Plan Review Details - Permit 14060196
| Plan Review Stops For Permit 14060196 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-29 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-29 |
Time |
05:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-07-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-26 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-26 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2014-07-26 11:09:08 | BUILDING PLAN REVIEW | | | PERMIT: 14060196 | | | ADD:777 S FLAGLER 12TH FLOOR | | | CONT: WOOLEMS | | | TEL: (561)835-0401 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: SAT. JULY 26/2014 | | | ACTION: DENIED | | | | | | 1-2) COMPLIED. | | | | | | 3)2ND REQUEST. SHEET A0.08 LIFE SAFETY PLANS:MISSING | | | PLAN REVIEW CRITERIA: | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS | | | SHALL BE DETERMINED. | | | OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | OCCUPANCY LOAD | | | GROSS OR NET TABLE FBC-B 1004.1.1. PER FLOOR | | | | | | 4) THE STRUCTURAL WORK ON THIS BUILDING ISCLASSIFYING | | | IT AS A :THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) " | | | THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH | | | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN | | | THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN AREA | | | AND AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS. | | | | | | 4A) COMPLIED. | | | | | | 4B) THRESHOLD INSPECTOR: | | | WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES | | | DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL | | | INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA | | | STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS | | | CODE. A THRESHOLD AGREEMENT WILL NEED TO BE SIGNED BY | | | ALL PARTIES, PLEASE PROVIDE A E-MAIL ADDRESS THAT WE | | | CAN SEND ALL THE REQUIRED DOCUMENTS. | | | | | | 4C) COMPLIED. | | | | | | | | | 4D) CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR | | | PROGRAM AT (561)805-6666 OR [email protected] FOR FURTHER | | | INFORMATION: | | | | | | 4D) (1) COMPLIED. THE CONTRACTOR WILL PRODUCE A JOB | | | SUMMARY OR HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | | | 4D) (2) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A | | | RESUME' OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. | | | THE RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | CONTACT KEN CONRAD | | | TEL: 561-805-6666 | | | E-MAIL: [email protected] | | | | | | 5) COMPLIED. | | | | | | 6) SHEET 015 A1.10 LEVEL 15: | | | | | | 6A) DOOR # 1502 APPEARS TO HAVE ONLY 16 1/2 INCHES ON | | | THE LATCH SIDE OF THE DOOR, SEE 2010 FL ACC CODE FIGURE | | | 404.2.4.1. (A). | | | | | | 6B) COMPLIED. | | | | | | 6C) COMPLIED. | | | | | | 7) 2ND REQUEST ,RESPONSE INDICATES DETAILS FOR FIRE | | | RESISTANCE IS FOUND ON SHEET A0.04. THERE ARE NO | | | DETAILS SHOWING CODE COMPLIANCE. | | | STRUCTURAL SHEETS SHOW STEEL FRAMING MEMBERS, THIS IS A | | | TYPE 1A BUILDING SHOW COMPLIANCE WITH TABLE 603 WITH | | | REQUIRED FIRE RESISTANCE RATING REQUIREMENTS FOR | | | BUILDING ELEMENTS (HOURS) PROVIDE THICKENESS AND HOUR | | | RATING. | | | | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | NOTE THERE ARE ALOT OF THE REQUIRED DOCUMENTS PRODUCT | | | APPROVALS AND MANUFACTURERS SPECIFICATIONS THAT WERE | | | LOADED INTO THE RESPONSE FOLDER RATHER THAN A SEPARATE | | | DOCUMENT FOLDER. I'LL BE CHECKING IF OUR LIBRIAN WILL | | | BE ABLE TO TRANSFER THESE ITEMS INTO THE CORRECT | | | FOLDER. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-07 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-07 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2014-07-07 12:33:58 | BUILDING PLAN REVIEW | | | PERMIT: 14060196 | | | ADD:777 S FLAGLER 12TH FLOOR | | | CONT: WOOLEMS | | | TEL: (561)835-0401 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JULY 07/2014 | | | ACTION: DENIED | | | | | | 1) THE PLANS DO NOT PROVIDE THE ADDRESS WHERE THE WORK | | | IS TO OCCUR. FL S 61G-16.004(3) LOCATION OF PROJECT. | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 2) THE SCOPE OF THIS PROJECT WILL NEED SOME EXPLAINING. | | | THE PERMIT APPLICATION INDICATES WORK TO BE | | | ACCOMPLISHED UNDER THIS PERMIT ON THE 12TH & 13TH | | | FLOORS. WHERE AS PLANS INDICATE 007-A0.07 12-14 FLOORS, | | | 011-A1.04 DEMO 15TH FLOOR & 015-A1.10 CONSTRUCTION | | | PLANS FOR THE 15TH LEVEL. IS THIS A PHASED PERMIT OR IS | | | THE SCOPE OF WORK TO INCLUDE ALL THESE FLOORS? | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 3) SHEET A0.08 LIFE SAFETY PLANS:MISSING PLAN REVIEW | | | CRITERIA: | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS | | | SHALL BE DETERMINED. | | | MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED (SEE | | | TABLE 503). | | | OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | OCCUPANCY LOAD | | | GROSS OR NET TABLE FBC-B 1004.1.1. PER FLOOR | | | | | | 4) THE STRUCTURAL WORK ON THIS BUILDING ISCLASSIFYING | | | IT AS A :THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) " | | | THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH | | | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN | | | THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN AREA | | | AND AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS. | | | | | | 4A) 109.3.6.1 THE ENFORCING AGENCY SHALL REQUIRE A | | | SPECIAL INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON | | | A THRESHOLD BUILDING PURSUANT TO A STRUCTURAL | | | INSPECTION PLAN PREPARED BY THE ENGINEER OF RECORD. THE | | | STRUCTURAL INSPECTION PLAN MUST BE SUBMITTED TO THE | | | ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A BUILDING | | | PERMIT FOR THE CONSTRUCTION OF A THRESHOLD BUILDING. | | | THE PURPOSE OF THE STRUCTURAL INSPECTION PLAN IS TO | | | PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO | | | THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR | | | COMPLIANCE WITH THE PERMITTED DOCUMENTS. | | | | | | 4B) THRESHOLD INSPECTOR: | | | WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES | | | DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL | | | INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA | | | STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS | | | CODE. A THRESHOLD AGREEMENT WILL NEED TO BE SIGNED BY | | | ALL PARTIES, PLEASE PROVIDE A E-MAIL ADDRESS THAT WE | | | CAN SEND ALL THE REQUIRED DOCUMENTS. | | | | | | 4C) THRESHOLD BLDG, REQUIRED STATEMENT: | | | W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING | | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE | | | LOCAL AUTHORITY IN | | | ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE. | | | | | | | | | 4D) CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR | | | PROGRAM AT (561)805-6666 OR [email protected] FOR FURTHER | | | INFORMATION: | | | 4D) (1) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | | HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | 4D) (2) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A | | | RESUME' OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. | | | THE RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | CONTACT KEN CONRAD | | | TEL: 561-805-6666 | | | E-MAIL: [email protected] | | | | | | 4E) PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR | | | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS. | | | | | | 4F) A COLLOR COPY OF THE PLANS WILL BE REQUIRED AT THE | | | JOBSITE FOR CITY INSPECTORS & A SECOND COLOR COPY FOR | | | THE THRESHOLD INSPECTOR. | | | | | | 4G) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES | | | FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER | | | HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE | | | MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR | | | WALLS AND CEILINGS. | | | | | | 5) SHEET 013 A1.09: | | | 5A) ROOM 1405, THE PRIVATE EXECUTIVE RESTROOM, IT | | | APPEARS THERE ARE CURVED WALLS WITH A POCKET DOOR, IT | | | APPEARS THE POCKET IS OUTSIDE OF THE WALL. 107.2,1,3 | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 5B) PRIVATE ELEVATOR SWING DOOR 1406 ANY DOOR IN A | | | MEANS OF EGRESS SHALL LEAVE UNOBSTRUCTED AT LEAST ONE | | | HALF OF THE REQUIRED WIDTH OF THE PASSAGEWAY. 2010 | | | FBC-B 1008.1.9.11. | | | | | | 5C) EXTERIOR BALCONY 1450A NOTE FOR NEW BALCONIES SHALL | | | BE AMERICAN HYDROTECH CONCRETE PAVER SYSTEM NOA | | | 08-0422.12 NOTE THIS IS NOT A PAVER SYSTEM BUT A | | | WATERPROOFING SYSTEM. THIS IS A EXPIRED NOA . PLEASE | | | PROVIDE A CURRENT APPROVAL AND TYPE OF DECKING SYSSTEM | | | THAT WILL BE APPLIED ON TOP OF THE WATERPROOFING | | | SYSTEM. | | | | | | 5D) SHOWER ROOMS 1432 (MENS) & 1433 (LADIES) BOTH SHOW | | | SHOWERS BUT THE PLANS DO NOT INDICATE SIZE OF THE | | | SHOWER NOR A SEAT DETAIL AS REQUIRED BY 2010 FL ACC | | | CODE 608.2.1. | | | | | | 5E) THE PLANS INDICATE A EXTERIOR DINING AREA (1426) | | | PLEASE PROVIDE COMPLIANCE WITH THE 2010 FL | | | ACCESSIBILITY CODE 404.2.5 THRESHOLDS. | | | | | | 5F) THE NEW MONUMENTAL STAIRS WILL NEED TO PROVIDE | | | DETAILS THAT WILL SHOW COMPLIANCE WITH THE 2010 FBC-B | | | 708.2 EXCEPTION 2.1 WHERE THE AREA OF THE FLOOR OPENING | | | BETWEEN STORIES DOES NOT EXCEED TWICE THE HORIZONTAL | | | PROJECTED AREA OF THE ESCALATOR OR STAIRWAY AND THE | | | OPENING IS PROTECTED BY A DRAFT CURTAIN AND CLOSELY | | | SPACED SPRINKLERS IN ACCORDANCE WITH NFPA 13. IN OTHER | | | THAN GROUPS B AND M, THIS APPLICATION IS LIMITED TO | | | OPENINGS THAT DO NOT CONNECT MORE THAN FOUR STORIES. | | | | | | 6) SHEET 015 A1.10 LEVEL 15: | | | | | | 6A) DOOR # 1502 APPEARS TO HAVE ONLY 16 1/2 INCHES ON | | | THE LATCH SIDE OF THE DOOR, SEE 2010 FL ACC CODE FIGURE | | | 404.2.4.1. (A). | | | | | | 6B) THE GYM IS ON THE 15 FLOOR LEVEL AND ONLY 1 MEANS | | | OF EGRESS. PLEASE SEE 2010 FBC-B TABLE 1021.2. | | | | | | 6C) A/C EQUIPMENT HATCH DETAIL # 1 A5.03 PROVIDE THE | | | MANUFACTURERS SPECIFICATIONS ON THE ACUDOOR FLOOR DOOR | | | PROVIDE FLOOR LOADING TABLE 1607(LBS) AND FIRE RATING | | | TABLE 715.4. FOR THE FLOOR DOOR. | | | | | | 7) STRUCTURAL SHEEETS SHOW STEEL FRAMING MEMBERS, THIS | | | IS A TYPE 1A BUILDING SHOW COMPLIANCE WITH TABLE 603 | | | WITH REQUIRED FIRE RESISTANCE RATING REQUIREMENTS FOR | | | BUILDING ELEMENTS (HOURS) PROVIDE THICKENESS AND HOUR | | | RATING. | | | | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-08-27 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-08-27 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-27 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2014-08-27 15:01:25 | DATE: 7/9/2014 | | | PROJECT: AMG PHILLIPS POINT EXPANSION | | | PERMIT#: 14060196 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 3RD ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) BOXES, CONDUIT BODIES, AND HANDHOLE ENCLOSURES SHALL | | | BE INSTALLED SO THAT THE WIRING CONTAINED IN THEM CAN | | | BE RENDERED ACCESSIBLE WITHOUT REMOVING ANY PART OF THE | | | BUILDING OR, IN UNDERGROUND CIRCUITS, WITHOUT | | | EXCAVATING SIDEWALKS, PAVING, EARTH, OR OTHER SUBSTANCE | | | THAT IS TO BE USED TO ESTABLISH THE FINISHED GRADE. NEC | | | 314.29. THE POWER PACKS FOR MOTION SENSORS APPEAR TO BE | | | LOCATED IN AREAS WITH DRYWALL CEILINGS. ALL | | | TRANSFORMERS, LED DRIVERS JUNCTION BOXES, POWER PACK | | | AND THE LIKE SHALL BE INSTALLED SO AS TO REMAIN | | | ACCESSIBLE AFTER INSTALLATION AND CONSTRUCTION IS | | | COMPLETE. | | | | | | 2) PROVIDE PRODUCT APPROVALS FOR ALL FIXTURES. LISTING | | | AND LABELING REQUIRED BY AN APPROVED TESTING LAB. IN | | | JUDGING EQUIPMENT, CONSIDERATION SUCH AS THE FOLLOWING | | | SHALL BE EVALUATED: SUITABILITY FOR INSTALLATION AND | | | USE IN CONFORMITY WITH THE PROVISIONS OF THIS CODE. NEC | | | 110.3(A)(1 THRU 8) | | | | | | 3) PROVIDE PRODUCT APPROVALS AND CUT SHEETS FOR FLOOR | | | BOXES TO SHOW CODE COMPLIANCE WITH FIRE RATING FROM | | | FLOOR TO FLOOR. ADDITIONAL INFORMATION REQUIRED. FBC | | | 107.2.1.3 | | | | | | 4) PROVIDE MANUFACTURER DATA SHEETS ON THE CEO | | | ELEVATOR. | | | | | | 5) WHERE A REQUIRED FIRE ALARM SYSTEM IS OUT OF SERVICE | | | FOR MORE THAN 4 HOURS IN A 24-HOUR PERIOD, THE AHJ | | | SHALL BE NOTIFIED, AND THE BUILDING SHALL BE EVACUATED | | | OR AN APPROVED FIRE WATCH SHALL BE PROVIDED FOR ALL | | | PARTIES LEFT UNPROTECTED BY THE SHUTDOWN UNTIL THE FIRE | | | ALARM SYSTEM HAS BEEN RETURNED TO SERVICE. | | | [101:9.6.1.6] NFPA-1, CHAPTER 13 SECTION 13.7.1.4.4 | | | | | | 6) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, PLANS, AND SHOP | | | DRAWINGS AS REQUIRED FOR, FIRE ALARM, SECURITY, ACCESS | | | CONTROL, CCTV, DATA/COM, NETWORK, STRUCTURED CABLING, | | | AUDIO/VIDEO, AND SIGNAGE. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-07-31 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-31 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-31 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2014-07-31 13:41:27 | DATE: 7/31/2014 | | | PROJECT: AMG PHILLIPS POINT EXPANSION | | | PERMIT#: 14060196 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) INDICATE THE LOCATION OF ELEVATOR MACHINE ROOM. | | | INDICATE ALL CIRCUITRY AND DISCONNECT FOR MOTOR AND | | | CONTROLS AND FIRE ALARM DEVICES REQUIRED IN THE | | | ELEVATOR MACHINE ROOM FOR THE PERSONAL CEO ELEVATOR. | | | | | | 2) CLEAR WORKING ACCESS REQUIRED FOR ELECTRICAL | | | EQUIPMENT, FEEDING MECHANICAL EQUIPMENT. | | | | | | 6) WHERE A REQUIRED FIRE ALARM SYSTEM IS OUT OF SERVICE | | | FOR MORE THAN 4 HOURS IN A 24-HOUR PERIOD, THE AHJ | | | SHALL BE NOTIFIED, AND THE BUILDING SHALL BE EVACUATED | | | OR AN APPROVED FIRE WATCH SHALL BE PROVIDED FOR ALL | | | PARTIES LEFT UNPROTECTED BY THE SHUTDOWN UNTIL THE FIRE | | | ALARM SYSTEM HAS BEEN RETURNED TO SERVICE. | | | [101:9.6.1.6] NFPA-1, CHAPTER 13 SECTION 13.7.1.4.4 | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-07-10 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-10 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-10 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2014-07-10 15:03:04 | DATE: 7/9/2014 | | | PROJECT: AMG PHILLIPS POINT EXPANSION | | | PERMIT#: 14060196 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) BOXES, CONDUIT BODIES, AND HANDHOLE ENCLOSURES SHALL | | | BE INSTALLED SO THAT THE WIRING CONTAINED IN THEM CAN | | | BE RENDERED ACCESSIBLE WITHOUT REMOVING ANY PART OF THE | | | BUILDING OR, IN UNDERGROUND CIRCUITS, WITHOUT | | | EXCAVATING SIDEWALKS, PAVING, EARTH, OR OTHER SUBSTANCE | | | THAT IS TO BE USED TO ESTABLISH THE FINISHED GRADE. NEC | | | 314.29. THE POWER PACKS FOR MOTION SENSORS APPEAR TO BE | | | LOCATED IN AREAS WITH DRYWALL CEILINGS. ALL | | | TRANSFORMERS, LED DRIVERS JUNCTION BOXES, POWER PACK | | | AND THE LIKE SHALL BE INSTALLED SO AS TO REMAIN | | | ACCESSIBLE AFTER INSTALLATION AND CONSTRUCTION IS | | | COMPLETE. | | | | | | 2) PROVIDE PRODUCT APPROVALS FOR ALL FIXTURES. LISTING | | | AND LABELING REQUIRED BY AN APPROVED TESTING LAB. IN | | | JUDGING EQUIPMENT, CONSIDERATION SUCH AS THE FOLLOWING | | | SHALL BE EVALUATED: SUITABILITY FOR INSTALLATION AND | | | USE IN CONFORMITY WITH THE PROVISIONS OF THIS CODE. NEC | | | 110.3(A)(1 THRU 8) | | | | | | 3) PROVIDE PRODUCT APPROVALS AND CUT SHEETS FOR FLOOR | | | BOXES TO SHOW CODE COMPLIANCE WITH FIRE RATING FROM | | | FLOOR TO FLOOR. ADDITIONAL INFORMATION REQUIRED. FBC | | | 107.2.1.3 | | | | | | 4) IDENTIFY ALL NEW FEEDERS ON THE RISER DIAGRAM. | | | ADDITIONAL INFORMATION REQUIRED. FBC 107.2.1.3 | | | | | | 5) ONE 125VOLT, SINGLE-PHASE, 15 OR 20AMP GFI | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE | | | LOCATION FOR THE SERVICING OF HEATING, | | | AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT. THE | | | RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND | | | WITHIN 25FT OF THE HEATING, AIR-CONDITIONING, AND | | | REFRIGERATION EQUIPMENT. THE RECEPTACLE OUTLET SHALL | | | NOT BE CONNECTED TO THE LOAD SIDE OF THE EQUIPMENT | | | DISCONNECTING MEANS. NEC 210.63 SEE 210.8(A)(3), ALL 15 | | | AND 20AMP, 125V AND 250V RECEPTACLES INSTALLED IN IN A | | | WET LOCATION SHALL HAVE AN ENCLOSURE THAT IS | | | WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS | | | INSERTED. ALL 15- AND 20-AMPERE, 125- AND 250-VOLT | | | NON-LOCKING RECEPTACLES SHALL BE LISTED | | | WEATHER-RESISTANT TYPE. NEC 406.8(B)(1) | | | | | | 6) WHERE A REQUIRED FIRE ALARM SYSTEM IS OUT OF SERVICE | | | FOR MORE THAN 4 HOURS IN A 24-HOUR PERIOD, THE AHJ | | | SHALL BE NOTIFIED, AND THE BUILDING SHALL BE EVACUATED | | | OR AN APPROVED FIRE WATCH SHALL BE PROVIDED FOR ALL | | | PARTIES LEFT UNPROTECTED BY THE SHUTDOWN UNTIL THE FIRE | | | ALARM SYSTEM HAS BEEN RETURNED TO SERVICE. | | | [101:9.6.1.6] NFPA-1, CHAPTER 13 SECTION 13.7.1.4.4 | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2014-09-05 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-09-05 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-09-05 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2014-07-30 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-07-30 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-07-30 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2014-07-30 11:13:58 | 777 SOUTH FLAGLER DRIVE | | | PERMIT #14060196 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | RESPONSE COMMENT: THE ARCHITECTURAL RESPONSE TO PROTECT | | | THE VERTICAL OPENING WITH SPRINKLERS IS TAKEN FROM | | | CHAPTER 39 (EXISTING BUSINESS) SECTION 39.3.1.1(3). IF | | | A MONUMENTAL STAIR WAS EXISTING, THIS WOULD BE | | | PERMITTED TO REMAIN; HOWEVER, BECAUSE THIS IS A NEW | | | STAIR INSTALLATION THE DESIGN NEEDS TO COMPLY WITH | | | CHAPTER 38 (NEW BUSINESS) WHICH REFERENCES SECTION | | | 8.6.8.2. ALLOWING AN UNPROTECTED STAIR TO BE | | | CONSTRUCTED WOULD CREATE A NONCONFORMITY THAT DID NOT | | | PREVIOUSLY EXIST. MONUMENTAL STAIR COMMUNICATES | | | DIRECTLY WITH CORRIDOR B, CORRIDOR C AND EXIT STAIR | | | DOOR. I HAVE SERIOUS CONCERNS THAT SMOKE COULD AFFECT | | | OCCUPANTS ABILITY TO EGRESS SAFELY. | | | | | | ORIGINAL COMMENT: SHEET A1.09: MONUMENTAL STAIR SHALL | | | COMPLY WITH SECTION 8.6.8.2 (CONVENIENCE OPENINGS) | | | WHEREBY THE FLOOR-TO-FLOOR OPENING IS REQUIRED TO BE | | | SEPARATED FROM CORRIDORS AND EXIT ACCESS INTO EXISTING | | | EXIT STAIR #1. | | | | | | RESPONSE COMMENT: DOORS TIED INTO THE FIRE ALARM SYSTEM | | | ONLY COMPLIES WITH 1 OF 15 REQUIREMENTS LIST BELOW. | | | ORIGINAL COMMENT: SHEET A1.21: ELEVATOR LOBBY DOORS ARE | | | EQUIPPED WITH CARD READERS. PER SECTION 7.2.1.6.3, EACH | | | ELEVATOR LANDING AND LOBBY SHALL HAVE ACCESS TO AT | | | LEAST ON EXIT. EXIT ACCESS SHALL NOT REQUIRE THE USE OF | | | A KEY, TOOL, SPECIAL KNOWLEDGE, OR SPECIAL EFFORT. | | | DOORS SEPARATING THE ELEVATOR LOBBY FROM THE EXIT | | | ACCESS SHALL BE PERMITTED TO BE ELECTRONICALLY LOCKED | | | IN ACCORDANCE WITH SECTION 7.2.1.6.3 ELEVATOR LOBBY | | | EXIT ACCESS DOOR ASSEMBLIES LOCKING: DOOR ASSEMBLIES | | | SEPARATING THE ELEVATOR LOBBY FROM THE EXIT ACCESS | | | SHALL BE PERMITTED TO BE ELECTRONICALLY LOCKED, | | | PROVIDED THAT ALL THE FOLLOWING CRITERIA ARE MET: | | | (1) THE ELECTRONIC SWITCH FOR RELEASING THE LOCK IS | | | LISTED IN ACCORDANCE WITH UL 294, STANDARD FOR ACCESS | | | CONTROL SYSTEM UNITS | | | (2) THE BUILDING IS PROTECTED THROUGHOUT BY A FIRE | | | ALARM SYSTEM | | | (3) THE BUILDING IS PROTECTED THROUGHOUT BY AN | | | APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM | | | (4) WATERFLOW IN THE SPRINKLER SYSTEM REQUIRED BY | | | 7.2.1.6.3(3) IS ARRANGED TO INITIATE THE BUILDING FIRE | | | ALARM SYSTEM. | | | (5) THE ELEVATOR LOBBY IS PROTECTED BY AN APPROVED, | | | SUPERVISED SMOKE DETECTION SYSTEM | | | (6) DETECTION OF SMOKE BY THE DETECTION SYSTEM REQUIRED | | | BY 7.2.1.6.3(5) IS ARRANGED TO INITIATE THE BUILDING | | | FIRE ALARM SYSTEM. | | | (7) INITIATION OF THE BUILDING FIRE ALARM SYSTEM BY | | | OTHER THAN MANUAL FIRE ALARM BOXES UNLOCKS THE ELEVATOR | | | LOBBY DOOR ASSEMBLY. | | | (8) LOSS OF POWER TO THE ELEVATOR LOBBY ELECTRONIC LOCK | | | SYSTEM UNLOCKS THE ELEVATOR LOBBY DOOR ASSEMBLIES. | | | (9) THE ELEVATOR LOBBY ELECTRONIC LOCK SYSTEM IS NOT | | | SUPPLIED WITH EMERGENCY OR STANDBY ELECTRICAL POWER. | | | (10) ONCE UNLOCKED, THE ELEVATOR LOBBY DOOR ASSEMBLIES | | | REMAIN UNLOCKED UNTIL THE BUILDING FIRE ALARM SYSTEM | | | HAS BEEN MANUALLY RESET. | | | (11) WHERE THE ELEVATOR LOBBY DOOR ASSEMBLIES REMAIN | | | LATCHED AFTER BEING UNLOCKED, LATCH-RELEASING HARDWARE | | | IS AFFIXED TO THE DOOR LEAVES. | | | (12) A TWO-WAY COMMUNICATION SYSTEM IS PROVIDED FOR | | | COMMUNICATION BETWEEN THE ELEVATOR LOBBY AND A CENTRAL | | | CONTROL POINT THAT IS CONSTANTLY STAFFED. | | | (13) THE CENTRAL CONTROL POINT STAFF REQUIRED BY | | | 7.2.1.6.3(12) IS CAPABLE, TRAINED, AND AUTHORIZED TO | | | PROVIDE EMERGENCY ASSISTANCE. | | | (14) THE PROVISIONS OF DELAYED-EGRESS LOCKING SYSTEMS | | | ARE NOT APPLIED TO THE ELEVATOR LOBBY DOOR ASSEMBLIES. | | | (15) THE PROVISIONS OF ACCESS-CONTROLLED EGRESS DOOR | | | ASSEMBLIES ARE NOT APPLIED TO THE ELEVATOR LOBBY DOOR | | | ASSEMBLIES. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-07-02 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-07-02 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-06-27 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2014-06-27 16:31:17 | 777 SOUTH FLAGLER DRIVE | | | PERMIT #14060196 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK INFORMATION. | | | | | | PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND | | | DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF | | | NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | | REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | | | PROVIDE DRAWING NOTE INDICATING, "FIRE PROTECTION | | | SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND | | | RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION | | | SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A | | | 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A | | | FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED | | | BY EMAIL ([email protected]) OR IN WRITING (FAX: | | | 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE | | | MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY." | | | | | | SHEET A1.09: MONUMENTAL STAIR SHALL COMPLY WITH SECTION | | | 8.6.8.2 (CONVENIENCE OPENINGS) WHEREBY THE | | | FLOOR-TO-FLOOR OPENING IS REQUIRED TO BE SEPARATED FROM | | | CORRIDORS AND EXIT ACCESS INTO EXISTING EXIT STAIR #1. | | | | | | SHEET A1.21: ELEVATOR LOBBY DOORS ARE EQUIPPED WITH | | | CARD READERS. PER SECTION 7.2.1.6.3, EACH ELEVATOR | | | LANDING AND LOBBY SHALL HAVE ACCESS TO AT LEAST ON | | | EXIT. EXIT ACCESS SHALL NOT REQUIRE THE USE OF A KEY, | | | TOOL, SPECIAL KNOWLEDGE, OR SPECIAL EFFORT. DOORS | | | SEPARATING THE ELEVATOR LOBBY FROM THE EXIT ACCESS | | | SHALL BE PERMITTED TO BE ELECTRONICALLY LOCKED IN | | | ACCORDANCE WITH SECTION 7.2.1.6.3 ELEVATOR LOBBY EXIT | | | ACCESS DOOR ASSEMBLIES LOCKING: DOOR ASSEMBLIES | | | SEPARATING THE ELEVATOR LOBBY FROM THE EXIT ACCESS | | | SHALL BE PERMITTED TO BE ELECTRONICALLY LOCKED, | | | PROVIDED THAT ALL THE FOLLOWING CRITERIA ARE MET: | | | (1) THE ELECTRONIC SWITCH FOR RELEASING THE LOCK IS | | | LISTED IN ACCORDANCE WITH UL 294, STANDARD FOR ACCESS | | | CONTROL SYSTEM UNITS | | | (2) THE BUILDING IS PROTECTED THROUGHOUT BY A FIRE | | | ALARM SYSTEM | | | (3) THE BUILDING IS PROTECTED THROUGHOUT BY AN | | | APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM | | | (4) WATERFLOW IN THE SPRINKLER SYSTEM REQUIRED BY | | | 7.2.1.6.3(3) IS ARRANGED TO INITIATE THE BUILDING FIRE | | | ALARM SYSTEM. | | | (5) THE ELEVATOR LOBBY IS PROTECTED BY AN APPROVED, | | | SUPERVISED SMOKE DETECTION SYSTEM | | | (6) DETECTION OF SMOKE BY THE DETECTION SYSTEM REQUIRED | | | BY 7.2.1.6.3(5) IS ARRANGED TO INITIATE THE BUILDING | | | FIRE ALARM SYSTEM. | | | (7) INITIATION OF THE BUILDING FIRE ALARM SYSTEM BY | | | OTHER THAN MANUAL FIRE ALARM BOXES UNLOCKS THE ELEVATOR | | | LOBBY DOOR ASSEMBLY. | | | (8) LOSS OF POWER TO THE ELEVATOR LOBBY ELECTRONIC LOCK | | | SYSTEM UNLOCKS THE ELEVATOR LOBBY DOOR ASSEMBLIES. | | | (9) THE ELEVATOR LOBBY ELECTRONIC LOCK SYSTEM IS NOT | | | SUPPLIED WITH EMERGENCY OR STANDBY ELECTRICAL POWER. | | | (10) ONCE UNLOCKED, THE ELEVATOR LOBBY DOOR ASSEMBLIES | | | REMAIN UNLOCKED UNTIL THE BUILDING FIRE ALARM SYSTEM | | | HAS BEEN MANUALLY RESET. | | | (11) WHERE THE ELEVATOR LOBBY DOOR ASSEMBLIES REMAIN | | | LATCHED AFTER BEING UNLOCKED, LATCH-RELEASING HARDWARE | | | IS AFFIXED TO THE DOOR LEAVES. | | | (12) A TWO-WAY COMMUNICATION SYSTEM IS PROVIDED FOR | | | COMMUNICATION BETWEEN THE ELEVATOR LOBBY AND A CENTRAL | | | CONTROL POINT THAT IS CONSTANTLY STAFFED. | | | (13) THE CENTRAL CONTROL POINT STAFF REQUIRED BY | | | 7.2.1.6.3(12) IS CAPABLE, TRAINED, AND AUTHORIZED TO | | | PROVIDE EMERGENCY ASSISTANCE. | | | (14) THE PROVISIONS OF DELAYED-EGRESS LOCKING SYSTEMS | | | ARE NOT APPLIED TO THE ELEVATOR LOBBY DOOR ASSEMBLIES. | | | (15) THE PROVISIONS OF ACCESS-CONTROLLED EGRESS DOOR | | | ASSEMBLIES ARE NOT APPLIED TO THE ELEVATOR LOBBY DOOR | | | ASSEMBLIES. | | | | | | SHEET A6.01: PLAN INDICATES WOOD VENEER TO BE APPLIED | | | TO EXISTING STAIR DOORS. EXISTING FIRE RATED STAIR | | | DOORS ARE NOT PERMITTED TO BE ALTERED UNLESS | | | SPECIFICALLY LISTED. | | | | | | FS1.1: PROVIDE ORDINARY HAZARD SPRINKLER DENSITIES FOR | | | 12TH FLOOR STORAGE ROOM AND 14TH FLOOR STORAGE #1418. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-09-08 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-08 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-08-18 |
Time |
08:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-08-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-08-12 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-07-23 |
Time |
09:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-07-14 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-07-14 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-06-13 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-08-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-08-12 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-08-12 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2014-08-12 10:53:51 | HOOD AND COOLERS REQUIRE SEPARATE APPLICATION, PLANS | | | AND PERMIT | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 5614-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-14 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-07-14 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-07-02 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2014-07-14 15:54:32 | PLAN DENIED | | | 1) SEPARATE APPLICATION, PLAN AND PERMIT REQUIRED FOR | | | HOOD | | | AND GREASE DUCT. 107 FBC 2010 | | | 2) PAGE M3.0 12TH. FLOOR MISSING DUCT SIZE. 107 FBC | | | 2010 | | | 3) PAGE M3.2 14TH FL. TWO SEPARATE VAV BOXES SERVING | | | ONE GRILL | | | IN TWO OR MORE LOCATIONS, SIZE RETURN AIR DUCT FROM VAV | | | BOXES | | | 4) PAGE M3.3 SAME AS M3.2 | | | 5) REFER TO SECTION 503.2.4.4 SHUT OFF DAMPER CONTROL | | | 2010 FLORIDA ENERGY CODE | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX-561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-29 |
Time |
06:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-29 |
Time |
05:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-07-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-26 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-26 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2014-07-26 11:06:39 | PLUMBING PLAN REVIEW | | | PERMIT: 14060196 | | | ADD:777 S FLAGLER 12TH FLOOR | | | CONT: WOOLEMS | | | TEL: (561)835-0401 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: SAT. JULY 26/2014 | | | ACTION: DENIED | | | | | | 1) 2ND REQUEST, NOTE THAT THIS SAME QUESTION BEING | | | ASKED THE 2ND TIME UNDER THE BUILDING REVIEW SINCE THE | | | OCCUPANT LOAD COUNT IS NOT FOUND ON THE ARCHITECTURAL | | | PLANS. WHERE THE COMMON RESTROOMS ARE BEING DEMOLISHED | | | AND REBUILT THE PLANS DO NOT HAVE A OCCUPANT LOAD COUNT | | | PER FLOOR NOR DOES P0.1 SHOW COMPLIANCE WITH 2010 | | | FBC-PLUMBING TABLE 403.1. | | | | | | 2) 2ND REQUEST, RESPONSE COMMENT INDICATES THE | | | ACCESIBLE SHOWER DETAIL IS FOUND UNDER SHEET A0.06, NOT | | | THERE EITHER. SHEET P2.2: | | | 2A) THE 2 SINGLE USER BATHROOMS (SHOWER) DO NOT SHOW | | | DIMENSIONS FOR SHOWERS AND COMPLIANCE WITH THE 2010 | | | FBC-ACCESSIBILITY CODE 608.2.1. 36"X36". TRANSFER TYPE | | | SHOWER COMPARTMENTS. | | | | | | 2B) THE 2 SINGLE USER BATHROOMS (SHOWER) DO NOT SHOW | | | DIMENSIONS FOR SHOWERS AND COMPLIANCE WITH THE 2010 | | | FBC-ACCESSIBILITY CODE | | | 608.4 SEATS. A FOLDING OR NON-FOLDING SEAT SHALL BE | | | PROVIDED IN TRANSFER TYPE SHOWER COMPARTMENTS. | | | | | | 2C) COMPLIED> | | | | | | 2D) 2ND REQUEST, THE RESPONCE COMMENT INDICATES SEE | | | SHEET P8.1 DETAIL # 11. NOTE THIS DETAIL SHOWS A GREASE | | | INTERCEPTOR GT 2701-20 OR EQUAL. SUBMIT THE | | | MANUFACTURERS SPECIFICATION SHEETS FOR REVIEW FOR CODE | | | COMPLIANCE | | | . | | | USE OF THE WORD EQUAL SEE 2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. | | | | | | THE OTHER ISSUE WITH THIS DETAIL SHOWS THE USE OF AIR | | | ADMITTANCE VALVES. THE AIR ADMITTANCE VALVES CAN ONLY | | | BE USED: | | | 917.3.1 LOCATION OF BRANCH. | | | THE HORIZONTAL BRANCH DRAIN SHALL CONNECT TO THE | | | DRAINAGE STACK OR BUILDING DRAIN A MAXIMUM OF FOUR | | | BRANCH INTERVALS FROM THE TOP OF THE STACK. | | | 917.3.2 RELIEF VENT. | | | WHERE THE HORIZONTAL BRANCH IS LOCATED MORE THAN FOUR | | | BRANCH INTERVALS FROM THE TOP OF THE STACK, THE | | | HORIZONTAL BRANCH SHALL BE PROVIDED WITH A RELIEF VENT | | | THAT SHALL CONNECT TO A VENT STACK OR STACK VENT, OR | | | EXTEND OUTDOORS TO THE OPEN AIR. THE RELIEF VENT SHALL | | | CONNECT TO THE HORIZONTAL BRANCH DRAIN BETWEEN THE | | | STACK AND THE MOST DOWNSTREAM FIXTURE DRAIN CONNECTED | | | TO THE HORIZONTAL BRANCH DRAIN. THE RELIEF VENT SHALL | | | BE SIZED IN ACCORDANCE WITH SECTION 916.2 AND INSTALLED | | | IN ACCORDANCE WITH SECTION 905. THE RELIEF VENT SHALL | | | BE PERMITTED TO SERVE AS THE VENT FOR OTHER FIXTURES. | | | | | | 2E) COMPLIED. | | | | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-08 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-07 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2014-07-07 16:30:50 | PLUMBING PLAN REVIEW | | | PERMIT: 14060196 | | | ADD:777 S FLAGLER 12TH FLOOR | | | CONT: WOOLEMS | | | TEL: (561)835-0401 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JULY 07/2014 | | | ACTION: DENIED | | | | | | 1) WHERE THE COMMON RESTROOMS ARE BEING DEMOLISHED AND | | | REBUILT THE PLANS DO NOT HAVE A OCCUPANT LOAD COUNT PER | | | FLOOR NOR DOES P0.1 SHOW COMPLIANCE WITH 2010 | | | FBC-PLUMBING TABLE 403.1. | | | | | | 2) SHEET P2.2: | | | 2A) THE 2 SINGLE USER BATHROOMS (SHOWER) DO NOT SHOW | | | DIMENSIONS FOR SHOWERS AND COMPLIANCE WITH THE 2010 | | | FBC-ACCESSIBILITY CODE 608.2.1. 36"X36". TRANSFER TYPE | | | SHOWER COMPARTMENTS. | | | | | | 2B) THE 2 SINGLE USER BATHROOMS (SHOWER) DO NOT SHOW | | | DIMENSIONS FOR SHOWERS AND COMPLIANCE WITH THE 2010 | | | FBC-ACCESSIBILITY CODE | | | 608.4 SEATS. A FOLDING OR NON-FOLDING SEAT SHALL BE | | | PROVIDED IN TRANSFER TYPE SHOWER COMPARTMENTS. | | | | | | 2C) THE 2 SINGLE USER BATHROOMS (SHOWERS) ON THIS SHEET | | | AND P5.1 THE SANITARY ISOMETRIC ARE DRAWN AS A | | | HORIZONTAL WET WENT. HORIZONTAL WET VENTS ARE TO BE | | | USED ONLY IN SINGLE FAMILY RESIDENCE 909.1 AND | | | COMMENTARY & BOAF 2007 INFORMAL INTERPRETATION 6090. | | | THE OTHER ISSUE WITH THE SHOWER FIXTURE ARM IT EXCEEDS | | | THE ALLOWABLE DISTANCE FROM FIXTURE TRAP TO VENT TABLE | | | 906.1. | | | | | | 2D) THE REMODELING OF THE KITCHEN AND SANITARY DRAINAGE | | | THERE IS A COMMERCIAL KITCHEN 3 COMPARTMENT SINK AND NO | | | GREASE INTERCEPTOR. | | | FBC-P 1003.1 WHERE REQUIRED. INTERCEPTORS AND | | | SEPARATORS SHALL BE PROVIDED TO PREVENT THE DISCHARGE | | | OF OIL, GREASE, SAND AND OTHER SUBSTANCES HARMFUL OR | | | HAZARDOUS TO THE BUILDING DRAINAGE SYSTEM, THE PUBLIC | | | SEWER, | | | 003.3.1 GREASE INTERCEPTORS AND AUTOMATIC GREASE | | | REMOVAL DEVICES REQUIRED. | | | A GREASE INTERCEPTOR OR AUTOMATIC GREASE REMOVAL DEVICE | | | SHALL BE REQUIRED TO RECEIVE THE DRAINAGE FROM FIXTURES | | | AND EQUIPMENT WITH GREASE-LADEN WASTE LOCATED IN FOOD | | | PREPARATION AREAS, SUCH AS IN RESTAURANTS, HOTEL | | | KITCHENS, HOSPITALS, SCHOOL KITCHENS, BARS, FACTORY | | | CAFETERIAS AND CLUBS. | | | | | | 2E) PLEASE INDICATE THE EXISTANCE OF A SERVICE SINK | | | INCOMPLIANCE WITH FBC-P TABLE 403.1. | | | | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2014-09-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-17 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-16 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
4 |
Status |
P |
Date |
2014-09-05 |
|
|
Cont ID |
|
| Sent By |
kconrad |
Date |
2014-09-05 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
kconrad |
Date |
2014-09-05 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2014-09-05 09:50:33 | REVIEWED SPECIAL INSPECTOR AGREEMENT: APPROVED AS | | | STATED. |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
3 |
Status |
F |
Date |
2014-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-29 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-29 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2014-08-29 09:24:09 | BUILDING PLAN REVIEW | | | PERMIT: 14060196 | | | ADD:777 S FLAGLER 12TH FLOOR | | | CONT: WOOLEMS | | | TEL: (561)835-0401 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE:FRI. 29/2014 | | | ACTION: DENIED | | | | | | 4B) THRESHOLD INSPECTOR: | | | WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES | | | DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL | | | INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA | | | STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS | | | CODE. A THRESHOLD AGREEMENT WILL NEED TO BE SIGNED BY | | | ALL PARTIES, PLEASE PROVIDE A E-MAIL ADDRESS THAT WE | | | CAN SEND ALL THE REQUIRED DOCUMENTS. | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
F |
Date |
2014-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-29 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-29 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2014-08-29 09:23:41 | BUILDING PLAN REVIEW | | | PERMIT: 14060196 | | | ADD:777 S FLAGLER 12TH FLOOR | | | CONT: WOOLEMS | | | TEL: (561)835-0401 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE:FRI. 29/2014 | | | ACTION: DENIED | | | | | | 4B) THRESHOLD INSPECTOR: | | | WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES | | | DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL | | | INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA | | | STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS | | | CODE. A THRESHOLD AGREEMENT WILL NEED TO BE SIGNED BY | | | ALL PARTIES, PLEASE PROVIDE A E-MAIL ADDRESS THAT WE | | | CAN SEND ALL THE REQUIRED DOCUMENTS. | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2014-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-29 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-29 |
Time |
06:25 |
Sent To |
|
|
| Notes |
| 2014-08-29 09:19:51 | BUILDING PLAN REVIEW | | | PERMIT: 14060196 | | | ADD:777 S FLAGLER 12TH FLOOR | | | CONT: WOOLEMS | | | TEL: (561)835-0401 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE:FRI. 29/2014 | | | ACTION: DENIED | | | | | | 4B) THRESHOLD INSPECTOR: | | | WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES | | | DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL | | | INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA | | | STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS | | | CODE. A THRESHOLD AGREEMENT WILL NEED TO BE SIGNED BY | | | ALL PARTIES, PLEASE PROVIDE A E-MAIL ADDRESS THAT WE | | | CAN SEND ALL THE REQUIRED DOCUMENTS. | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-06-25 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2014-06-25 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2014-06-25 |
Time |
11:30 |
Sent To |
|
|
| Notes |
|
|
|