Plan Review Details - Permit 14050931
| Plan Review Stops For Permit 14050931 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-28 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-28 |
Time |
07:21 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-07-17 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-17 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-17 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2014-07-17 12:02:22 | DATE: 7/14/2014 | | | PROJECT: MALVERNE RESIDENCE | | | PERMIT#: 14050937 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 3RD ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) AN INTER SYSTEM BOND IS REQUIRED AT THE SERVICE. NEC | | | 250.94. | | | | | | 2) A SWITCH CONTROLLED LIGHT IS REQUIRED AT THE ATTIC | | | ACCESS. FOR ATTICS, UNDERFLOOR SPACES, UTILITY ROOMS, | | | AND BASEMENTS, AT LEAST ONE LIGHTING OUTLET CONTAINING | | | A SWITCH OR CONTROLLED BY A WALL SWITCH SHALL BE | | | INSTALLED WHERE THESE SPACES ARE USED FOR STORAGE OR | | | CONTAIN EQUIPMENT REQUIRING SERVICING. AT LEAST ONE | | | POINT OF CONTROL SHALL BE AT THE USUAL POINT OF ENTRY | | | TO THESE SPACES. THE LIGHTING OUTLET SHALL BE PROVIDED | | | AT OR NEAR THE EQUIPMENT REQUIRING SERVICING. NEC | | | 210.70(3) | | | | | | 3) INDICATE A SMOKE AND C/O DETECTION SYSTEM AS | | | REQUIRED PER FBC-R 314, 315 | | | "EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING | | | BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS | | | ISSUED AND HAVING A FOSSIL-FUEL-BURNING HEATER OR | | | APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE, OR OTHER | | | FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE | | | AS A BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL | | | CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH | | | ROOM USED FOR SLEEPING PURPOSES". FBC-R 315.1 | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-06-12 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-06-12 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-12 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2014-06-12 15:36:50 | PROJECT: 210 MALVERNE RD. | | | | | | 2ND ELECTRICAL.REVIEW | | | | | | ACTION: FAILED | | | | | | CODE REFERENCED: 2008 EDITION OF THE NEC AND THE 2010 | | | EDITION OF THE FLORIDA BUILDING CODE. | | | | | | 1) A GROUNDING ELECTRODE SYSTEM IS REQUIRED AT THE | | | SERVICE. NEC 250.50. | | | | | | 2) AN INTER SYSTEM BOND IS REQUIRED AT THE SERVICE. NEC | | | 250.94. | | | | | | 3) INDICATE ALL REQUIRED OUTLETS PER NEC 210.52. | | | | | | 4) INDICATE A SMOKE DETECTION SYSTEM AS REQUIRED PER | | | FBC-R 314, 315 | | | | | | 5) INDICATE CIRCUITRY ON FLOOR PLAN. FBC 107.2.1 | | | | | | 6) INDICATE DISCONNECTS WHERE REQUIRED AT A/C EQUIPMENT | | | ETC.. NEC 440.14 | | | | | | 7) GFCI OUTLET REQUIRED AT A/C EQUIPMENT. NEC 210.63 | | | | | | NOTE: FBC 107.2.1 STATES IN PART: | | | "CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN" | | | | | | THEREFORE. PER THE FBC 107.2.1 AS STATED ABOVE, | | | ADDITIONAL CLARIFICATION IS REQUIRED TO CLARIFY THE | | | SCOPE OF WORK: | | | | | | 8) THE PERSON RESPONSIBLE FOR THE DESIGN IS REQUIRED TO | | | PUT THEIR NAME AND SIGNATURE ON THE PLAN. | | | | | | 9) INDICATE SPECIFICALLY WHAT IS EXISTING TO REMAIN AND | | | WHAT IS PROPOSED TO BE NEW. | | | | | | 10) INDICATE THE LOCATION OF THE SERVICE AND THE | | | ELECTRICAL PANELS. | | | | | | 11) INDICATE THE NAMES AND LOCATIONS OF ROOMS. EG. | | | "BEDROOM, KITCHEN LIVINGROOM" AND SEPARATION OF | | | APARTMENTS OR EFFICIENCIES. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR AT [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-06-02 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-06-02 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-02 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2014-06-02 07:42:35 | PROJECT: 210 MALVERNE RD. | | | | | | 1ST REVIEW ELECTRICAL. | | | | | | ACTION: FAILED | | | | | | CODE REFERENCED: 2008 EDITION OF THE NEC AND THE 2010 | | | EDITION OF THE FLORIDA BUILDING CODE. | | | | | | COMMENTS: | | | | | | 1) A GROUNDING ELECTRODE SYSTEM IS REQUIRED AT THE | | | SERVICE. NEC 250.50. | | | | | | 2) AN INTER SYSTEM BOND IS REQUIRED AT THE SERVICE. NEC | | | 250.94. | | | | | | 3) INDICATE ALL REQUIRED OUTLETS PER NEC 210.52. | | | | | | 4) INDICATE A SMOKE DETECTION SYSTEM AS REQUIRED PER | | | FBC-R 314, 315 | | | | | | 5) INDICATE CIRCUITRY ON FLOOR PLAN. FBC 107.2.1 | | | | | | 6) INDICATE DISCONNECTS WHERE REQUIRED AT A/C EQUIPMENT | | | ETC.. NEC 440.14 | | | | | | 7) GFCI OUTLET REQUIRED AT A/C EQUIPMENT. NEC 210.63 | | | | | | NOTE: FBC 107.2.1 STATES IN PART: | | | "CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN" | | | | | | THEREFORE. PER THE FBC 107.2.1 AS STATED ABOVE, | | | ADDITIONAL CLARIFICATION IS REQUIRED TO CLARIFY THE | | | SCOPE OF WORK: | | | | | | 8) THE PERSON RESPONSIBLE FOR THE DESIGN IS REQUIRED TO | | | PUT THEIR NAME AND SIGNATURE ON THE PLAN. | | | | | | 9) INDICATE SPECIFICALLY WHAT IS EXISTING TO REMAIN AND | | | WHAT IS PROPOSED TO BE NEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR AT [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-07-17 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-07-17 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-07-15 |
Time |
18:18 |
Sent To |
|
|
| Notes |
| 2014-07-16 18:18:32 | TO DAH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-06-12 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-06-12 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-09 |
Time |
18:21 |
Sent To |
|
|
| Notes |
| 2014-06-09 18:22:20 | TO RM DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-06-02 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-06-02 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-05-28 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2014-05-28 12:51:42 | SENT TO ELECTRICAL UNDER $5,000.00 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-06-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-12 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-12 |
Time |
15:09 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-28 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-28 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-05-28 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-28 |
Time |
07:21 |
Sent To |
|
|
| Notes |
| 2014-05-28 07:23:52 | REPLACE BATH TUB AND SHOWER IN SAME LOCATIONS. |
|
|
|