Plan Review Details - Permit 14050974
| Plan Review Stops For Permit 14050974 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-07-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-17 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-17 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2014-07-17 11:54:05 | BUILDING PLAN REVIEW | | | PERMIT: 14050974 | | | ADD: 525 S FLAGLER DR # GPH3 | | | CONT: CAMBRIDGE CONSTRUCTION | | | TEL: (561)284-3722 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: THURSDAY JULY17/2014 | | | ACTION: | | | | | | BUILDING PROVISO: | | | 1A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | 1B) FBC-B 2010 603.2 EXCEPTION (1) TILE FLOORING | | | FLOOR INSULATION PLACED BETWEEN TWO LAYERS OF | | | NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING | | | AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX | | | OF NOT MORE THAN 100. | | | | | | 1C) FBC-B 2010 603.2 EXCEPTION 2 WOOD FLOORS | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 703.4 NONCOMBUSTIBILITY TESTS. | | | THE TESTS INDICATED IN SECTIONS 703.4.1 AND 703.4.2 | | | SHALL SERVE AS CRITERIA FOR ACCEPTANCE OF BUILDING | | | MATERIALS AS SET FORTH IN SECTIONS 602.2, 602.3 AND | | | 602.4 IN TYPE I, II, III AND IV CONSTRUCTION. THE TERM | | | ?NONCOMBUSTIBLE? DOES NOT APPLY TO THE FLAME SPREAD | | | CHARACTERISTICS OF INTERIOR FINISH OR TRIM MATERIALS. A | | | MATERIAL SHALL NOT BE CLASSIFIED AS A NONCOMBUSTIBLE | | | BUILDING CONSTRUCTION MATERIAL IF IT IS SUBJECT TO AN | | | INCREASE IN COMBUSTIBILITY OR FLAME SPREAD BEYOND THE | | | LIMITATIONS HEREIN ESTABLISHED THROUGH THE EFFECTS OF | | | AGE, MOISTURE OR OTHER ATMOSPHERIC CONDITIONS. | | | | | | 703.4.1 ELEMENTARY MATERIALS. | | | MATERIALS REQUIRED TO BE NONCOMBUSTIBLE SHALL BE TESTED | | | IN ACCORDANCE WITH ASTM E 136. | | | | | | 703.4.2 COMPOSITE MATERIALS. | | | MATERIALS HAVING A STRUCTURAL BASE OF NONCOMBUSTIBLE | | | MATERIAL AS DETERMINED IN ACCORDANCE WITH SECTION | | | 703.4.1 WITH A SURFACING NOT MORE THAN 0.125 INCH (3.18 | | | MM) THICK THAT HAS A FLAME SPREAD INDEX NOT GREATER | | | THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL | | | 723 SHALL BE ACCEPTABLE AS NONCOMBUSTIBLE MATERIALS | | | | | | FBC-B 2010 | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-08 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-08 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-06-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-05 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-05 |
Time |
18:39 |
Sent To |
|
|
| Notes |
| 2014-06-05 18:59:41 | BUILDING PLAN REVIEW | | | PERMIT: 14050974 | | | ADD: 525 S FLAGLER DR # GPH3 | | | CONT: CAMBRIDGE CONSTRUCTION | | | TEL: (561)284-3722 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURSDAY JUNE 05/2014 | | | ACTION: DENIED | | | | | | 1) PLANS SEALED BY OUT OF STATE ARCHITECT. FLORIDA | | | ADMINISTRATIVE RULE 61G1-16.002 DESCRIPTION OF SEAL. | | | (1) THE SEAL SHALL CONTAIN THE NAME OF ONLY ONE | | | ARCHITECT OR INTERIOR DESIGNER AND THE REGISTRATION | | | NUMBER; THE SEAL OF THE ARCHITECT SHALL BE CIRCULAR, | | | AND THE SEAL OF THE INTERIOR DESIGNER SHALL BE | | | HEXAGONAL. BOTH SEALS SHALL BE APPROXIMATELY 2" IN | | | DIAMETER WITH TWO CIRCULAR LINES BETWEEN WHICH LINES | | | SHALL APPEAR, AT THE TOP, THE WORDS ?STATE OF FLORIDA? | | | AND AT THE BOTTOM THE WORDS ?REGISTERED ARCHITECT? OR | | | ?LICENSED INTERIOR DESIGNER,? WHICHEVER IS APPLICABLE. | | | (2) ANY INDIVIDUAL WHO IS BOTH A REGISTERED ARCHITECT | | | AND A LICENSED INTERIOR DESIGNER MUST USE A SEAL WHICH | | | CONTAINS BOTH THE ARCHITECT AND INTERIOR DESIGN | | | REGISTRATION NUMBERS, IN SUCH A MANNER: | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-07-10 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-10 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-10 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2014-07-10 16:57:03 | DATE: 7/9/2014 | | | PROJECT: DREYFOSS RESIDENCE | | | PERMIT#: 14050974 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) AN ELECTRICAL PERMIT IS REQUIRED. THE WRITTEN SCOPE | | | OF WORK DOES NOT CALL OUT SPECIFIC ELECTRICAL WORK | | | HOWEVER THE CODE REQUIRES ELECTRICAL WORK. SEE BELOW: | | | | | | 2) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL | | | 314.3.1 | | | | | | 3) AT LEAST ONE 20-AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH | | | CIRCUITS SHALL HAVE NO OTHER OUTLETS.PROVIDE A 20 | | | AMPERE BRANCH CIRCUIT FOR THE BATHROOM. NEC 210.11 | | | (C)(3) | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-06-10 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-06-10 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-10 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2014-07-10 16:57:42 | DATE: 7/9/2014 | | | PROJECT: DREYFOSS RESIDENCE | | | PERMIT#: 14050974 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) AN ELECTRICAL PERMIT IS REQUIRED. THE WRITTEN SCOPE | | | OF WORK DOES NOT CALL OUT SPECIFIC ELECTRICAL WORK | | | HOWEVER THE CODE REQUIRES ELECTRICAL WORK. SEE BELOW: | | | | | | 2) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL | | | 314.3.1 | | | | | | 3) AT LEAST ONE 20-AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH | | | CIRCUITS SHALL HAVE NO OTHER OUTLETS.PROVIDE A 20 | | | AMPERE BRANCH CIRCUIT FOR THE BATHROOM. NEC 210.11 | | | (C)(3) | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-07-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-07-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-07-09 |
Time |
16:39 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-06-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-06-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-06-04 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2014-06-04 11:25:33 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-07-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-17 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-15 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2014-07-15 09:17:59 | TO JW DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-07-10 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-10 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-03 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2014-07-07 09:35:11 | RESUBMITTAL SENT TO JIM WITMER'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-06-10 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-06-10 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-05-28 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2014-05-29 13:05:02 | INCOMING SENT TO B09. JW |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-07-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-17 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-17 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-08 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-08 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2014-07-08 10:19:19 | PLUMBING PLAN REVIEW | | | PERMIT: 14050974 | | | ADD: 525 S FLAGLER DR # GPH3 | | | CONT: CAMBRIDGE CONSTRUCTION | | | TEL: (561)284-3722 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. JULY 08/2014 | | | ACTION: DENIED | | | | | | 1)) SHEETS D-100 & A-100 SHOW THE REMOVAL OF A TUB AND | | | NEW LOCATION FOR THE WATER CLOSET & BIDET. THERE IS NO | | | FLAT SANITARY NOR SANITARY ISOMETRIC DIAGRAM SHOWING | | | THE NEW SANITARY PIPING AND VENTING OF THESE FIXTURES. | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION107.3.5 MINIMUM PLAN | | | REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.3 PLUMBING | | | 1. MINIMUM PLUMBING FIXTURE CLEARANCES BIDET TO WATER | | | CLOSET FBC-P FIGURE 405.3.1. | | | 2. FIXTURE REQUIREMENTS | | | 3. SANITARY DRAINAGE & VENTS | | | | | | 3) A LETTER FROM THE CONDOMINIUM BOARD OR OWNER OF UNIT | | | BELOW GIVING APPROVAL FORACCESS TO WORK IN THEIRE UNIT. | | | HOW WILL THE FLOOR FIRE RATING BE MAINTAINED. | | | 2010 FBC-P 307.3 PENETRATIONS OF FLOOR/CEILING | | | ASSEMBLIES AND FIRE-RESISTANCE-RATED ASSEMBLIES. | | | PENETRATIONS OF FLOOR/CEILING ASSEMBLIES AND ASSEMBLIES | | | REQUIRED TO HAVE A FIRE-RESISTANCE RATING SHALL BE | | | PROTECTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, | | | BUILDING. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-06-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-05 |
Time |
19:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-05 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2014-06-05 19:18:16 | PLUMBING PLAN REVIEW | | | PERMIT: 14050974 | | | ADD: 525 S FLAGLER DR # GPH3 | | | CONT: CAMBRIDGE CONSTRUCTION | | | TEL: (561)284-3722 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURSDAY JUNE 05/2014 | | | ACTION: DENIED | | | | | | 1) PLANS SEALED BY OUT OF STATE ARCHITECT. FLORIDA | | | ADMINISTRATIVE RULE 61G1-16.002 DESCRIPTION OF SEAL. | | | (1) THE SEAL SHALL CONTAIN THE NAME OF ONLY ONE | | | ARCHITECT OR INTERIOR DESIGNER AND THE REGISTRATION | | | NUMBER; THE SEAL OF THE ARCHITECT SHALL BE CIRCULAR, | | | AND THE SEAL OF THE INTERIOR DESIGNER SHALL BE | | | HEXAGONAL. BOTH SEALS SHALL BE APPROXIMATELY 2" IN | | | DIAMETER WITH TWO CIRCULAR LINES BETWEEN WHICH LINES | | | SHALL APPEAR, AT THE TOP, THE WORDS ?STATE OF FLORIDA? | | | AND AT THE BOTTOM THE WORDS ?REGISTERED ARCHITECT? OR | | | ?LICENSED INTERIOR DESIGNER,? WHICHEVER IS APPLICABLE. | | | | | | 2) SHEETS D-100 & A-100 SHOW THE REMOVAL OF A TUB AND | | | NEW LOCATION FOR THE WATER CLOSET & BIDET. THERE IS NO | | | FLAT SANITARY NOR SANITARY RISER DIAGRAM SHOWING THE | | | NEW SANITARY PIPING AND VENTING OF THESE FIXTURES. 2010 | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION107.3.5 MINIMUM PLAN | | | REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.3 PLUMBING | | | 1. MINIMUM PLUMBING FIXTURE CLEARANCES BIDET TO WATER | | | CLOSET FBC-P FIGURE 405.3.1. | | | 2. FIXTURE REQUIREMENTS | | | 3. WATER SUPPLY PIPING | | | 4. SANITARY DRAINAGE | | | 5. VENTS | | | 6.PLUMBING RISE | | | | | | 3) THE SANITARY WASTE WILL BE ROUTED THROUGH THE FLOOR | | | BELOW HOW WILL THE CONTRACTOR GAIN ENTRY. HOW WILL THE | | | FLOOR FIRE RATING BE MAINTAINED. | | | 2010 FBC-P 307.3 PENETRATIONS OF FLOOR/CEILING | | | ASSEMBLIES AND FIRE-RESISTANCE-RATED ASSEMBLIES. | | | PENETRATIONS OF FLOOR/CEILING ASSEMBLIES AND ASSEMBLIES | | | REQUIRED TO HAVE A FIRE-RESISTANCE RATING SHALL BE | | | PROTECTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, | | | BUILDING. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |