Plan Review Details - Permit 14060093
Plan Review Stops For Permit 14060093
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-07-17 Cont ID  
Sent By jwitmer Date 2014-07-17 Time 10:50 Rev Time 0.00
Received By jwitmer Date 2014-07-17 Time 10:50 Sent To  
Notes
2014-07-17 10:50:51BUILDING PROVISO:
 PB OUTLET MALLS:
 A LETTER FROM THE QUALIFIER OF BOTH THE SHELL
 CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT
 CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT
 PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT
 CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK
 HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY
 WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE
 DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-06-04 Cont ID  
Sent By jwitmer Date 2014-06-04 Time 17:33 Rev Time 0.00
Received By jwitmer Date 2014-06-04 Time 16:25 Sent To  
Notes
2014-06-04 17:33:44BUILDING PROVISO:
 PB OUTLET MALLS:
 A LETTER FROM THE QUALIFIER OF BOTH THE SHELL
 CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT
 CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT
 PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT
 CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK
 HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY
 WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE
 DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-07-01 Cont ID  
Sent By dhayes Date 2014-07-01 Time 12:37 Rev Time 0.00
Received By dhayes Date 2014-07-01 Time 12:37 Sent To  
Notes
2014-07-01 13:00:12DATE: 7/1/2014
 PROJECT: THE VITAMIN SHOPPE
 PERMIT#: 14060093
 CODE: 2008 EDITION OF THE NEC
 2010 EDITION OF THE FBC
 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
  
 1ST ELECTRICAL PLAN REVIEW
 ACTION:PROVISO
  
 1) THE INTERIOR OF AN UNDERGROUND RACEWAY SHALL BE
 CONSIDERED A WET LOCATION. ALL CONDUCTORS WITHIN THE
 RACEWAY SHALL BE LISTED ACCORDINGLY. SUITABILITY FOR
 INSTALLATION AND USE IN CONFORMITY WITH THE PROVISIONS
 OF THIS CODE. NEC 110.3(A)(1 THRU 8)
  
 2) A SEPARATE ELECTRICAL PERMIT APPLICATION SHALL BE
 SUBMITTED ACCOMPANIED BY SHOP DRAWINGS, EQUIPMENT
 SUBMITTALS, PRODUCT APPROVALS FOR ALL OF THE FOLLOWING:
 NETWORK, DATA/COM, FIRE ALARM, SECURITY, CCTV, AND
 AUDIO/ VIDEO WORK.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-06-09 Cont ID  
Sent By pleduc Date 2014-06-09 Time   Rev Time 0.00
Received By pleduc Date 2014-06-05 Time 16:36 Sent To  
Notes
2014-06-06 10:46:45THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENT:
  
 NOTICE IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR
 ANY MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR
 MORE WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED
 WITH AN APPROVED SYMBOL. THE APPROVED SYMBOL SHALL BE
 PLACED WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY
 DOOR.
  
 A KNOX BOX AND KEY SYSTEM IS REQUIRED FOR THIS BUILDING
 FOR ENTRY BY FIRE PERSONNEL IN THE EVENT OF AN
 EMERGENCY AT ANY TIME.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-07-17 Cont ID  
Sent By jwitmer Date 2014-07-17 Time 09:41 Rev Time 0.00
Received By jwitmer Date 2014-07-17 Time 07:46 Sent To  
Notes
2014-07-17 07:47:047/17 TO JW DESK (NEEDS RESTAMP)
  
2014-07-03 09:29:00INCOMING SENT TO ZONING BOX . JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-07-01 Cont ID  
Sent By dhayes Date 2014-07-01 Time 13:00 Rev Time 0.00
Received By dhayes Date 2014-06-03 Time 17:56 Sent To  
Notes
2014-06-03 17:57:23B02

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-06-27 Cont ID  
Sent By jwitmer Date 2014-06-27 Time 07:30 Rev Time 0.00
Received By jwitmer Date 2014-06-27 Time 07:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-06-24 Cont ID  
Sent By jsaez Date 2014-06-19 Time 14:51 Rev Time 0.00
Received By jsaez Date 2014-06-19 Time 14:39 Sent To  
Notes
2014-06-19 14:44:331. PROVIDE ON MECHANICAL DWGS. HVAC DESIGN
 REQUIREMENTS, FBC 2010 SECTION 107.

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-06-04 Cont ID  
Sent By jwitmer Date 2014-06-04 Time 17:20 Rev Time 0.00
Received By jwitmer Date 2014-06-04 Time 16:25 Sent To  
Notes
2014-06-04 17:08:33PLUMBING PROVISO:
 SHEET P1& P2 INDICATE THE USE OF FLOOR DRAINS IN THE
 RESTROOMS. THE PLUMBING FIXTURE SPECIFICATIONS, C FLOOR
 DRAINS ZURN 415 DOES NOT INDICATE THE USE OF A TRAP
 PRIMER AS REQUIRED BY THE 2010 FBC-PLUMBING CODE 1002.4
 TRAP SEALS.
 EACH FIXTURE TRAP SHALL HAVE A LIQUID SEAL OF NOT LESS
 THAN 2 INCHES (51 MM) AND NOT MORE THAN 4 INCHES (102
 MM), OR DEEPER FOR SPECIAL DESIGNS RELATING TO
 ACCESSIBLE FIXTURES. WHERE A TRAP SEAL IS SUBJECT TO
 LOSS BY EVAPORATION, A TRAP SEAL PRIMER VALVE SHALL BE
 INSTALLED. TRAP SEAL PRIMER VALVES SHALL CONNECT TO THE
 TRAP AT A POINT ABOVE THE LEVEL OF THE TRAP SEAL. A
 TRAP SEAL PRIMER VALVE SHALL CONFORM TO ASSE 1018 OR
 ASSE 1044.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop POLICE POLICE
Rev No 1 Status N Date 2014-06-13 Cont ID  
Sent By eschneid Date 2014-06-13 Time 14:25 Rev Time 0.00
Received By eschneid Date   Time   Sent To  
Notes
2014-06-13 14:25:45CRIME PREVENTION THROUGH ENVIRONMENTAL DESIGN
 THE CITY OF WEST PALM BEACH HAS RECOGNIZED THAT
 TRADITIONAL CRIME PREVENTION STRATEGIES ARE NOT ENOUGH
 IN TODAY'S SOCIETY AND A NEW APPROACH IS NEEDED. THE
 NAME OF THIS APPROACH IS CRIME PREVENTION THROUGH
 ENVIRONMENTAL DESIGN (CPTED). CPTED ACKNOWLEDGES THE
 MANNER IN WHICH PHYSICAL SPACE IS DESIGNED OR USED HAS
 A DIRECT BEARING ON CRIME AND SECURITY.
 THE PHYSICAL ENVIRONMENT HAS A DRAMATIC EFFECT ON OUR
 OWN BEHAVIOR AND THE WAY IN WHICH WE VIEW THE BEHAVIOR
 OF OTHERS. CPTED IS A CONCEPT SUPPORTED BY A SERIES OF
 OVERLAPPING PRINCIPLES BASED ON THE RELATIONSHIP OF THE
 BUILT ENVIRONMENT TO THE PRESENCE OR ABSENCE OF
 UNDESIRABLE BEHAVIOR. THE CPTED CONCEPT IS: "THE PROPER
 DESIGN AND EFFECTIVE USE OF THE BUILT ENVIRONMENT CAN
 LEAD TO A REDUCTION IN THE INCIDENCE AND FEAR OF CRIME
 AND IMPROVEMENT IN THE QUALITY OF LIFE BY INCORPORATING
 ACCESS CONTROL, NATURAL SURVEILLANCE AND TERRITORIAL
 DEFENSIVE TACTICS.?
 CPTED THEORY IS BASED UPON THE CONTENTION THAT
 PLANNERS, DESIGNERS, ARCHITECTS, LANDSCAPERS AND LAW
 ENFORCEMENT CAN COOPERATIVELY CREATE A 'SAFE' CLIMATE
 WITHIN A BUILT ENVIRONMENT" RIGHT FROM THE BEGINNING.
 SAFETY STRIKES AT THE VERY CORE OF WHAT IS GENERALLY
 REFERRED TO IN A COMMUNITY AS "QUALITY OF LIFE." A SAFE
 ENVIRONMENT IS ONE THAT REGULAR USERS PERCEIVE AS SAFE
 AND NON-USERS (CRIMINALS) PERCEIVE AS HIGHLY RISKY TO
 FREQUENT AND IN WHICH TO COMMIT CRIMES.
 THE WEST PALM BEACH POLICE DEPARTMENT HAS OUTLINED
 GUIDELINES WE WOULD LIKE TO SEE FOLLOWED. IN ADDITION
 TO THE GUIDELINES, WE ENCOURAGE YOU TO PLEASE ADOPT
 THESE MINIMUM STANDARDS:
  
 (1) A FULLY FUNCTIONING AND OPERATIONAL CCTV SYSTEM
 CAPABLE OF RECORDING AND RETRIEVING ON SITE, AN
 IDENTIFIABLE IMAGE TO ASSIST IN OFFENDER IDENTIFICATION
 AND APPREHENSION. MONITORS FOR THE SYSTEM SHOULD BE
 PLACED IN A MANAGER'S OFFICE OR BACK ROOM, WITH A
 MONITOR IN PUBLIC VIEW FROM THE SALES FLOOR.
 (2) CAMERA COVERAGE SHOULD BE AT SENSITIVE LOCATIONS:
 (A) DOORS THAT LEADS TO THE BACK OF HOUSE (B) HALLWAYS
 THAT LEAD TO REAR EXITS (C) SALES FLOOR (D) REGISTERS
 (LOW FOR FACIAL RECOGNITION) (E) FRONT ENTRY.
 (3) DOOR THAT LEADS TO THE BACK OF HOUSE AND EXITING
 REAR DOORS SHOULD BE ALARMED WITH A SENSOR AND VIEW
 FINDER.
 (4) SILENT PANIC ALARM UNDER EACH REGISTER, ONE IN THE
 BACK OF HOUSE WORK AREA
 (5) A SECURED DROP SAFE OR CASH MANAGEMENT DEVICE FOR
 RESTRICTED ACCESS TO MONEY/CASH RECEIPTS AT THE
 REGISTER AND A SECURED DROP SAFE OR CASH MANAGEMENT
 DEVICE IN THE STORAGE AREA.
 (6) CASH OUT AREA SHOULD BE IN THE FRONT OF THE STORE,
 CLOSE TO THE ENTRANCE.
 (7) SECURE THE REGISTERS TO THE COUNTER.
 (8) INSTALL ANTI-THEFT DEVICES INCLUDING SECURITY
 TOWERS AT ENTRANCES.
 (9) USE CONVEX MIRRORS IN CORNERS AND ANTI-THEFT TAGS
 ON MERCHANDISE.
 (10) HEIGHT MARKERS AT THE ENTRANCE AND EXIT.
 (11) EMPLOYEE ACCESS CONTROL ON ALL DOORS THAT LEAD
 INTO THE BACK.
 (12) WHERE WINDOW(S) ARE PRESENT, A CLEAR AND
 UNOBSTRUCTED VIEW FROM OUTSIDE THE STORE AND IN A
 NORMAL LINE OF SIGHT OF THE CASH REGISTER AND SALES
 TRANSACTION AREA
 (13) IF INSTALLING SWING GATE AT REGISTERS THEY SHOULD
 HAVE SIMPLE ACCESS CONTROL.
 (14) ALL SHOWCASES SHOULD HAVE LOCKS AND IN THE
 EXPENSIVE SHOWCASES, CONSIDER AN ALARM.
 (15) INTERIOR SHELVING AND DISPLAYS SHOULD BE NO HIGHER
 THAN FIVE FEET, EVEN LESS IN FRONT OF WINDOWS.
  
  
 OFFICER K. TUCKER-CARSILLO
 CRIME PREVENTION UNIT
 WEST PALM BEACH POLICE DEPT
 600 BANYAN BLVD
 WEST PALM BEACH, FL 33401
 (561) 822-1620 OFFICE
 (561) 822-1648 FAX
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2014-07-16 Cont ID  
Sent By eschneid Date 2014-07-16 Time 09:05 Rev Time 0.00
Received By eschneid Date 2014-07-16 Time 09:05 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2014-06-13 Cont ID  
Sent By eschneid Date 2014-06-13 Time 14:23 Rev Time 0.00
Received By eschneid Date 2014-06-13 Time 14:23 Sent To  
Notes
2014-06-13 14:24:49FAILED
  
 PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) THE PALM BEACH OUTLETS MANAGEMENT APPROVAL STAMP IS
 REQUIRED ON THE PLANS.
  
 2) PLEASE EXPLAIN WHY THE SHELL PERMIT FOR BAY E01
 SHOWS 3,000 SQ. FT. YET THIS PERMIT IS FOR A SPACE
 3,002 SQ. FT.? IF THE SPACE IS INCREASING, THEN
 CONSTRUCTION DRAWINGS FOR THE EXPANDED SPACE SHALL BE
 PROVIDED.
  
 3) DESCRIBE WHAT THE ?INTERIOR APPLIED OPAQUE WINDOW
 VINYLS? ON THE PALM BEACH LAKES BOULEVARD WINDOWS ARE.
 PLEASE BE AWARE THAT THE PALM BEACH OUTLETS REQUIRE
 VISIBILITY INTO THE STORE, SO THE WINDOWS MAY NOT BE
 BLOCKED.
  
 4) THE FLOOR PLAN SHOWS A DISPLAY AREA BEHIND THE
 WINDOWS THAT WOULD BE BLOCKED BY OPAQUE WINDOW VINYLS.
 WHAT WILL BE PLACED IN THE DISPLAY AREA ONCE THE WINDOW
 VINYLS ARE REMOVED?
  
 5) AWNINGS REQUIRE SEPARATE PERMITS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  
2014-06-06 11:16:346/5/14