| Plan Review Stops For Permit 14050930 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2014-12-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-10 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-10 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2014-11-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-05 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-04 |
Time |
18:46 |
Sent To |
|
|
| Notes |
| 2014-11-05 14:40:31 | DENIED BY BUILDING | | | | | | 1) THE FL NUMBER FOR THE SINGLE HUNG WINDOWS THAT IS | | | SPECIFIED ON THE PLANS AS BEING IMPACT RATED IS NOT | | | ACCORDING TO THE PRODUCT APPROVAL. PLEASE CLARIFY. | | | PRODUCT APPROVALS FOR IMPACT PROTECTION DEVICES AND AN | | | INSTALLATION SCHEDULE WILL BE REQUIRED IF NON-IMPACT | | | WINDOWS ARE USED. FBC 107.2.1, FBCR 301.2.1.2 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] | | 2014-10-30 10:23:10 | UNABLE TO LOCATE THE PLANS. THEY HAVE NOT BEEN IN R15 | | | FOR AL LEAST TWO WEEKS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-08-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-22 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-22 |
Time |
07:21 |
Sent To |
|
|
| Notes |
| 2014-08-22 12:47:20 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE WIND DESIGN DATA ON SHEET A-01 HAS DIFFERENT | | | EXPOSURE CATEGORIES FOR EACH SIDE OF THE STRUCTURE. | | | ASCE 7 - 10 SECTION 26.7.4.2 REQUIRES WIND LOADS FOR | | | THE DESIGN OF THE MWFRS TO BE BASED ON THE EXPOSURE | | | CATEGORY RESULTING IN THE HIGHEST WIND LOADS FOR ANY | | | WIND DIRECTION AT THE THE SITE. ASCE 7 - 10 SECTION | | | 26.7.4.4 REQUIRES DESIGN WIND PRESSURES FOR COMPONENTS | | | AND CLADDING TO BE BASED ON THE EXPOSURE CATEGORY | | | RESULTING IN THE HIGHEST WIND LOADS FOR ANY WIND | | | DIRECTION AT THE THE SITE. THE HIGHEST EXPOSURE | | | CATEGORY THAT WAS SPECIFIED ON THE PLANS IS EXPOSURE C. | | | THEREFORE, THE DESIGN FOR THE MWFRS AND THE COMPONENT | | | AND CLADDING PRESSURES ARE TO BE BASED ON EXPOSURE C. | | | PLEASE REVISE THE PLANS. | | | | | | 2) BASED ON FBCR TABLES R301.2(2), R301.2(3) & | | | R301.2(4), THE COMPONENT AND CLADDING PRESSURES FOR THE | | | EXTERIOR DOORS AND WINDOWS ON THE PLANS APPEAR TO BE | | | HIGHER THAN REQUIRED. FBCR 301.2.1.1 ALLOWS THE WIND | | | SPEED TO BE CONVERTED TO NOMINAL WIND SPEEDS VASD WHEN | | | THEIR TEST STANDARDS ARE BASED ON THE NOMINAL WIND | | | SPEEDS. | | | | | | 3) THE MAXIMUM DESIGN PRESSURES ON THE PRODUCT APPROVAL | | | FOR THE OVERHEAD GARAGE DOOR ARE LOWER THAN THE | | | REQUIRED DESIGN PRESSURES SPECIFIED ON THE PLANS. | | | PLEASE CORRECT. FBCR 301.2.1 | | | | | | 4) FBCR 803.2.3.1 REQUIRES THE ROOF SHEATHING TO BE | | | FASTENED WITH 8D RING SHANK NAILS AT 6" O.C. & IF THE | | | ROOF FRAMING HAS A SPECIFIC GRAVITY OF 0.42 TO 0.49 THE | | | FASTENING SPACING SHALL BE 4 INCHES ON CENTER IN ROOF | | | ZONE 3. | | | | | | 5) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE | | | DWELLING. FBC ENERGY 401.2 | | | | | | 6) PROVIDE A BUCK DETAIL FOR THE 9' X 7' OVERHEAD | | | GARAGE DOOR ON THE PLAN. FBCR 612.10.2.1 SPECIFY HOW | | | THE 2 X 6S ARE ATTACHED TO THE STRUCTURE. | | | | | | 7) SUBMIT PRODUCT APPROVALS FOR ALL OF THE CONNECTORS | | | AS REQUIRED BY DCA RULE 9N-3 OR SPECIFY THE FLORIDA OR | | | MIAMI-DADE PRODUCT APPROVAL NUMBERS IN THE | | | ANCHOR/CONNECTOR SCHEDULE. THE PRODUCT APPROVAL NUMBERS | | | ARE NOT PROVIDED. THE MIAMI DADE NOA NO. OR THE STATE | | | FL # IS REQUIRED. | | | | | | 8) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE | | | STRUCTURAL WINDOW MULLIONS AS REQUIRED BY DCA RULE | | | 9N-3. | | | | | | 9) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | | THE PROJECT. | | | | | | 10) THE WINDOW TYPES ARE NOT IDENTIFIED ON THE PLANS. | | | FROM THE DRAWINGS IT APPEARS THAT ALL OF THE WINDOWS | | | ARE SINGLE HUNG. PRODUCT APPROVALS WERE SUBMITTED FOR A | | | FIXED WINDOW. PLEASE IDENTIFY THIS WINDOW ON THE PLANS. | | | CITY AMENDMENTS 107.2.1 | | | | | | 11) THE INFORMATION THAT WAS SUBMITTED FOR THE SINGLE | | | HUNG WINDOWS AND THE DOORS DOES NOT HAVE THE FLORIDA OR | | | MIAMI DADE PRODUCT APPROVAL ON THEM. PLEASE PROVIDE THE | | | SHEETS WITH THIS INFORMATION SO THAT THEY CAN BE | | | VERIFIED. DCA RULE 9N-3. | | | | | | 12) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-02 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-30 |
Time |
18:33 |
Sent To |
|
|
| Notes |
| 2014-07-01 09:52:46 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) SPECIFY THE WIND DESIGN DATA ON THE PLANS. CITY | | | AMENDMENTS 107.3.5.3 & FBCR 301.1 | | | | | | 2) SPECIFY THE COMPONENT AND CLADDING PRESSURES FOR THE | | | EXTERIOR DOORS AND WINDOWS ON THE PLANS. FBCR 301.2.1 | | | | | | 3) THE EXTERIOR BEARING WALLS OF THIS STRUCTURE DO NOT | | | HAVE A TWO HOUR FIRE RATING AS REQUIRED FOR TYPE III-B | | | CONSTRUCTION. IT IS TYPE V-B PER FBC 602. PLEASE | | | CORRECT. | | | | | | 4) SPECIFY THE REQUIRED TRUSS (LIVE AND DEAD) DESIGN | | | LOADS ON THE PLANS. FBCR 301.6 AND R801.2 | | | | | | 5) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE | | | DWELLING. FBC ENERGY 401.2 | | | | | | 6) SPECIFY THE ROOF SHEATHING THAT WILL BE INSTALLED ON | | | THE PLANS. | | | | | | 7) SHOW COMPLIANCE WITH FBCR 803.2.3.1 FOR FASTENING OF | | | ROOF SHEATHING. | | | | | | 8) SHOW COMPLIANCE WITH FBCR 806 FOR ROOF VENTILATION. | | | | | | 9) PROVIDE A BUCK DETAIL FOR THE 9' X 7' OVERHEAD | | | GARAGE DOOR ON THE PLAN. FBCR 612.10.2.1 | | | | | | 10) PROVIDE A BUCK DETAIL FOR THE SIDE SWING DOORS ON | | | THE PLAN. FBCR 612.10.2.1 | | | | | | 11) SPECIFY THE ANCHORS THAT WILL BE USED TO ATTACH THE | | | DOUBLE 2 X 10 BEAM TO THE STRUCTURE AT THE FRONT PORCH. | | | FBCR 301.1 | | | | | | 12) SPECIFY THE ANCHORS THAT WILL BE USED TO ATTACH THE | | | DOUBLE 2 X 12 BEAM TO THE STRUCTURE AT BEDROOM #1. FBCR | | | 802.1.9 ( A GIRDER TRUSS COULD BE USED) | | | | | | 13) SPECIFY ALL OF THE CONNECTORS THAT WILL BE USED ON | | | THE FRAMED GABLE WALL SHOWN IN DETAIL S-6 ON SHEET | | | S-02. FBCR 301.1 | | | | | | 14) THE SIMPSON MST 36 STRAP SHOWN IN DETAIL S-5 ON | | | SHEET S-02 DOES NOT HAVE ANY LATERAL LOAD RESISTANCE | | | AND THE TRUSS CLIP IS NOT IDENTIFIED. PROVIDE A TRUSS | | | ANCHOR/CONNECTOR SCHEDULE. FBCR 802.1.9 | | | | | | 15) SUBMIT PRODUCT APPROVALS FOR ALL OF THE CONNECTORS | | | AS REQUIRED BY DCA RULE 9N-3 OR SPECIFY THE FLORIDA OR | | | MIAMI-DADE PRODUCT APPROVAL NUMBERS IN THE | | | ANCHOR/CONNECTOR SCHEDULE. | | | | | | 16) SHOW THAT THE DOOR FROM THE GARAGE TO THE RESIDENCE | | | COMPLIES WITH FBCR 302.5.1. | | | | | | 17) NO INFORMATION IS PROVIDED ON THE PLANS FOR THE | | | INTERIOR DOORS. PLEASE PROVIDE A DOOR SCHEDULE. CITY | | | AMENDMENTS 107. | | | | | | 18) SHOW COMPLIANCE WITH FBCR 310.1 FOR EMERGENCY | | | ESCAPE AND RESCUE OPENINGS IN THE SLEEPING ROOMS. | | | | | | 19) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | EXTERIOR DOORS AND WINDOWS, THE ASPHALT ROOF SHINGLES | | | AND THE OVERHEAD GARAGE DOOR. DCA RULE 9N-3 | | | | | | 20) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | | THE PROJECT. | | | | | | 21) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2014-12-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-10 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-10 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2014-11-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-05 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-04 |
Time |
18:53 |
Sent To |
|
|
| Notes |
| 2014-11-05 15:15:10 | DENIED BY ELECTRICAL | | | | | | 1) THE ELECTICAL LOAD CALCULATIONS, THE PANEL SCHEDULE | | | AND THE RISER PLAN SPECIFY A 150 AMP PANEL. THE | | | ELECTRICAL FLOOR PLAN SPECIFIES A 100 AMP PANEL. PLEASE | | | CORRECT. FBC 107.2.1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-08-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-22 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-22 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2014-08-22 07:21:24 | 2010 FBC / 2008 NEC | | | | | | ELECTRICAL DENIED | | | | | | THE NEW 100 AMP PANEL THAT IS SPECIFIED ON THE | | | ELECTRICAL PLAN APPEARS TO BE TOO SMALL FOR THIS SINGLE | | | FAMILY DWELLING. PLEASE ADDRESS THE FOLLOWING COMMENTS. | | | | | | 1) SUBMIT TWO SETS OF LOAD CALCULATIONS AND PANEL | | | SCHEDULE ON THE PLANS. CITY AMENDMENTS 107.3.5.3 | | | | | | 2) PROVIDE AN ELECTRICAL SERVICE RISER DIAGRAM WITH | | | WIRE SIZES, CONDUIT DETAIL AND GROUNDING DETAIL ON THE | | | PLANS. CITY AMENDMENTS 107.3.5.3 | | | | | | 3) SPECIFY THE AIC RATING OF THE ELECTRICAL EQUIPMENT | | | ON THE PLANS. NEC 110.9 | | | | | | 4) THE 2008 NEC IS THE APPLICABLE ELECTICAL CODE FOR | | | THIS PROJECT. PLEASE CORRECT THE REFERENCE TO THE 2013 | | | NEC ON SHEET E-01. | | | | | | 5) THE NOTE IN THE UPPER RIGHT SIDE OF THE PLAN | | | SPECIFIES THE SFBC 2010. THERE IS NO LONGER AN SFBC. | | | THIS SHOULD BE FBC ( FLORIDA BUILDING CODE ) 2010. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-01 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-07-01 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2014-07-01 08:47:52 | 2010 FBC / 2008 NEC | | | | | | ELECTRICAL DENIED | | | | | | 1) SUBMIT TWO SETS OF LOAD CALCULATIONS AND PANEL | | | SCHEDULE ON THE PLANS. CITY AMENDMENTS 107.3.5.3 | | | | | | 2) PROVIDE AN ELECTRICAL SERVICE RISER WITH WIRE SIZES, | | | CONDUIT DETAIL AND GROUNDING DETAIL ON THE PLANS. CITY | | | AMENDMENTS 107.3.5.3 | | | | | | 3) SPECIFY THE AIC RATING OF THE ELECTRICAL EQUIPMENT | | | ON THE PLANS. NEC 110.9 | | | | | | 4) AN A/C SERVICE RECEPTACLE OUTLET IS REQUIRED IN AN | | | ACCESSIBLE LOCATION FOR THE EXTERIOR CONDENSING UNIT. | | | NEC 210.63 | | | | | | 5) SHOW COMPLIANCE WITH NEC 406.11 FOR TAMPER-RESISTANT | | | RECEPTACLES. | | | | | | 6) GFCI PROTECTION IS REQUIRED FOR RECEPTACLE OUTLETS | | | LOCATED IN THE GARAGE AND ON THE EXTERIOR OF THE | | | DWELLING. NEC 210.8 | | | | | | 7) SHOW COMPLIANCE WITH NEC 250.94 FOR INTERSYSTEM | | | BONDING. | | | | | | 8) SHOW COMPLIANCE WITH NEC 210.70(3) FOR THE REQUIRED | | | LIGHTING OUTLET IN THE ATTIC. | | | | | | IN ORDER TO REDUCE REVIEW TIME, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW THE REVIEW ITEMS HAVE | | | BEEN ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-10-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-10-30 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-10-30 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-07-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-07-02 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-07-02 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-06-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-06-02 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-06-02 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2014-06-02 11:51:32 | PER APRIL HPB APPROVAL REQUIRES CENTER WINDOW TO BE | | | PICTURE FLANKED BY CASEMENTS. FRIEDERIKE MITTNER SPOKE | | | TO BRADLEY AND CONFIRMED REVISION IS REQURIED 6/2/14. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2014-12-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-10 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-18 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2014-11-19 08:43:36 | INCOMING SENT TO R. MCDOUGALS DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-11-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-05 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-10-02 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-08-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-22 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-01 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2014-08-05 14:40:31 | RE-SUBMITTAL SENT TO ROBERT MCDOUGAL'S DESK FOR REVIEW. | | | JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-07-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-02 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-05-27 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2014-12-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-10 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-10 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2014-12-10 16:52:55 | BECAUSE CONDITIONED SPACE IS BEING ADDED, AND IMPACT | | | FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED. ONE SET OF | | | THE APPROVED PLANS CAN BE SIGNED OUT AND TAKEN TO PALM | | | BEACH COUNTY FOR THE REVIEW. THE STAMPED PLANS AND A | | | COPY OF THE PAID IMPACT FEE RECEIPT SHALL BE SUBMITTED | | | TO THE CITY'S BUILDING DEPARTMENT BEFORE THE PERMIT CAN | | | BE ISSUED. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2014-08-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-22 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-22 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2014-08-22 06:57:18 | BECAUSE CONDITIONED SPACE IS BEING ADDED, AND IMPACT | | | FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED. ONE SET OF | | | THE APPROVED PLANS CAN BE SIGNED OUT AND TAKEN TO PALM | | | BEACH COUNTY FOR THE REVIEW. THE STAMPED PLANS AND A | | | COPY OF THE PAID IMPACT FEE RECEIPT SHALL BE SUBMITTED | | | TO THE CITY'S BUILDING DEPARTMENT BEFORE THE PERMIT CAN | | | BE ISSUED. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-01 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-30 |
Time |
18:33 |
Sent To |
|
|
| Notes |
| 2014-08-22 06:57:46 | AN IMPACT FEE REVIEW WILL BE REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2014-12-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-12-10 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-12-10 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2014-12-10 16:17:12 | REVISED MECHANICAL PLANS ARE REQUIRED TO BE SUBMITTED | | | AND APPROVED BEFORE FINAL INSPECTION. THE PLANS THAT | | | WERE SUBMITTED HAVE REDLINED CORRECTIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2014-10-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-10-09 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
rbergsma |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-10-09 14:42:16 | MECHANICAL DENIED | | | | | | THE ENERGY CALC'S MAKE ASSUMTIONS THAT ARE NOT | | | SUPPORTED BY FACTS; | | | THE AREA OF DUCTWORK IN THE ATTIC = 272 SQ FT, WITHOUT | | | DUCT SIZING HOW WAS THIS DETERMINED | | | | | | THIS IS A LEVEL 3 ALTERATION AND ADDITION, PROVIDE | | | COMPLETE MECHANICAL DRAWINGS FOR REVIEW AND APPROVAL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2014-08-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-21 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-21 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2014-08-21 17:05:12 | NOTES ON THE PLANS STATE THAT THE MECHANICAL PLANS WILL | | | BE SUBMITTED UNDER A SEPARATE PERMIT. SEPARATE PERMIT, | | | APPLICATION AND REVIEW IS REQUIRED FOR THE MECHANICAL | | | WORK. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-07-01 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-30 |
Time |
18:33 |
Sent To |
|
|
| Notes |
| 2014-07-01 06:48:10 | 2010 FBC | | | | | | MECHANICAL DENIED | | | | | | 1) SUBMIT TWO COPIES OF MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBCR M1401.3 | | | | | | 2) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLANS THAT | | | MATCHES THE EQUIPMENT SIZING CALCULATIONS. FBCR M1401.3 | | | | | | 3) SPECIFY THE DUCT AND GRILL SIZES ON THE PLANS. FBCR | | | M1601 | | | | | | 4) SHOW COMPLIANCE WITH FBCR M1602.4 FOR BALANCED | | | RETURN AIR. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-01 |
Time |
05:05 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-11-01 |
Time |
05:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-06-30 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-06-30 |
Time |
18:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2014-08-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-08-22 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-08-22 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2014-08-22 10:10:55 | CERTAINTEED ASPHALT SHINGLE - NOA NO.11-0223.13 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-10-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-10-30 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-10-30 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-06-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-06-02 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-06-02 |
Time |
11:51 |
Sent To |
B |
|
| Notes |
|
|