTIONS. MAKE CORRECTIONS NOTED ON | | | PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-06-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-11 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-11 |
Time |
10:11 |
Sent To |
Z |
|
| Notes |
| 2014-06-11 08:54:35 | 2010 FBC | | | | | | DENIED BY MECHANICAL | | | | | | THE MECHANICAL PLANS SHOW NEW DUCT WORK AND THE SCOPE | | | OF WORK SPECIFIES THE EXISTING A/C UNIT IS TO BE | | | REPLACED AND RELOCATED. | | | | | | 1) SUBMIT TWO SETS OF EQUIPMENT SIZING CALCULATIONS AND | | | AHRI CERTIFICATIONS FOR THE NEW A/C EQUIPMENT. FBCR | | | M1401.3 | | | | | | 2) SPECIFY THE CFMS AT EACH SUPPLY OUTLET. CITY | | | AMENDMENTS 107.3.5.3 | | | | | | 3) SPECIFY THE SIZE OF THE SUPPLY DUCT FROM THE A/H TO | | | THE DISTRIBUTION BOX BY THE FIREPLACE AND THE SIZE OF | | | THE SUPPLY DUCT TO THE PANTRY ON THE PLANS. CITY | | | AMENDMENTS 107.3.5.3 | | | | | | 4) LABEL THE ROOM TYPES ON THE PLANS. (IE BEDROOM, | | | MASTER SUITE, ETC.) CITY AMENDMENTS 107.2.1 & 107.3.5.3 | | | | | | 5) SPECIFY THE SIZE OF THE RETURN AIR DUCT. CITY | | | AMENDMENTS 107.3.5.3 | | | | | | 6) SHOW COMPLIANCE WITH FBCR M1602.4 FOR BALANCED | | | RETURN AIR. | | | | | | 7) THE PLANS HAVE WHAT APPEARS TO BE A DISCONNECT IN | | | THE ROOM IN FRONT OF THE FIREPLACE. PLEASE CLARIFY. | | | CITY AMENDMENTS 107.2.1 | | | | | | 8) A DISCONNECT AND APPLIANCE SERVICE RECEPTACLE OUTLET | | | WILL BE REQUIRED FOR THE RELOCATED CONDENSING UNIT. NEC | | | 440.11 & 210.63 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-07-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-26 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-26 |
Time |
06:43 |
Sent To |
|
|
| Notes |
| 2014-07-26 06:45:14 | APPROVED WITH EXCEPTIONS. MAKE CORRECTIONS NOTED ON | | | PLANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-06-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-11 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-11 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2014-06-11 10:45:58 | REDLINED PLANS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-06-11 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2014-06-11 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2014-06-11 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|