Plan Review Details - Permit 14050677
Plan Review Stops For Permit 14050677
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2014-06-25 Cont ID  
Sent By jwitmer Date 2014-05-26 Time 18:26 Rev Time 0.00
Received By jsaez Date 2014-05-26 Time 17:59 Sent To  
Notes
2014-05-26 18:26:47BUILDING PLAN REVIEW
 PERMIT: 14050677
 ADD: 303 BANYAN 1ST FLOOR COMMON RESTROOMS
 CONT: TBD
 TEL: (904)256-2151
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2010 FL ACCESSIBILITY CODE 604.8 WHEELCHAIR ACCESSIBLE
 TOILET COMPARTMENTS SHALL MEET THE REQUIREMENTS OF
 604.8.1 AND 604.8.3. COMPARTMENTS CONTAINING MORE THAN
 ONE PLUMBING FIXTURE SHALL COMPLY WITH 603
  
 . 603.2.3 DOOR SWING.
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
  
 EXCEPTIONS:
  
 2. WHERE THE TOILET ROOM OR BATHING ROOM IS FOR
 INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING WITH
 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE
 DOOR SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE
 CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY
 FIXTURE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-07-02 Cont ID  
Sent By dhayes Date 2014-07-02 Time 12:06 Rev Time 0.00
Received By dhayes Date 2014-07-02 Time 11:54 Sent To  
Notes
2014-07-02 13:28:49ROUTE TO J.S DESK.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-05-29 Cont ID  
Sent By pleduc Date 2014-05-29 Time   Rev Time 0.00
Received By pleduc Date 2014-05-29 Time 08:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-07-03 Cont ID  
Sent By skennedy Date 2014-07-03 Time 09:42 Rev Time 0.00
Received By skennedy Date 2014-05-20 Time 16:39 Sent To  
Notes
2014-05-20 16:41:30B06

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2014-07-03 Cont ID  
Sent By jsaez Date 2014-07-02 Time 14:48 Rev Time 0.00
Received By skennedy Date 2014-07-03 Time 09:42 Sent To  
Notes
2014-07-02 14:47:22N1. NO MECHANICAL PLANS.

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-05-26 Cont ID  
Sent By jwitmer Date 2014-05-26 Time 18:16 Rev Time 0.00
Received By jwitmer Date 2014-05-26 Time 17:59 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2014-06-12 Cont ID  
Sent By aaponte Date 2014-06-12 Time 14:30 Rev Time 0.00
Received By aaponte Date 2014-06-12 Time 14:30 Sent To  
Notes
***NONE***