| Plan Review Stops For Permit 14050989 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-06-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-27 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-27 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-13 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-13 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2014-06-13 15:00:43 | BUILDING PLAN REVIEW | | | PERMIT: 14050989 | | | ADD: 207 6TH ST | | | CONT: FINE LINE CONSTRUCTION | | | TEL: (561)582-7880 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. JUNE 13/2014 | | | ACTION: DENIED | | | | | | 1) PLEASE PROVIDE A SURVEY OF THE PROPERTY, THE SITE | | | PLAN DOES NOT MATCH TTHE LOT CONFIGURATION FOUND WITH | | | THE PROPERTY APPRAISERS WEB SITE. | | | THE SECOND ISSUE IS TO DETERMINE IF THIS BUILDING IS IN | | | A A5 FLOOD ZONE. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. IF FLOOD ZONE THEN FLOOD ZONE CERTIFICATES | | | WILL BE REQUIRED AND THE FLOOR ELEVATION OF THE 1ST | | | FLOOR. | | | | | | 2) SHEET A-1.0: | | | 2A) BOTH THE MENS(125) & WOMENS (126) RESTROOMS HAVE | | | WITHIN THEM ACCESSIBLE TOLIET COMPARTMENTS (STALLS) | | | PLEASE SEE 2010 FBC-ACCESSIBLITY CODE SECTION 604.8.1.2 | | | FOR DOOR SWING. TOILET COMPARTMENT DOORS SHALL NOT | | | SWING INTO THE MINIMUM REQUIRED COMPARTMENT AREA. THE | | | DOORS SWING IN OVER THE REQUIED CLEAR AREA FOR THE LAV. | | | | | | 2B) NO ACTION TO BE TAKEN. THE PLANS DO NOT PROVIDE | | | VERTICAL ACCESSIBILITY TO THE MEZZANINE AREA. 201.1.1, | | | IT APPEARS THE EXCEPTIONS , EXCEPTION # 2 FOR STORAGE | | | AND EXCEPTION # 3 FOR OCCUPIABLE SPACES AND PRIVATE | | | OFFICE. | | | | | | 3) SHEET S-4.1 SHOWS THE DESIGN LOADS BUT THERE ARE NO | | | DESIGN LOADS FOR THE STAIRS OR MEZZANINE FOR THE OFFICE | | | OR THE STORAGE PORTION OF THE MEZZANINE, WILL THE | | | MEZZANINE BEDESIGNED FOR LIGHT OR HEAVY? FBC-B TABLE | | | 1607.1. | | | | | | 4) PLANS DO NOT SHOW CODE COMPLIANCE WITH 2010 FL | | | ACCESSIBILTY 211.2 MINIMUM NUMBER. | | | NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. | | | ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH | | | 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH | | | 602.7. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | NOTE NO ROOFING PRODUCT APPROVALS WERE SUBMITTED. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-06-26 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-06-26 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-26 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2014-06-26 07:37:42 | BACK TO C01 FOR ADDITIONAL REVIEWS. | | 2014-06-23 11:03:51 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-06-09 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-06-09 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-09 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2014-06-09 16:24:56 | 6/9/14. | | | PROJECT: HOPKINS MARINE. | | | PERMIT#: 14050989 | | | CODE: 2008 EDITION OF THE NEC AND THE 2010 EDITION OF | | | THE FBC | | | ACTION: APPROVED WITH PROVISO: | | | | | | 1) PARTITIONS OF THE FREESTANDING TYPE (NOT FIXED) | | | SHALL BE PERMITTED TO BE CONNECTED TO THE BUILDING | | | ELECTRICAL SYSTEM BY ONE OF THE WIRING METHODS OF | | | CHAPTER 3. MULTIWIRE BRANCH CIRCUITS SUPPLYING POWER TO | | | PERMANENTLY CONNECTED FREESTANDING PARTITIONS SHALL BE | | | PROVIDED WITH A MEANS TO DISCONNECT SIMULTANEOUSLY ALL | | | UNGROUNDED CONDUCTORS AT THE PANELBOARD WHERE THE | | | BRANCH CIRCUIT ORIGINATES. NEC 605.7 | | | | | | 2) EACH MULTIWIRE BRANCH CIRCUIT SHALL BE PROVIDED WITH | | | A MEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL | | | UNGROUNDED CONDUCTORS AT THE POINT WHERE THE BRANCH | | | CIRCUIT ORIGINATES. 210.4(B) | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR AT [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-06-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-06-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-06-30 |
Time |
10:56 |
Sent To |
PC |
|
| Notes |
| 2014-06-23 11:05:17 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-06-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-06-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-06-04 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-06-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-06-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-06-19 |
Time |
11:05 |
Sent To |
PC |
|
| Notes |
| 2014-06-23 11:06:18 | RESUBMITTAL SENT TO C1 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-13 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-28 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2014-05-29 11:06:51 | INCOMING SENT TO C01 . JW |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2014-06-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-06-26 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-06-26 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2014-06-23 11:06:43 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-06-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-06-06 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-06-06 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2014-06-06 15:39:20 | PASS PROVISO | | | 1) REFER TO SECTION 503.2.4.4 SHUTOFF DAMPER CONTROLS | | | 2010 FLORIDA ENERGY CODE | | | 2) PROVIDE A DETAIL FROM THE ENGINEER ON WHAT TYPE | | | ANCHOR AND SIZE ANCHOR USED FOR ANCHORING CURB TO ROOF | | | AND RTU TO CURB AT FIRST INSPECTION. | | | PER SECTION 301.12 WIND RESISTANCE 2010 FBC (M) | | | 3) PROVIDE A DETAIL SHOWING THE TYPE AND SIZE ANCHOR | | | USED FOR CONDENSER STAND TO ROOF. PER SECTION 301.12 | | | WIND RESISTANCE. 2010 FBC (M) AT FIRST INSPECTION | | | PLAN REVIEW BY HAROLD MOSER | | | HMOSER @WPB.ORG | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-06-18 |
|
|
Cont ID |
|
| Sent By |
jsaez |
Date |
2014-06-05 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-06-06 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2014-06-05 10:17:23 | 1. INDICATE ON DWGS. FIRE-DAMPERS ON ALL SUPPLY, ROUND | | | SHEETMETAL DUCTWORK PENETRATIONS THRU FLOOR. | | | 2. PROVIDE FIRE- DAMPER DETAIL |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-06-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-27 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-27 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-13 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-13 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2014-06-13 15:15:41 | PLUMBING PLAN REVIEW | | | PERMIT: 14050989 | | | ADD: 207 6TH ST | | | CONT: FINE LINE CONSTRUCTION | | | TEL: (561)582-7880 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. JUNE 13/2014 | | | ACTION: DENIED | | | | | | 1) THE SANITARY ISOMETRIC IS DRAWN WITH THE RESTROOMS | | | USING HORIZONTAL WET VENTS. PLEASE SEE THE CODE SECTION | | | INDICATES WET VENTS ARE TO BE INSTALLED IN BATHROOMS (1 | | | & 2 FAMILY) ALSO SEE BOAF INFORMAL INTERPRETATION. | | | | | | DATE: MON APR 13 2009 | | | REPORT: 6090 | | | CODE: PLUMBING CODE YEAR: 2007 | | | SECTION: 909 | | | QUESTION: | | | IS IT THE INTENT OF THE FLORIDA BUILDING CODE - | | | PLUMBING SECTION 909 TO ALLOW A URINAL TO WET VENT A | | | SINGLE COMMERCIAL | | | WATER CLOSET OR TO DRAIN INTO THAT WATER CLOSET?S | | | INDIVIDUAL VENT? | | | COMMENT: | | | ANSWER: | | | NO. ONLY FIXTURES IN BATHROOM GROUPS AS DEFINED IN | | | FLORIDA BUILDING CODE - PLUMBING CHAPTER 2 ARE | | | PERMITTED TO | | | CONNECT TO THE WET VENT. ANY ADDITIONAL FIXTURES MUST | | | DISCHARGE DOWNSTREAM OF THE WET VENT. | | | COMMENTARY: | | | A URINAL IS NOT INCLUDED IN THE DEFINITION OF A | | | BATHROOM GROUP. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-06-26 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2014-06-26 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2014-06-26 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2014-06-26 16:08:22 | PROVISO: 1. PERMIT FOR SURFACE PARKING LOT, LANDSCAPE | | | AND IRRIGATION SHALL BE SUBMITTED, APPROVED, AND WORK | | | COMPLETED BEFORE FINAL CO FOR BUILDING. | | | 2. LIGHTING PLAN FOR SURFACE PARKING SHALL BE | | | SUBMITTED. | | | 3. AWNING NOT INCLUDED WITH THIS PERMIT. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-06-12 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2014-06-12 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2014-06-12 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2014-06-12 16:35:07 | 1. ADDITIONAL WORK SHALL BE DONE WITH THE PARKING | | | LAYOUT TO MAKE THE PARKING AREA IN COMPLIANCE WITH THE | | | REGULATIONS AS MUCH AS POSSIBLE. THE PROPOSED LAYOUT IS | | | NOT ACCEPTABLE. | | | 2. LANDSCAPE AND IRRIGATION DRAWINGS SHALL BE | | | SUBMITTED. | | | 3. WINDOW ON EAST SIDE OF MAIN ENTRANCE DOOR SHALL | | | INCLUDE APPLIED HORIZONTAL MULLS AS THE ORIGINAL | | | OPENING, AS DISCUSSED WITH THE HISTORIC PRESERVATION | | | PLANNER. | | | 4. PROPOSED AWNING ON NORTH ELEVATION IS NOT CONSISTENT | | | WITH THE BUILDING DESIGN. | | | 5. PLEASE PROVIDE A SURVEY OF THE PROPERTY. | | | 6. PLEASE INCLUDE LIGHTING PROPOSAL FOR PARKING LOT. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. | | 2014-06-05 16:41:24 | 6/5/14 |
|
|