| 2014-05-24 06:14:22 | BUILDING PLAN REVIEW |
| | REVISION: 13120383 |
| | ADD: 14050357 |
| | CONT: 401 S DIXIE HWY |
| | TEL: (561)307-4951 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: SAT. MAY 24/ 2014 |
| | ACTION: DENIED |
| | |
| | 1) THIS PERMIT IS FOR 3RD FLOOR CORRIDOR AND COMMON |
| | AREA RESTROOMS. THE REVISED SCOPE OF WORK GOES BEYOND |
| | THE ORIGINAL SCOPE OF WORK WITH ADDING 3 PAIRS OF |
| | DOUBLE DOORS AND NEW TENANT DEMISSING WALLS SPLITTING |
| | SUITE # 301 INTO 2 SUITES, REPLACEMENT OF PLUMBING |
| | FIXTURES IN BOTH RESTROOMS WITH OUT THE INCREASE IN THE |
| | VALUE OF WORK . |
| | |
| | W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES. |
| | ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL, |
| | AND PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT, |
| | A FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN |
| | ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE |
| | APPLICABLE GOVERNING AUTHORITY. |
| | |
| | 108.3* BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 2) SHEET A-1.0 REVISION # 2 THE NEW WALL CONFIGURATION |
| | IN THE CORRIDOR AS WELL AS THE NEW TENANT FIRE |
| | PARTITION DOES NOT PROVIDE WALL IDENTIFICATION TAGS |
| | IDENTIFYING WHICH OF THE PARTITION DETAILS FOUND ON |
| | A-2.0 WILL BE USED IN CONSTRUCTING THESE WALLS. PLEASE |
| | PROVIDE THIS ADDITIONAL INFORMATION 2010 WEST PALM |
| | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER |
| | 1, ADMINISTRATION, 107.2.1.3. 2010 FBC-B 709.1.6 AND |
| | 709.4 CONTINUITY, 1018.1 CORRIDOR FIRE RESISTANCE AND |
| | 1018.6 CONTINUITY. |
| | |
| | 3) SHEET A-1.1 IN SUITE # 301 BEHIND THE NEW DOUBLE |
| | DOORS THERE APPEARS TO BE A VERTICAL DUCT AND NEW |
| | SHAFT, PLEASE PROVIDE ADDITIONAL INFORMATION AS IF THIS |
| | IS A NEW SHAFT AND IF SO THE FIRE RATING ON THE SHAFT, |
| | CONFIGURATION OF THE COMPONENTS THAT MAKE UP THE SHAFT |
| | WALL ASSEMBLY. 2010 FBC-B 708.2 SHAFT ENCLOSURES |
| | REQUIRED. |
| | |
| | 4) SHEET A-1.1 IN SUITE # 301 THE PLANS SHOW A EXIT |
| | LIGHT (FBC-B 1006.3.1) AND EMERGENCY BATTERY BACK-UP |
| | LIGHT (FBC-B TABLE 1006.1) , IN SUITE # 305 THE PLANS |
| | ARE MISSING THE EXIT LIGHT AS WELL AS THE EMERGENCY |
| | BATTERY BACK UP LIGHT. |
| | |