Plan Review Details - Permit 14051087
Plan Review Stops For Permit 14051087
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-06-25 Cont ID  
Sent By skennedy Date 2014-06-25 Time 08:16 Rev Time 0.00
Received By skennedy Date 2014-06-25 Time 08:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date   Cont ID  
Sent By dhayes Date   Time 12:25 Rev Time 0.00
Received By dhayes Date   Time 15:44 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-06-03 Cont ID  
Sent By pleduc Date 2014-06-03 Time   Rev Time 0.00
Received By pleduc Date 2014-06-03 Time 13:35 Sent To B
Notes
2014-06-03 13:51:53THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THIS PLAN IS APPROVED PENDING THE APPROVAL OF BUILDING
 AND ELECTRICAL REVIEWS.
  
 THIS APPROVAL DOES NOT CONSTITUTE APPROVAL OF THE
 SEATING, BUFFET AND EQUIPMENT PLAN.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
 PROVIDE TYPE K EXTINGUISHERS WHEN COOKING WITH GREASE
 OR WHEN PRODUCING SMOKE OR GREASE-LADEN VAPORS.
  
 TENTS SHALL BE LOCATED AT LEAST 10 FEET AWAY FROM
 BUILDING STRUCTURES.
  
 TENT SHALL BE OF THE OPEN AREA/NO SIDEWALL TYPE,
 OTHERWISE EMERGENCY LIGHTING AND ILLUMINATED EXIT SIGNS
 ARE REQUIRED FOR TENTS EXCEEDING 1,200 SQUARE FEET.
  
 POST WEATHERPROOF NO SMOKING SIGNS IN CONSPICUOUS
 LOCATIONS.
  
 GENERATORS AND OTHER INTERNAL COMBUSTION POWER SOURCES
 SHALL BE SEPARATED FROM TENTS BY A MINIMUM OF 5 FEET
 AND SHALL BE PROTECTED FROM CONTACT BY FENCING OR
 ENCLOSURE.
  
  
2014-05-30 10:37:21ROUTED TO FIRE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-06-25 Cont ID  
Sent By skennedy Date 2014-06-25 Time 08:16 Rev Time  
Received By skennedy Date   Time   Sent To  
Notes
***NONE***