| Plan Review Stops For Permit 14050451 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-07-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-07-10 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-07-10 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2014-07-10 07:38:43 | I HAVE MARKED, REDLINED, THE WINDOW SCHEDULE TO | | | INDICATE IMPACT GLASS IS PROPOSED BY WAY OF THE WINDOW | | | PRODUCT SUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-06-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-06-10 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-06-10 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2014-06-10 17:18:35 | 2ND REVIEW: | | | | | | THE FIRST REVIEW COMMENT TO SUBMIT PRODUCT APPROVAL | | | REVIEWED BY THE DESIGN PROFESSIONAL OF RECORD IS | | | RECINDED AS THIS DESIGN IS NOT SEALED BY A REGISTERED | | | DESIGN PROFESSIONAL. HOWEVER, PER FBC 107.3.5.3 | | | RESIDENTIAL (ONE AND TWO-FAMILY) MINIMUM PLAN REVIEW | | | CRITERIA, THE PRODUCTS PROPOSED TO BE USE ARE REQUIRED | | | TO BE SUBMITTED AND MUST BE CONSISTANT WITH THE | | | PROVIDED DESIGN. THE SECOND SUBMITTAL INCLUDED AN | | | IMPACT WINDOW AND A NON IMPACT WINDOW PRODUCT AND NO | | | SHUTTER PRODUCT. THE PLAN WINDOW SCHEDULE INDICATES | | | SHUTTERS ARE TO BE INSTALLED, AND THAT MULLS ARE | | | REQUIRED TO JOIN SOME OF THE WINDOWS TOGETHER. PLEASE | | | CLARIFY THE WINDOW PRODUCT TO BE USED AND PROVIDE A | | | PRODUCT APPROVED MULLION. IF SHUTTERS ARE TO BE USED, | | | PROVIDE THAT PRODUCT., IF NOT, CORRECT THE PLAN TO NOT | | | INDICATE SHUTTERS. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-05-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-16 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-16 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2014-05-16 14:09:03 | 1ST REVIEW: | | | | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. | | | WHOMEVER FROM M&I DESIGNS INC. RESPONSIBLE FOR THIS | | | DESIGN MUST COMPLY WITH THE FOREGOING. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW, SHUTTERS AND DOOR | | | SUBMITTALS. | | | WHOMEVER FROM M&I DESIGNS INC. RESPONSIBLE FOR THIS | | | DESIGN IS THE DESIGNER OF RECORD AND SHOULD APPROVE IN | | | WRITING THE PRODUCT APPROVALS YET TO BE SUBMITTED. | | | | | | FBC 107.3.5.1.6 ENERGY CALCULATIONS - PROVIDE AN ENERGY | | | SUBMITTAL COMPLIANT WITH FBC-E 103 AS THE IMPROVEMENTS | | | EXCEED 30% OF THE VALUE OF THE STRUCTURE. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-05-16 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-05-16 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-05-16 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2014-05-16 12:29:42 | SENT TO SAK DESK PER REQUEST. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-07-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-07-10 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-07-07 |
Time |
07:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-06-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-06-10 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-06-09 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2014-06-10 11:18:12 | TO SK DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-05-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-16 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-13 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2014-05-15 13:59:03 | SENT TO R20 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2014-07-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-07-10 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-07-10 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2014-06-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-06-10 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-06-10 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2014-06-10 17:41:31 | 2ND REVIEW: | | | | | | FBC-R-M 1602.4 PROVIDE BALANCED AIR RETURN AT BEDROOMS. | | | | | | THE UPDATED MECHANICAL PLAN DOES NOT ADEQUATELY DEPICT | | | COMPLIANCE WITH THE FORGOING SECTION. PLEASE EITHER | | | UPDATE THE PLAN OR IN THE EVENT YOU HIRE A LICANSED | | | MECHANICAL CONTRACTOR, ELECT TO SUBMIT A REVISION AS | | | BUILT BY THE MECHANICAL CONTRACTOR. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-05-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-16 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-16 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2014-05-16 13:29:10 | 1ST REVIEW: | | | | | | THE PLAN REFERENCES THE 2007 FLORIDA BUILDING CODE AS | | | THE CODE IN EFFECT. PLEASE REVISE TO THE ACTUAL CODE IN | | | EFFECT WHICH IS 2010. THIS IS IN THE MECHAAANICAL | | | GENERAL NOTES AND ON PAGE 6. | | | | | | PER FBC-R-M 1602.4 PROVIDE BALANCED AIR RETURN AT | | | BEDROOMS. | | | | | | INDICATE THE R-VALUE PROPOSED FOR THE DUCT SYSTEM, | | | PLEASE NOTE THE MINIMUM PERSCRIPTIVE VALUE IS R-6 PER | | | FBC-EC:T402.1.1 | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-05-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-16 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-16 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|