| 2014-06-04 13:14:13 | FUEL GAS PROVISO: |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH |
| | THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, |
| | BUILDING. |
| | R315.1 CARBON MONOXIDE PROTECTION. |
| | EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING |
| | BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION |
| | IS ISSUED AND HAVING A FOSSIL-FUEL-BURNING HEATER OR |
| | APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE, OR OTHER |
| | FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE |
| | AS A BYPRODUCT OF COMBUSTION SHALL HAVE AN |
| | OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN 10 |
| | FEET OF EACH ROOM USED FOR SLEEPING PURPOSES. |
| | EXCEPTION: THIS SECTION SHALL NOT APPLY TO EXISTING |
| | BUILDINGS THAT ARE UNDERGOING ALTERATIONS OR REPAIR |
| | UNLESS THE ALTERATION IS AN ADDITION AS DEFINED IN |
| | SECTION R315.1.3. |
| | R315.1.1 CARBON MONOXIDE ALARM. |
| | THE REQUIREMENTS OF SECTION R315.1 SHALL BE SATISFIED |
| | BY PROVIDING FOR ONE OF THE FOLLOWING ALARM |
| | INSTALLATIONS: |
| | (1) A HARD-WIRED CARBON MONOXIDE ALARM. |
| | (2) A BATTERY-POWERED CARBON MONOXIDE ALARM. |
| | (3) A HARD-WIRED COMBINATION CARBON MONOXIDE AND SMOKE |
| | ALARM. |
| | (4) A BATTERY-POWERED COMBINATION CARBON MONOXIDE AND |
| | SMOKE ALARM. |
| | |