Plan Review Details - Permit 14050851
Plan Review Stops For Permit 14050851
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-06-27 Cont ID  
Sent By jwitmer Date 2014-06-27 Time 07:52 Rev Time 0.00
Received By jwitmer Date 2014-06-27 Time 07:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-05-25 Cont ID  
Sent By jwitmer Date 2014-05-25 Time 10:15 Rev Time 0.00
Received By jwitmer Date 2014-05-25 Time 08:20 Sent To  
Notes
2014-05-25 09:47:25BUILDING PLAN REVIEW
 PERMIT: 14050851
 ADD: 777 S FLAGLER DR. SUITE # 900 W
 CONT: FISHER
 TEL: (561)691-4716
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SUNDAY MAY 25 TH/ 2014
 ACTION: DENIED
  
 NOTE, NO ACTION IS REQUIRED, ROOMS 904 & 912 FALL UNDER
 THE COMMON PATH OF TRAVEL BUSINESS OCC. SPRINKLERED
 BLDG 100 FEET WITH A OCCUPANT LOAD OF LESS THAN 49
 OCCUPANTS.
  
 1) THIS PERMIT IS A PHASED PERMIT, WITH A PHASE I AND
 PHASE II. THE PLANS DO NOT INDICATE IF THE PHASE II
 PART OF THE PROJECT WILL STATE AFTER PHASE 1 IS
 COMPLETE OR WILL THEY
 STAT AT THE SAME TIME AND ONLY PHASE 1 LOOK FOR A
 TEMPORARY C.O.? THE CONCERN IS THE 2ND PHASE
 COMPLETEING BEOFE THE 1ST PHASE, AND IF SO THE 2ND
 REQUIRED EXIT THAT WOULD BE IN THE PHASE 1 PORTION OF
 THE PERMIT. OCCUPANT LOADS > THAN 49 OCCUPANTS
 REQUIRING THE 2 EXITS, 2010 FBC-B 1015.1.
  
 2) THIS TENANT SPACE HAS 5 AREAS OF CONFERENCE ROOMS
 PLEASE SHOW COMPLIANCE WITH 2010 FBC-B 508.2.1 THAT
 THESE AREAS CAN BE CONSIDERED ACCESSORY OCCUPANCIES
 UNDER 2010 FBC-B 508.2.1. THE AREA FOR ALL BREAK ROOMS
 & CONFERENCE ROOMS HAS TO BE TAKEN INTO ACCOUNT.
 508.2.1 AREA LIMITATIONS. AGGREGATE ACCESSORY
 OCCUPANCIES SHALL NOT OCCUPY MORE THAN 10 PERCENT OF
 THE BUILDING AREA OF THE STORY IN WHICH THEY ARE
 LOCATED AND SHALL NOT EXCEED THE TABULAR VALUES IN
 TABLE 503, WITHOUT BUILDING AREA INCREASES IN
 ACCORDANCE WITH SECTION 506 FOR SUCH ACCESSORY
 OCCUPANCIES.
  
 BOAF INFORMAL INTERPRETATION REPORT # 6506
 DATE: THU JUN 3 2010
 REPORT: 6506
 CODE: BUILDING CODE YEAR: 2007
 SECTION: 508.3.1
 QUESTION:
 IS IT THE INTENT OF FLORIDA BUILDING CODE - BUILDING
 SECTION 508.3.1, EXCEPTION 1, TO NOT REQUIRE FIRE
 SEPARATION BETWEEN THE
 PRIMARY OCCUPANCY AND MULTIPLE ACCESSORY OCCUPANCIES,
 WHEN EACH ACCESSORY OCCUPANCY IS LESS THAN 750 SQ. FEET
 EACH OR
 ONLY WHEN THE TOTAL OF ALL ACCESSORY OCCUPANCIES IS
 LESS THAN 750 SQ. FEET IN AREA?
 COMMENT:
 AN EXAMPLE WOULD BE A BUSINESS OCCUPANCY WITH ONE
 ACCESSORY AREA OF 700SF FOR GATHERINGS AND MEETINGS AND
 A SECOND
 ACCESSORY AREA OF 650SF FOR FITNESS AND WORKOUT. IS THE
 EXCEPTION LIMITATION OF 750 S.F. MAX APPLIED TO EACH
 ACCESSORY AREA, IN
 WHICH CASE THIS BUILDING WOULD COMPLY, OR TO THE
 COMBINED TOTAL OF THE TWO ACCESSORY AREAS, IN WHICH
 CASE IT WOULD NOT?
 ANSWER:
 NO. CONSIDERING BOTH SPACES TO BE ASSEMBLY USES LOCATED
 ON THE SAME FLOOR, THE EXCEPTION TO FLORIDA BUILDING
 CODE - BUILDING
 SECTION 508.3.1 WOULD NOT REQUIRE SEPARATION OF EITHER
 SPACE. HOWEVER, THE SECTION TO WHICH THE EXCEPTION
 RELATES WOULD LIMIT
 THE AGGREGATE ACCESSORY OCCUPANCIES TO 10% OF THE AREA
 OF THE FLOOR ON WHICH THEY ARE LOCATED. IF THE AREA OF
 TWO COMBINED
 ASSEMBLY USES EXCEEDED 10%, THEN AT LEAST ONE OF THE
 ASSEMBLY USES WOULD REQUIRE FIRE RESISTANT RATED
 SEPARATION OF 2 HOURS IN
 A NON-SPRINKLED BUILDING AND 1 HOUR IN A BUILDING
 SPRINKLED THROUGHOUT.
 COMMENTARY:
 NONE.
 NOTICE: THE BUILDING OFFICIALS ASSOCIATION OF FLORIDA,
 IN COOPERATION WITH THE FLORIDA BUILDING COMMISSION,
 THE FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ICC,
 AND INDUSTRY AND PROFESSIONAL EXPERTS OFFER THIS
 INTERPRETATION OF THE FLORIDA BUILDING CODE IN THE
 INTEREST OF CONSISTENCY IN THEIR APPLICATION STATEWIDE.
 THIS INTERPRETATION IS INFORMAL, NON-BINDING AND
 SUBJECT TO ACCEPTANCE AND APPROVAL BY THE LOCAL
 BUILDING OFFICIAL.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-07-03 Cont ID  
Sent By dhayes Date 2014-07-03 Time 14:14 Rev Time 0.00
Received By dhayes Date 2014-07-03 Time 14:14 Sent To  
Notes
2014-06-20 08:06:49NEW SHEETS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-06-10 Cont ID  
Sent By dhayes Date 2014-06-10 Time 15:58 Rev Time 0.00
Received By dhayes Date 2014-06-10 Time 15:58 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-07-10 Cont ID  
Sent By pleduc Date 2014-07-10 Time   Rev Time 0.00
Received By pleduc Date 2014-07-10 Time 12:07 Sent To PC
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2014-06-03 Cont ID  
Sent By pleduc Date 2014-06-03 Time   Rev Time 0.00
Received By pleduc Date 2014-06-03 Time 11:55 Sent To  
Notes
2014-06-03 12:05:45THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENT:
  
 PLEASE REVIEW AND ADDRESSED BUILDING COMMENTS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-07-10 Cont ID  
Sent By pleduc Date 2014-07-10 Time   Rev Time 0.00
Received By pleduc Date 2014-06-19 Time 08:07 Sent To PC
Notes
2014-06-20 08:07:32RESUBMITTAL SENT TO B9 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-06-10 Cont ID  
Sent By dhayes Date 2014-06-10 Time 15:58 Rev Time 0.00
Received By dhayes Date 2014-05-22 Time 17:23 Sent To  
Notes
2014-05-22 17:23:20ROUTE TO B3

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-06-27 Cont ID  
Sent By jwitmer Date 2014-06-27 Time 07:52 Rev Time 0.00
Received By jwitmer Date 2014-06-27 Time 07:46 Sent To  
Notes
2014-06-20 08:07:54NEW SHEETS SUBMITTED. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-05-29 Cont ID  
Sent By hmoser Date 2014-05-29 Time 16:09 Rev Time 0.00
Received By hmoser Date 2014-05-29 Time 16:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-06-27 Cont ID  
Sent By jwitmer Date 2014-06-27 Time 07:52 Rev Time 0.00
Received By jwitmer Date 2014-06-27 Time 07:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-05-25 Cont ID  
Sent By jwitmer Date 2014-05-25 Time 10:15 Rev Time 0.00
Received By jwitmer Date 2014-05-25 Time 08:20 Sent To  
Notes
2014-05-25 10:15:21PLUMBING PLAN REVIEW
 PERMIT: 14050851
 ADD: 777 S FLAGLER DR. SUITE # 900 W
 CONT: FISHER
 TEL: (561)691-4716
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SUNDAY MAY 25 TH/ 2014
 ACTION: DENIED
  
 1A) SHEET P1.1 NOTE # 3 SHOWS THE USE OF AN AIR
 ADMITTANCE VALVE, PLEASE PROVIDE HOW MANY FLOORS ARE
 LOCATED ABOVE THIS SUITE AND SHOW COMPLIANCE WITH 2010
 FBC-PLUMBING 917.3.1 LOCATION OF BRANCH. THE HORIZONTAL
 BRANCH DRAIN SHALL CONNECT TO THE DRAINAGE STACK OR
 BUILDING DRAIN A MAXIMUM OF FOUR BRANCH INTERVALS FROM
 THE TOP OF THE STACK.
  
 1B) PLEASE ALSO CONSIDER RETURN AIR PLENUMS AS FOUND ON
 SHEETS M2.1, PLEASE REVIEW 2010 FBC-PLUMBING SECTION
 17.8 PROHIBITED INSTALLATIONS. AIR ADMITTANCE VALVES
 SHALL NOT BE LOCATED IN SPACES UTILIZED AS SUPPLY OR
 RETURN AIR PLENUMS.
  
 2) SHEET P1.1 NOTE # 11 INDICATES THE USE OF A NEW
 DRINKING FOUNTAIN BUT THE SHEET DOES NOT SHOW A WASTE
 TO THE SANITARY SEWER. THE 2010 FBC-PLUMBING TABLE
 709.1 DRINKING FOUNTAINS 1/2 DFU'S AND MINIMUM TRAP
 SIZE OF 1 1/4 INCH.
  
 3) 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING. DRINKING
 FONTAINS UNDER THE FL ACCESSIBILITY CODE ARE REQUIRED
 TO COMPLY WITH 211.2 MINIMUM NUMBER.
 NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
 EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES
 WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE
 PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING
 FOUNTAINS.
 NO MONIES HAVE BEEN SPENT UNDER THE DIPROPORTIONATE
 COST 202.4.1.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2014-05-28 Cont ID  
Sent By ajones Date 2014-05-28 Time 11:27 Rev Time 0.00
Received By ajones Date 2014-05-28 Time 11:27 Sent To  
Notes
***NONE***