Plan Review Details - Permit 14050575
| Plan Review Stops For Permit 14050575 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-09-15 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-09-15 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2014-09-15 15:06:54 | BUILDING PLAN REVIEW | | | PERMIT: 14050575 | | | ADD: 951 HANK AARON DR | | | CONT: CORPORATE PROPERTY SERVICES, INC | | | TEL: (954) 426-5144 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: MOJN. SEPT. 15/ 2014 | | | ACTION: BUILDING PROVISO | | | | | | 1) ROOFING PRODUCT APPROVAL SUBMITTED FL 16039-R3 | | | DURO-LAST ROOFING INC. PAGE 39OF 40 OPTION W-M-6 GOOD | | | FOR -60 PSF AND LIMITATION #7 FOR ZONES 2 & 3 WILL | | | REQUIRE ENHANCED FASTENING, RAS 117 CALCULATIONS. IF | | | THE CALCULATIONS ARE NOT COMPLETED BY THE DESIGNER OF | | | RECORD, THEN THEY WILL NEED TO BE REVIEWED BY THE | | | DESIGNER OF RECORD BEFORE SUBMITTAL TO THE BUILDING | | | DEPARTMENT. | | | | | | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | | CHAPTER 6 OF ASCE- 7-10. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-09-15 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-09-15 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2014-09-15 15:07:27 | BUILDING PLAN REVIEW | | | PERMIT: 14050575 | | | ADD: 951 HANK AARON DR | | | CONT: CORPORATE PROPERTY SERVICES, INC | | | TEL: (954) 426-5144 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: MOJN. SEPT. 15/ 2014 | | | ACTION: BUILDING PROVISO | | | | | | 1) ROOFING PRODUCT APPROVAL SUBMITTED FL 16039-R3 | | | DURO-LAST ROOFING INC. PAGE 39OF 40 OPTION W-M-6 GOOD | | | FOR -60 PSF AND LIMITATION #7 FOR ZONES 2 & 3 WILL | | | REQUIRE ENHANCED FASTENING, RAS 117 CALCULATIONS. IF | | | THE CALCULATIONS ARE NOT COMPLETED BY THE DESIGNER OF | | | RECORD, THEN THEY WILL NEED TO BE REVIEWED BY THE | | | DESIGNER OF RECORD BEFORE SUBMITTAL TO THE BUILDING | | | DEPARTMENT. | | | | | | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | | CHAPTER 6 OF ASCE- 7-10. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | 2014-09-12 09:19:50 | 9/12 RETURNED TO BOARD, C14 | | | | | | RESTAMP NEEDED BY JW | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-07-27 |
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
2014-07-27 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-27 |
Time |
05:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-13 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
jsaez |
Date |
2014-06-12 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2014-06-13 11:27:25 | BUILDING PLAN REVIEW | | | PERMIT: 14050575 | | | ADD: 951 HANK AARON DR | | | CONT: CORPORATE PROPERTY SERVICES, INC | | | TEL: (954) 426-5144 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. JUNE 13/ 2014 | | | ACTION: DENIED | | | | | | 1) SHEET A5 ENLARGED RESTROOM PLANS INDICATE IN BOTH | | | THE MENS & WOMENS TOLIET COMPARTMENTS WITHIN THE | | | RESTROOM SWING INTO THE REQUIRED FIXTURE AREA. PLEASE | | | SEE THE 2010 FBC-ACCESSIBILITY CODE 604.8.1.2. THESE | | | ARE TOLIET COMPARTMENTS NOT SINGLE USER TOLIET ROOMS | | | WHICH ARE COVERED UNDER | | | 603.2.3 EXCEPTION # 2, TOILET ROOMS FOR INDIVIDUAL USE. | | | | | | 2) THE SUBMITTED PRODUCT APPROVALS HAVE NOT BEEN | | | REVIEWED BY THE DESIGNER OF RECORD. 2010 FBC 107.3.4.1 | | | PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED | | | BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 3) SUBMITTED NOA 12-1003.06 STYLE RIB METAL WALL PANEL | | | WAS NOT SUBMITTED WITH THE TECHNICAL SHEETS/ | | | INSTALATION SHEET. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 4) THE ROOFING APPROVAL FL 16039-R3 WAS SUBMITTED, NO | | | SUB-SYSTEM NOR PRESSURES WERE IDENTIFIED. 2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY | | | THE CODE, THE CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, | | | DESCRIBE AND DELINEATE THE TYPE OF ROOFING SYSTEM, | | | MATERIALS, FASTENING REQUIREMENTS, FLASHING | | | REQUIREMENTS AND WIND RESISTANCE RATING THAT ARE | | | REQUIRED TO BE | | | INSTALLED. PRODUCT EVALUATION AND INSTALLATION SHALL | | | INDICATE COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR | | | THE SPECIFIC SITE OR A STATEMENT BY AN ARCHITECT OR | | | ENGINEER FOR THE SPECIFIC SITE MUST BE SUBMITTED WITH | | | THE CONSTRUCTION DOCUMENTS | | | | | | 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-09-02 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-09-02 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-09-02 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-08-01 |
|
|
Cont ID |
|
| Sent By |
D HAYES |
Date |
2014-08-01 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-01 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2014-08-01 12:15:19 | DATE: 8/1/2014 | | | PROJECT: WEDNDY'S RENNOVATION | | | PERMIT#: 14050575 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) INDICATE THE LOCATION OF THE ELECTRICAL SERVICE AND | | | HOW THE UNFUSED SERVICE ENTRANCE CONDUCTORS ARE ROUTED | | | TO PANEL MDP. | | | | | | 2) REVISE ONE LINE RISER DIAGRAM TO INDICATE ALL FEEDER | | | SIZES, AND PANEL SCHEDULES FOR SERVICE ENTRANCE THROUGH | | | PANELS "MDP", "A" AND "B" | | | | | | 3) PROVIDE GROUNDING ELECTRODE SYSTEM DETAIL TO | | | INDICATE WIRE SIZES, MAIN BONDING JUMPER, AND ALL | | | AVAILABLE GROUNDING ELECTTRODE TYPES, SIZES AND | | | LOCATIONS. | | | | | | SEPARATE PERMITS ACCOMPANIED BY SHOP DRAWINGS REQUIRED | | | FOR SIGNS, SECURITY, NETWORK, CCTV, AUDIO/VIDEO AND FOR | | | THE INSTALLATION AND TERMINATION OF THE OUTDOOR MENU | | | BOARDS, CANOPY, AND PRE-SALE BOARD. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: HTTP://WPB.ORG/DEVELOPMENT | | | /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM | | | ITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-06-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-06-04 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-06-04 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2014-06-04 10:13:55 | ADDRESS: 951 HANK AARON DR. WPB | | | PERMIT#:14050575 | | | 1ST ELECTRICAL REVIEW | | | ACTION: DENIED. | | | CODE: 2008 NEC AND 2010 FBC | | | | | | DEFICIENCIES: | | | 1) THE ELECTRICAL SERVICE LOAD SUMMARY SUBMITTED IS | | | BASED ON AN EXISTING ELECTRICAL LOAD PER NEC 220.87. | | | | | | THIS NEC CODE ARTICLE QUOTED ON THE SUBMITTAL NEC | | | 220.87 STATES IN PART: | | | THE CALCULATION OF A FEEDER OR SERVICE LOAD FOR | | | EXISTING INSTALLATIONS SHALL BE PERMITTED TO USE | | | "ACTUAL MAXIMUM DEMAND" TO DETERMINE THE EXISTING LOAD | | | UNDER ALL OF THE FOLLOWING CONDITIONS: | | | 1) THE MAXIMUM DEMAND DATA IS AVAILABLE FOR A ONE YEAR | | | PERIOD. | | | 2) THE MAXIMUM DEMAND AT 125% PLUS THE NEW LOAD DOES | | | NOT EXCEED THE AMPACITY OF THE FEEDER OR RATING OF THE | | | SERVICE. | | | 3) THE FEEDER HAS OVERCURRENT PROTECTION IN ACCORDANCE | | | WITH 240.4 AND THE SERVICE HAS OVERLOAD PROTECTION IN | | | ACCORDANCE WITH 230.90. | | | | | | THE PROBLEM IS WHAT HAS BEEN SUBMITTED IS AN "ASSUMED | | | MAXIMUM DEMAND" WITH NO EVIDENCE OF THE "ACTUAL MAXIMUM | | | DEMAND" BEING SUBMITTED AT ALL. | | | | | | PLEASE COMPLY COMPLETELY WITH THE ARTICLE AS STATED OR | | | SUBMIT A COMPLETE ELECTRICAL LOAD SUMMARY SHOWING | | | COMPLIANCE WITH PART III OF ARTICLE 220, MORE | | | SPECIFICALLY ARTICLE 220.40 WHICH STATES: | | | | | | THE CALCULATED LOAD OF A FEEDER OR SERVICE SHALL NOT BE | | | LESS THAN THE SUM OF THE LOADS ON THE BRANCH CIRCUITS | | | SUPPLIED AS DETERMINED BY PART II OF ARTICLE 220, AFTER | | | ANY APPLICABLE DEMAND FACTORS PERMITTED BY PART III OR | | | IV OR REQUIRED BY PART V HAVE BEEN APPLIED. | | | | | | 2) PROVIDE SAFETY LABELING FOR FLASH PROTECTION AND FOR | | | THE PANEL BOARDS AND MAIN DISCONNECTING MEANS. NEC | | | 110.22, 110.16, 110.22 | | | | | | 3) THE BRANCH CIRCUIT FEEDING BATTERY BACKED EMERGENCY | | | AND EXIT LIGHTS SHALL BE THE SAME BRANCH CIRCUIT AS | | | THAT SERVING THE NORMAL LIGHTING IN THE AREA AND | | | CONNECTED AHEAD OF ANY LOCAL SWITCHES. NEC 701.11(G) | | | | | | 4) LIGHTING FOR ALL EXTERIOR APPLICATIONS NOT EXEMPTED | | | IN SECTION 505.1 SHALL HAVE AUTOMATIC CONTROLS CAPABLE | | | OF TURNING OFF EXTERIOR LIGHTING WHEN SUFFICIENT | | | DAYLIGHT IS AVAILABLE OR WHEN THE LIGHTING IS NOT | | | REQUIRED DURING NIGHTTIME HOURS. LIGHTING NOT | | | DESIGNATED FOR DUSK-TO-DAWN OPERATION SHALL BE | | | CONTROLLED BY AN ASTRONOMICAL TIME SWITCH OR | | | PHOTOSENSOR. ALL TIME SWITCHES SHALL BE CAPABLE OF | | | RETAINING PROGRAMMING AND THE TIME SETTING DURING LOSS | | | OF POWER FOR A PERIOD OF AT LEAST 10 HOURS. | | | | | | 5) ALL COMPONENTS AND CABLES SHALL BE UL LISTED AND | | | LABELED FOR USE IN THE MANNER INSTALLED. NEC 110.3 | | | | | | SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR SIGNS, | | | SECURITY, NETWORK, CCTV, AUDIO/VIDEO AND FOR THE | | | INSTALLATION AND TERMINATION OF THE OUTDOOR MENU | | | BOARDS, CANOPY, AND PRE-SALE BOARD. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421. | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2014-09-02 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2014-09-02 |
Time |
14:30 |
Rev Time |
0.50 |
| Received By |
cranford |
Date |
2014-09-02 |
Time |
14:30 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2014-07-31 |
|
|
Cont ID |
|
| Sent By |
MGONZALE |
Date |
2014-07-31 |
Time |
15:13 |
Rev Time |
3.00 |
| Received By |
cranford |
Date |
2014-07-31 |
Time |
14:20 |
Sent To |
E |
|
| Notes |
| 2014-07-31 15:12:47 | ENGINEERING DEPT COMMENTS | | | | | | 1. A RIGHT-OF-WAY PERMIT FROM THE ENGINEERING | | | DEPARTMENT WILL BE REQUIRED FOR ALL WORK WITHIN THE | | | CITY OF WEST PALM BEACH RIGHT-OF-WAY. THE APPLICATION | | | FORM AND CONSTRUCTION STANDARDS CAN BE FOUND AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 2. PLEASE REVISE THE PROPOSED PARKING LOT STRIPING TO | | | COMPLY WITH CITY OF WEST PALM BEACH CODE OF ORDINANCES, | | | ARTICLE XV, SECTION 94-485. | | | | | | 3. PLEASE REVISE THE HANDICAPPED PARKING DETAIL TO | | | MATCH THE DIMENSIONS SHOWN ON SHEET C2.0 AND TO MEET | | | FLORIDA BUILDING CODE REQUIREMENTS (SECT 11.4.6.4) | | | | | | KELLY E CRANFORD, PE | | | LAND DEVELOPMENT ENGINEER | | | ENGINEERING & PUBLIC SERVICES | | | CITY OF WEST PALM BEACH | | | [email protected] | | | (561)494-1098 | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2014-07-11 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2014-07-11 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2014-07-11 |
Time |
|
Sent To |
I |
|
| Notes |
| 2014-07-11 11:06:31 | ADDRESS PLANNING'S COMMENTS. | | | | | | SHOW EXISTING WATER AND SEWER SERVICE LOCATIONS. | | | | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-05-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-05-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-05-20 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-09-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2014-09-11 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2014-08-22 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2014-08-25 09:18:57 | RE-SUBMITTAL SENT TO C14 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-15 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2014-09-15 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-23 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-07-14 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-07-14 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-14 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2014-05-15 10:55:10 | SENT TO C14 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-07-27 |
|
|
Cont ID |
|
| Sent By |
JSAEZ |
Date |
2014-07-27 |
Time |
06:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-27 |
Time |
06:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-07-14 |
|
|
Cont ID |
|
| Sent By |
jsaez |
Date |
2014-07-14 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
jsaez |
Date |
2014-06-24 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2014-06-24 15:03:13 | 1.PROVIDE DETAIL ON ICE MAKER CONDENSERS | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-07-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-27 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-27 |
Time |
06:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-06-13 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-13 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2014-09-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2014-09-11 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2014-09-11 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2014-09-11 10:56:08 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 09.11.2014 | | | PERMIT NO.: 14050575 | | | ADDRESS: 951 HANK AARON DRIVE | | | CONTRACTOR/CONTACT: BRANDI | | | TELEPHONE NO.: 954.426.5144 | | | SCOPE OF REVIEW: RENOVATIONS TO EXISTING DRIVE-THRU | | | RESTAURANT. | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY | | | (CO): | | | | | | A. A SEPARATE LANDSCAPE PERMIT APPLICATION SHALL BE | | | SUBMITTED FOR THE INSTALLATION OF THE NEW LANDSCAPING. | | | THE APPLICATION SHALL BE ACCOMPANIED BY TWO (2) SETS OF | | | SIGNED/SEALED LANDSCAPE PLANS, AS WELL AS A CERTIFIED | | | COST ESTIMATE INDICATING THE OVERALL COST (LABOR + | | | MATERIALS). | | | | | | B. THE SPACING OF THE SIGN ON THE DINING SIDE | | | ELEVATION SHALL BE SUCH THAT THE OVERALL HEIGHT FROM | | | THE TOP OF ?WENDY?S? TO THE BOTTOM OF ?QUALITY IS OUR | | | RECIPE? SHALL NOT EXCEED 48 INCHES | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | | | 2014-08-26 13:26:01 | 8/26/14 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-08-07 |
|
|
Cont ID |
|
| Sent By |
JROACH |
Date |
2014-08-07 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2014-08-05 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2014-08-07 11:55:40 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 08.07.2014 | | | PERMIT NO.: 14050575 | | | ADDRESS: 951 HANK AARON DRIVE | | | CONTRACTOR/CONTACT: BRANDI | | | TELEPHONE NO.: 954.426.5144 | | | SCOPE OF REVIEW: INTERIOR AND EXTERIOR REMODEL OF | | | EXISTING RESTAURANT. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE PARKING DETAIL ON SHEET C4.0 IS INCORRECT. | | | PLEASE USE THE LATEST ?DETAIL? SHEET, DATED JUNE 27, | | | 2014, AND APPROVED THROUGH THE MINOR PD AMENDMENT | | | PROCESS. PLEASE ENSURE THAT ALL PLANS MATCH THAT WHICH | | | WAS APPROVED AS PART OF THE MINOR PD AMENDMENT. | | | | | | 2. A SEPARATE LANDSCAPE PERMIT APPLICATION SHALL BE | | | SUBMITTED FOR THE INSTALLATION OF THE NEW LANDSCAPING. | | | THE APPLICATION SHALL BE ACCOMPANIED BY TWO (2) SETS OF | | | SIGNED/SEALED LANDSCAPE PLANS, AS WELL AS A CERTIFIED | | | COST ESTIMATE INDICATING THE OVERALL COST (LABOR + | | | MATERIALS). | | | | | | 3. A SEPARATE SIGN PERMIT APPLICATION SHALL BE | | | SUBMITTED FOR THE INSTALLATION OF THE WALL-MOUNTED | | | SIGNS. PLEASE NOTE THAT THE SIGNAGE SHOWN ON THE | | | PROPOSED ELEVATIONS DOES NOT MATCH THAT WHICH WAS | | | APPROVED THROUGH THE MINOR PD AMENDMENT PROCESS. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-06-23 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2014-06-23 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2014-06-23 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2014-06-23 15:10:22 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 06.23.2014 | | | PERMIT NO.: 14050575 | | | ADDRESS: 951 HANK AARON DRIVE | | | CONTRACTOR/CONTACT: BRANDI | | | TELEPHONE NO.: 954.426.5144 | | | SCOPE OF REVIEW: INTERIOR AND EXTERIOR REMODEL OF | | | EXISTING RESTAURANT | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PURSUANT TO SECTION 94-441 OF THE CITY'S ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS), BECAUSE THE | | | PROPOSED SCOPE OF WORK EXCEEDS 50 PERCENT OF THE VALUE | | | OF THE EXISTING STRUCTURE, THE SITE SHALL BE BROUGHT | | | INTO COMPLIANCE WITH ARTICLE XIV (LANDSCAPING) OF THE | | | ZLDRS. PLANS SHALL BE SUBMITTED INDICATING SUCH. IF | | | EXISTING MATERIAL IS SHOWN ON THE PLANS AND ALL | | | PROVISIONS OF ARTICLE XIV HAVE BEEN MET, THEN NO | | | ADDITIONAL PERMIT/INSTALLATION IS REQUIRED. IF THE | | | EXISTING MATERIAL ON SITE DOES NOT CONFORM TO ALL OF | | | THE REQUIREMENTS OF ARTICLE XIV, THEN ADDITIONAL | | | MATERIAL WILL NEED TO BE SHOWN ON THE PLANS AND | | | PERMITTED UNDER A LANDSCAPE PERMIT. PLEASE NOTE THAT | | | PLANS SHOULD INCLUDE, BUT NOT BE LIMITED TO, THE | | | FOLLOWING: | | | | | | A. THE LOCATION OF ALL EXISTING AND PROPOSED | | | STRUCTURES, IMPROVEMENTS, ETC. | | | | | | B. THE LOCATION OF ALL EXISTING AND PROPOSED TREES, | | | SHRUBS, GROUND COVERS, ETC. | | | | | | C. THE LOCATION OF UTILITY AND DRAINAGE EASEMENTS, | | | OVERHEAD LINES, WATER METERS, TRANSFORMERS, CHECK | | | VALVES, CLEAN OUTS, FIRE HYDRANTS, LIGHT POLES, ETC. | | | THAT MAY IMPACT LANDSCAPING. | | | | | | D. TABULATION TABLE INDICATING HOW THE EXISTING AND | | | PROPOSED PLANT MATERIAL COMPLIES WITH ARTICLE XIV. | | | | | | E. SPECIES, QUANTITY, HEIGHT, SPREAD, SPACING, AND | | | LOCATION OF THE EXISTING AND PROPOSED PLANT MATERIAL. | | | | | | F. STATEMENT THAT ALL LANDSCAPE AREAS WILL BE PROVIDED | | | WITH A PERMANENT AUTOMATIC IRRIGATION SYSTEM, INCLUDING | | | THE ADJACENT RIGHT-OF-WAY (PLEASE NOTE THAT ANY NEW | | | IRRIGATION SHALL BE DONE UNDER A SEPARATE PERMIT). | | | | | | 2. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, A MINOR | | | PLANNED DEVELOPMENT (PD) AMENDMENT SHALL BE APPROVED BY | | | THE PLANNING DIVISION. THIS APPLICATION HAS ALREADY | | | BEEN SUBMITTED ON BEHALF OF THE PROPERTY OWNER BY DARYL | | | JOHNSON, OF CORPORATE PROPERTY SERVICES, INC. HOWEVER, | | | COMMENTS WERE ISSUED ON JUNE 2, 2014, WHICH NEED TO BE | | | ADDRESSED BEFORE AN APPROVAL CAN BE ISSUED. A COPY OF | | | THE COMMENTS HAVE BEEN PROVIDED BELOW: | | | | | | A. PURSUANT TO THE DEVELOPEMNT APPLICATION AND SECTION | | | 94-448(D)(2)R. OF THE CITY?S ZONING AND LAND | | | DEVELOPMENT REGULATIONS, A LANDSCAPE PLAN SHALL BE | | | SUBMITTED. SUCH PLANS SHALL BE PREPARED BY A REGISTERED | | | LANDSCAPE ARCHITECT. | | | | | | B. PLEASE PROVIDE AN OVERALL SITE PLAN THAT INCLUDES | | | ALL INFORMATION CONTAINED WITHIN THE SITE PLAN | | | CHECKLIST, AS PROVIDED WITHIN THE DEVELOPMENT | | | APPLICATION. IMPORTANTLY, THE SITE PLAN SHALL INCLUDE A | | | DATA TABLE THAT INDICATED TOTAL ACRES OF THE PROJECT; | | | GROSS BUILDING SQUARE FOOTAGE; PERCENTAGE OF OPEN | | | SPACE, LANDSCAPING, BUILDING COVERAGE, AND IMPERMEABLE | | | SURFACE; PARKING COMPUTATIONS; AND FLOOR AREA RATIO | | | (FAR). | | | | | | C. THE PARKING STRIPING DETAIL ON THE SUBMITTED PLANS | | | IS INCORRECT. PLEASE EMAIL ME TO OBTAIN A COPY OF THE | | | STRIPING DETAIL. | | | | | | D. THERE SHOULD BE A MINIMUM OF FIVE (5) FEET BETWEEN | | | THE OUTDOOR PATIO AND THE PROPERTY LINE ALONG HANK | | | AARON DRIVE. | | | | | | E. PLEASE CLARIFY AS TO WHETHER OR NOT THE OUTDOOR | | | PATIO AREA WILL CONTAIN SEATING. IF SO, THE SEATING | | | SHALL BE ACCOUNTED FOR IN THE PARKING REQUIREMENTS. | | | | | | F. PLEASE PROVIDE DIMENSIONS OF THE PROPOSED SIGNAGE. | | | OF CONCERN IS ALSO THE NUMBER OF SIGNS. PURSUANT TO | | | ORDINANCE NO. 3844-05, WHICH GOVERNS THE HOME DEPOT | | | COMMERCIAL PLANNED DEVELOPMENT (CPD), BUILDINGS ARE | | | ONLY PERMITTED ONE (1) SIGN ON EACH OF THE FRONT, REAR, | | | AND SIDE FACADES. ORDINANCE NO. 3844-05 ALSO GOVERNS | | | THE MAXIMUM SIZE OF THE SIGNS. PLEASE EMAIL ME TO | | | OBTAIN A COPY OF THE ORDINANCE. | | | | | | G. STAFF WOULD LIKE TO WORK WITH THE APPLICANT | | | REGARDING THE NEED TO INSTALL AND/OR REPLACE LANDSCAPE | | | MATERIAL THROUGHOUT THE PROPERTY TO BRING IT INTO | | | COMPLIANCE WITH THE APPROVED LANDSCAPE PLAN FOR THE | | | SITE. PLEASE EMAIL ME FOR A COPY OF THE APPROVED | | | LANDSCAPE PLAN. ALL MATERIAL SHOWN ON THE PLAN SHALL BE | | | PRESENT ON THE PROPERTY. ANY MISSING MATERIAL NEEDS TO | | | BE INSTALLED, OR ANY CHANGES TO THE PLAN NEED TO BE | | | APPROVED THROUGH THE MINOR AMENDMENT. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | | | 2014-05-21 14:32:11 | 5/21/14 |
|
|
|