Plan Review Details - Permit 14051067
| Plan Review Stops For Permit 14051067 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-02 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-09-02 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2014-09-02 16:39:34 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. FBC 1609, WIND DESIGN CRITERIA WAS STATED AS | | | V=115MPH, HIGH VELOCITY HURRICANE ZONE. | | | | | | PLEASE REVISE. ONLY BROWARD AND DADE COUNTIES ARE | | | LOCATED IN THE HVHZ. PALM BEACH MINIMUM DESIGN CRITERIA | | | FOR THE COLUMNS (STRUCTURES) WOULD BE 150MPH, VULT | | | (RISK CATEGORY I). THERE IS NO WIND DESIGN CRITERIA FOR | | | FENCES IN NON-HVHZ. MY APOLOGIES FOR MY PREVIOUS | | | COMMENT NOT BEING CLEAR THAT IT PERTAINED ONLY TO THE | | | COLUMNS. | | | | | | IF THIS PROJECT IS TIME SENSITIVE, NEXT REVIEW WILL BE | | | EXPEDITED (NO FEE) UPON REQUEST DUE TO THE AMBIGUITY OF | | | THE PREVIOUS COMMENT. PLEASE REQUEST VIA EMAIL. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-06-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-06-04 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-06-04 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2014-06-04 14:49:38 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | | FS481. | | | | | | 2. REIVSE PLAN TO INCLUDE WIND DESIGN CRITERIA FBC | | | 1603.1.4. | | | | | | 3. PROVIDE A STRUCTURAL DETAIL FOR THE COLUMNS, FBC | | | 107, 1609. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-02 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-08-22 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2014-08-25 08:50:40 | RE-SUBMITTAL SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-06-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-06-04 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-06-04 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2014-05-29 15:42:51 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-06-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-06-02 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-06-02 |
Time |
14:53 |
Sent To |
B |
|
| Notes |
| 2014-05-30 11:58:05 | 5/30/14 ZONING SENT TO FM SG |
|
|
|
Account Summary | Usage Policy | Privacy Policy