Plan Review Details - Permit 14050634
Plan Review Stops For Permit 14050634
Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-07-31 Cont ID  
Sent By jgomez Date 2014-07-31 Time 09:38 Rev Time 0.00
Received By jgomez Date 2014-07-30 Time 17:22 Sent To  
Notes
2014-07-30 17:22:49SENT TO J GOMEZ FOR REVIEW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-07-09 Cont ID  
Sent By jgomez Date 2014-07-09 Time 08:49 Rev Time 0.00
Received By jgomez Date 2014-07-09 Time 08:49 Sent To  
Notes
2014-06-18 13:42:21TO JG DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-05-28 Cont ID  
Sent By jgomez Date 2014-05-28 Time 13:33 Rev Time 0.00
Received By jgomez Date 2014-05-15 Time 15:25 Sent To  
Notes
2014-05-22 10:51:02TO JGOMEZ TO REVIEW WITH 14041079
2014-05-15 15:25:40ROUTED TO MECHANICAL

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2014-07-31 Cont ID  
Sent By jgomez Date 2014-07-31 Time 09:38 Rev Time 0.00
Received By jgomez Date 2014-07-31 Time 09:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2014-07-09 Cont ID  
Sent By jgomez Date 2014-07-09 Time 08:50 Rev Time 0.00
Received By jgomez Date 2014-07-09 Time 08:49 Sent To  
Notes
2014-07-09 08:50:19RESIDENTIAL (R3) ADDITION/ALTERATION MECHANICAL REVIEW
 SECOND CHECKLIST.
 CODE: 2010 FBC.
  
 1- EQUIPMENT SIZING CALCULATIONS SUBMITTED:
 EQUIPMENT SIZING CALCULATIONS TO INCLUDE THE
 MANUFACTURER AND MODEL NUMBER OF THE OUTDOOR AND INDOOR
 UNITS ALONG WITH THE SENSIBLE AND TOTAL COOLING
 CAPACITIES AS REQUIRED BY SEC. 403.6 OF 2010 FBC-ENERGY
 CONSERVATION (REPEAT COMMENT).
  
 2- A/C PLAN:
 A) SIZE OF RETURN AIR TRANSFER DUCT IN THE MASTER
 BEDROOM DOESN'T COMPLY WITH EXCEPTION #1 OF SEC.
 M1602.4 OF 2010 FBC-RESIDENTIAL. THE SIZE OF THE
 TRANSFER DUCT NEED TO BE INCREASED TO 14" MIN. NOTE:
 ALL THE SUPPLY AIR INTO THE MASTER BEDROOM SHALL BE
 INCLUDED WHEN SIZING THE DUCT.
  
 B) PROVIDE NAME, SIGNATURE AND LICENSE NUMBER OF THE
 A/C CONTRACTOR DOING THE WORK AS REQUIRED BY FLORIDA
 STATUTE 471.003 AND SEC. 107.2.1 CITY AMENDMENTS TO
 FBC.
  
 C) PROVIDE AL THE EQUIPMENT INFORMATION (MANUFACTURER,
 MODEL ETC). . AND LOCATION INCLUDING THE CONDENSER
 UNIT. SEC. 107.3.5.3 CITY AMENDMENTS
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICE
 (561)805-6712

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-05-28 Cont ID  
Sent By jgomez Date 2014-05-28 Time 13:47 Rev Time 0.00
Received By jgomez Date 2014-05-28 Time 13:33 Sent To  
Notes
2014-05-28 13:49:19RESIDENTIAL (R3) ADDITION/ALTERATION MECHANICAL REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- EQUIPMENT SIZING CALCULATIONS SUBMITTED:
 CALCULATIONS ARE INCOMPLETE. CALCULATIONS NEED TO SHOW
 THE EQUIPMENT MANUFACTURER AND MODEL NUMBER AS REQUIRED
 BY SEC. 403.6 OF 2010 FBC-ENERGY CONSERVATION.
  
 2- PLANS AND EQUIPMENT SIZING CALCULATIONS SUBMITTED
 SHOW 2 EXISTING 2.5 TON UNITS. ACCORDING TO CITY
 RECORDS THERE ARE NO PERMITS FOR THE A/C EQUIPMENT
 REPLACEMENT IN THE LAST 14 YEARS. PROVIDE PROOF THAT
 EQUIPMENT IS THE ORIGINAL EQUIPMENT OF THE HOUSE OR
 PROVIDE COMPLETE INFORMATION AS REQUIRED BY SEC.
 101.4.7.1.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 3- A/C PLAN:
 A) PROVIDE NAME AND SIGNATURE OF PERSON RESPONSIBLE FOR
 THE DESIGN. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 B) PROVIDE AL THE EQUIPMENT INFORMATION (MANUFACTURER,
 MODEL ETC). . AND LOCATION INCLUDING THE CONDENSER
 UNIT. SEC. 107.3.5.3(1) CITY AMENDMENTS
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICE
 (561)805-6712