Plan Review Details - Permit 14050273
Plan Review Stops For Permit 14050273
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-05-30 Cont ID  
Sent By skennedy Date 2014-05-30 Time 06:54 Rev Time 0.00
Received By skennedy Date 2014-05-30 Time 06:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-05-18 Cont ID  
Sent By skennedy Date 2014-05-18 Time 09:14 Rev Time 0.00
Received By skennedy Date 2014-05-18 Time 09:14 Sent To  
Notes
2014-05-18 09:23:081ST REVIEW:
  
 1) FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY
 DCA RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, GARAGE DOOR
 SUBMITTALS. GARAGE DOOR IS MISSING, OTHERS OK.
  
 2) FBC 107.3.5.3 ? PROVIDE A SITE PLAN TO DEMONSTRATE
 SETBACKS AND BUILDING SEPARATION. THE SITE PLAN AND
 SURVEY PROVIDED DO NOT MATCH.
  
 3) FBC-110.7 SUPPLY A DRAINAGE DESIGN. NEW CONSTRUCTION
 ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL HISTORIC
 SURFACE WATER DRAINAGE FLOWS SERVING ADJACENT
 PROPERTIES, AND MAY REQUIRE SPECIAL DRAINAGE DESIGN
 COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE DRAINAGE PATTERNS OF THE AFFECTED SITES.
  
 4) FBC 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE
 OPINION OF THE BUILDING OFFICIAL, THE CLAIMED VALUATION
 OF BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS
 (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE
 BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING,
 MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK,
 ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 I REASSESSED THE VALUE AT $533,244.84 USING THE
 INTERNATIONAL CODE CONGRESS BUILDING VALUE DATED
 PUBLISHED 02/14.
  
 NOTE: FLOOD ZONE REVIEW IS PENDING.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2014-05-30 Cont ID  
Sent By dhayes Date 2014-05-30 Time 07:47 Rev Time 0.00
Received By dhayes Date 2014-05-30 Time 07:47 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2014-05-27 Cont ID  
Sent By dhayes Date 2014-05-27 Time 16:52 Rev Time 0.00
Received By dhayes Date 2014-05-27 Time 16:52 Sent To B
Notes
2014-05-27 16:04:222ND ELECTRICAL REVIEW DENIED. THE ELECTRICAL SYSTEM IS
 STILL FOUND TO BE DEFICIENT IN THE FOLLOWING AREAS
 BASED ON 2008 EDITION OF THE NEC AND THE 2010 FBC. SEE
 COMMENTS BELOW:
  
 1) GROUNDING ELECTRODE CONDUCTOR IS IMPROPERLY SIZED
 250.66, THE GROUNDING ELECTRODE CONDUCTOR FOR A 300AMP
 SERVICE IS REQUIRED TO BE A #2CU MINIMUM.
  
 2) AN INTERSYSTEM BOND STRIP IS REQUIRED PER 250.94
  
 3) ALL 125V SINGLE PHASE, 15 AND 20AMP RECEPTACLES
 INSTALLED IN THE LOCATIONS SPECIFIED IN (1) THROUGH (8)
 SHALL HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION
 FOR PERSONNEL. NEC 210.8. ALL OUTLETS IN THE GARAGE
 SHALL BE GFCI PROTECTED. INCLUDING THE GARAGE DOOR
 OPENERS.
  
 4) RECEPTACLES SHALL BE SPACED SO THAT AT NO POINT
 ALONG THE FLOOR IN ANY WALL IS MORE THAN 6 FEET FROM A
 RECEPTACLE OUTLET. NEC 210.52 (A)(2).
 THERE ARE SEVERAL AREAS THROUGHOUT THE HOME TO BE
 ADDRESSED. THIS INCLUDES FIXED PANELS. "THE SPACE
 OCCUPIED BY FIXED PANELS IN EXTERIOR WALLS, EXCLUDING
 SLIDING PANELS"
  
 7) IF THE RESIDENCE HAS GAS APPLIANCES, AN ATTACHED
 GARAGE OR A FIRE PLACE A CARBON MONOXIDE DETECTOR IS
 REQUIRED WITHIN TEN FEET OF EACH ROOM USED FOR
 SLEEPING. FBC R314, 315
  
 NOTE: SEPARATE PERMITS ARE REQUIRED FOR THE POOL, AND
 DOCK.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR AT [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-05-19 Cont ID  
Sent By dhayes Date 2014-05-19 Time 14:26 Rev Time 0.00
Received By dhayes Date 2014-05-19 Time 12:45 Sent To  
Notes
2014-05-19 14:22:37ELECTRICAL REVIEW DENIED. THE ELECTRICAL SYSTEM IS
 FOUND TO BE DEFICIENT IN THE FOLLOWING AREAS BASED ON
 2008 EDITION OF THE NEC AND THE 2010 FBC, FBC RES., FBC
 ENERGY, SEE COMMENTS BELOW.
  
 1) ELECTRICAL SERVICE RISER INDICATES A 300AMP
 DISCONNECT SWITCH WITH A 2/0 FEEDER. THE MINIMUM SIZE
 SERVICE ENTRANCE CONDUCTOR FOR A RESIDENTIAL SERVICE
 ENTRANCE OR FEEDER IS A 250MCM CU. OR 350MCM AL.
  
 2) THE DESIGN OF THE ELECTRICAL SERVICE RISER IS NOT IN
 COMPLIANCE WITH NEC 310.15(B)(6), 240.21. PLEASE SHOW
 OVER CURRENT PROTECTION AND APPROPRIATE FEEDER SIZE FOR
 SUB-PANEL "B"
  
 3) GROUNDING ELECTRODE CONDUCTOR APPEARS TO BE
 IMPROPERLY SIZED FOR BONDING OF ALL SYSTEMS AND PROVIDE
 BONDING OF ALL SYSTEMS AND BUILDING STEEL, AS
 APPLICABLE 250.66, 250.104THE GROUNDING ELECTRODE
 CONDUCTOR FOR A 300AMP SERVICE IS REQUIRED TO BE A #2CU
 MINIMUM.
  
 4) AN INTERSYSTEM BOND STRIP IS REQUIRED PER 250.94
  
 5) ALL 125V SINGLE PHASE, 15 AND 20AMP RECEPTACLES
 INSTALLED IN THE LOCATIONS SPECIFIED IN (1) THROUGH (8)
 SHALL HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION
 FOR PERSONNEL. NEC 210.8. ALL OUTLETS IN THE GARAGE
 SHALL BE GFCI PROTECTED.
  
 6) LUMINAIRES IN CLOTHES CLOSETS. ARTICLE 410.16 (C)(3)
 LOCATION. STATES IN PART , THE MINIMUM CLEARANCE
 BETWEEN LUMINAIRES INSTALLED IN CLOTHES CLOSETS AND THE
 NEAREST POINT OF A STORAGE SPACE SHALL BE AS FOLLOWS:
 "150MM (6") FOR RECESSED INCANDESCENT OR LED LUMINAIRES
 WITH A COMPLETELY ENCLOSED LIGHT SOURCE INSTALLED IN
 THE WALL OR CEILING" OR (4) "150MM (6") FOR RECESSED
 FLUORESCENT LUMINAIRES INSTALLED IN THE WALL OR
 CEILING." PLEASE INDICATE COMPLIANCE WITH THIS SECTION
 OF THE NEC WHERE INSTALLING RECESSED LIGHTING IN
 CLOTHES CLOSETS
  
 7) RECEPTACLES SHALL BE SPACED SO THAT AT NO POINT
 ALONG THE FLOOR IN ANY WALL IS MORE THAN 6 FEET FROM A
 RECEPTACLE OUTLET. NEC 210.52 (A)(2).
 THERE ARE SEVERAL AREAS THROUGHOUT THE HOME TO BE
 ADDRESSED.
  
 8) RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED. AT
 LEAST 50% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHT
 FIXTURES SHALL BE HIGH EFFICIENCY. FBC-R 402.4.5, &
 404.1,
  
 9) ALL NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC
 406.11 THOSE OUTLETS IN WET LOCATIONS SHALL BE WEATHER
 RESISTANT NEC 406.8(B)(1)
  
 10) OCCUPIABLE BALCONIES AND PORCHES OVER 20 SQ FT MUST
 HAVE A RECEPTACLE OUTLET GFCI PROTECTED. NEC
 210.52(E)(3).
  
 11) IN KITCHENS, PANTRIES, BREAKFAST ROOMS, DINING
 ROOMS, AND SIMILAR AREAS OF DWELLING UNITS, RECEPTACLE
 OUTLETS FOR COUNTERTOP SPACES SHALL BE INSTALLED IN
 ACCORDANCE WITH NEC 210.52(C)(1) THROUGH (C)(5).
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR AT [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-05-30 Cont ID  
Sent By dhayes Date 2014-05-30 Time 07:47 Rev Time 0.00
Received By dhayes Date 2014-05-30 Time 06:57 Sent To E
Notes
2014-05-30 06:58:27TO DAH DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-05-30 Cont ID  
Sent By skennedy Date 2014-05-30 Time 06:57 Rev Time 0.00
Received By skennedy Date 2014-05-23 Time 11:02 Sent To Z
Notes
2014-05-27 11:04:00PLEASE FORWARD TO DAVID HAYES DESK WHEN COMPLETE.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-05-19 Cont ID  
Sent By dhayes Date 2014-05-19 Time 14:26 Rev Time 0.00
Received By dhayes Date 2014-05-07 Time 07:07 Sent To  
Notes
2014-05-08 07:07:24R22

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2014-05-30 Cont ID  
Sent By skennedy Date 2014-05-30 Time 06:37 Rev Time 0.00
Received By skennedy Date 2014-05-30 Time 06:33 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-05-18 Cont ID  
Sent By skennedy Date 2014-05-18 Time 08:25 Rev Time 0.00
Received By skennedy Date 2014-05-18 Time 08:25 Sent To  
Notes
2014-05-18 08:26:02IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED.
 AFTER APPROVAL, A SET OF THE PLANS ARE TO BE CHECKED
 OUT AND TAKEN TO THE PBC IMPACT FEE OFFICE, STAMPED BY
 THAT OFFICE, AND RETURNED WITH A RECEIPT PROVIDED.
 CONTACT 561 233 5100.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-05-30 Cont ID  
Sent By skennedy Date 2014-05-30 Time 06:47 Rev Time 0.00
Received By skennedy Date 2014-05-30 Time 06:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-05-18 Cont ID  
Sent By skennedy Date 2014-05-18 Time 09:04 Rev Time 0.00
Received By skennedy Date 2014-05-18 Time 08:37 Sent To  
Notes
2014-05-18 09:04:281ST REVIEW:
  
 1) FBC-R-M 1602.4 PROVIDE BALANCED AIR RETURN AT THE
 MASTER BEDROOM I DO NOT SEE A RAG OR JUMPER FOR THIS
 ROOM ON THE PLAN.
  
 2) FBC-EC 403.2.5 PROVIDE A SIZING CALCULATION: PRVIDE
 A SIZING CALCULATION THAT IS CONSISTENT WITH THE
 INFORMATION ON THE PLAN. THE MANUAL J MODEL NUMBER FOR
 SYSTEM 2 DOES NOT MATCH THAT SPECIFIED UPON THE PLAN.
 PROVIDE THE SENSIBLE AND LATENT COOLING CAPACITY ON THE
 EQUIPMENT SCHEDULE FOR EACH SYSTEM ON THE PLAN.
  
 3) FBC-R M1305.1.3 APPLIANCES IN ATTICS. INDICATE ON
 THE PLAN THE FOLLOWING, PARTICULARLY THE INTENT TO
 PROVIDE SOLID DECKING: ATTICS CONTAINING APPLIANCES
 SHALL BE PROVIDED WITH AN OPENING AND A CLEAR AND
 UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO ALLOW REMOVAL
 OF THE LARGEST APPLIANCE, BUT NOT LESS THAN 30 INCHES
 (762 MM) HIGH AND 22 INCHES (559 MM) WIDE AND NOT MORE
 THAN 6 FEET (1829 MM) LONG MEASURED ALONG THE
 CENTERLINE OF THE PASSAGEWAY FROM THE OPENING TO THE
 APPLIANCE. THE PASSAGEWAY SHALL HAVE CONTINUOUS SOLID
 FLOORING IN ACCORDANCE WITH CHAPTER 5 NOT LESS THAN 24
 INCHES (610 MM) WIDE. A LEVEL SERVICE SPACE AT LEAST 30
 INCHES (762 MM) DEEP AND 30 INCHES (762 MM) WIDE SHALL
 BE PRESENT ALONG ALL SIDES OF THE APPLIANCE WHERE
 ACCESS IS REQUIRED. THE CLEAR ACCESS OPENING DIMENSIONS
 SHALL BE A MINIMUM OF 20 INCHES BY 30 INCHES (508 MM BY
 762 MM), AND LARGE ENOUGH TO ALLOW REMOVAL OF THE
 LARGEST APPLIANCE.
  
 4) FBC-R M1305.1.3.1 ELECTRICAL REQUIREMENTS.
 A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE
 REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET
 SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN
 ACCORDANCE WITH CHAPTER 34.
  
 5) INDICATE UPON THE PLAN COMPLIANCE WITH #2 & #3
 BELOW:
 FBC-R M1305.1.3.2 AIR-HANDLING UNITS AIR-HANDLING UNITS
 SHALL BE ALLOWED IN ATTICS IF THE FOLLOWING CONDITIONS
 ARE MET:
 1. THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN
 6 FEET (1829 MM) OF AN ATTIC ACCESS.
 2. A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT THE
 UNIT DOWN WHEN THE CONDENSATION DRAIN IS NOT WORKING
 PROPERLY.
 3. THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO
 REPLACE THE AIR HANDLER
 4. A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL
 INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS
 LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL
 CAPITALS, IN 16 POINT TYPE, WITH THE TITLE AND FIRST
 PARAGRAPH IN BOLD:
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
  
  
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-05-30 Cont ID  
Sent By skennedy Date 2014-05-30 Time 06:39 Rev Time 0.00
Received By skennedy Date 2014-05-30 Time 06:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-05-18 Cont ID  
Sent By skennedy Date 2014-05-18 Time 09:04 Rev Time 0.00
Received By skennedy Date 2014-05-18 Time 08:15 Sent To  
Notes
2014-05-18 08:37:261ST REVIEW:
  
 1) THE PLUMBING RISER DOES NOT MATCH THE SECOND FLOOR
 PLAN. PLAN SHOWS A BATHROOM GROUP THAT IS NOT REFLECTED
 IN THE RISER.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2014-05-30 Cont ID  
Sent By skennedy Date 2014-05-18 Time 10:10 Rev Time 0.00
Received By skennedy Date 2014-05-18 Time 10:10 Sent To  
Notes
2014-05-18 10:11:11ROOFING

Review Stop Z ZONING
Rev No 2 Status P Date 2014-05-27 Cont ID  
Sent By skennedy Date 2014-05-30 Time 06:57 Rev Time 0.00
Received By sgraham Date 2014-05-27 Time 15:11 Sent To E
Notes
2014-05-27 15:11:285/27/14 ZONING PROVISO:
  
 SUBMIT SEPARATE PLAN FOR THE DRIVEWAY AND LANDSCAPING.
 THE APPROACH CAN NOT BE 25',CONTACT MANNY GONZALES AT
 561-494-1050 TO GET THE ALLOWABLE ON DRIVEWAYS.

Review Stop Z ZONING
Rev No 1 Status F Date 2014-05-19 Cont ID  
Sent By sgraham Date 2014-05-19 Time 08:29 Rev Time 0.00
Received By sgraham Date 2014-05-19 Time 08:29 Sent To E
Notes
2014-05-19 08:29:495/19/14 ZONING FAILED.
  
 1. SURVERY AND PLOT PLAN MUST MATCH, PLEASE SUBMIT 2-
 SURVERYS AND 2- PLOT PLANS THAT MATCH.
2014-05-12 17:25:425/12/14